Description
1. Introduction
The spinal needle introducers from B. Braun are the ideal insertion guide for working with fine intradural needles from the Spinocan®, Atraucan® and Pencan® families. Their main function is to pierce the skin and superficial layers in a controlled manner, protecting the delicate cannula of the spinal needle during puncture and significantly improving tactile sensitivity and the anaesthetist’s precision when accessing the subarachnoid space.
It is a sterile single-use consumable, supplied in a box of 25 units, intended for anaesthesiology services, operating theatres, pain units and diagnostic lumbar puncture centres.
2. Technical explanation of the procedure
In spinal or intrathecal anaesthesia, fine-gauge needles (25G to 29G) require a firm entry point to avoid deviation or bending when piercing the skin and ligaments. The introducer acts as a shorter, larger-gauge guide cannula that is inserted first: once positioned, the intradural needle is advanced through its lumen until reaching the subarachnoid space, reducing tissue trauma and facilitating the characteristic dural ‘click’.
The compatibility of the introducer depends on the needle diameter: the 22G (0.70 mm) model accepts spinal needles of 27G–29G, while the 20G (0.90 mm) model is indicated for needles of 25G–26G. Both feature a facet bevel for clean penetration, elliptical hub and identification colour (transparent for the 22G and yellow for the 20G), facilitating immediate identification of the material in the sterile field.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Brand / Manufacturer | B. Braun (B. Braun Melsungen AG) |
| Product type | Introducer for spinal needle (introducer needle) |
| Compatibility | Spinal needles Spinocan®, Atraucan® and Pencan® |
| Bevel type | Facet |
| Connector design | Elliptical |
| Packaging | Individual blister |
| Use | Single-use |
| Sterility | Sterile |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 25 units |
| Contains PVC / Latex / DEHP | No / No / No |
Available references
| Reference | Model | Gauge (G) | Outer diameter | Length | Colour | For use with |
|---|---|---|---|---|---|---|
| 4500059-13 | Introducer (0.7 × 35 mm) 22G × 1 3/8\” | 22 | 0.70 mm | 35 mm (1 3/8\”) | Transparent | Spinal needles 29G and 27G |
| 4505000-13 | Introducer (0.9 × 35 mm) 20G × 1 3/8\” | 20 | 0.90 mm | 35 mm (1 3/8\”) | Yellow | Spinal needles 26G and 25G |
Corresponding B. Braun catalogue tariff coding: 254500059-13 (22G × 35 mm introducer) and 254505000-13 (20G × 35 mm introducer).
4. Equivalences and Cross-References
B. Braun does not publish an official cross-reference table for spinal needle introducers; its internal coding relates the commercial references 4500059-13 and 4505000-13 to the tariff codes 254500059-13 and 254505000-13, respectively.
These introducers are supplied as standard, either as a spare or included, with the following spinal needles from the Cahnos catalogue: Pencan® 27G × 88 mm with introducer (Ref. 4502051-13), Pencan® 25G × 88 mm with introducer (Ref. 4502043-13), Pencan® 27G × 103 mm with introducer (Ref. 4502124-13), Pencan® 25G × 103 mm with introducer (Ref. 4502116-13) and Spinocan® 29G × 88 mm with introducer (Ref. 4501900-13). The 22G × 35 mm introducer (254500059-13) is associated with 29G and 27G needles; the 20G × 35 mm (254505000-13) with 26G and 25G needles.
No verified equivalents are available for loose introducers from other manufacturers (e.g., BD or Dahlhausen), as these are usually marketed integrated into the packaging of each spinal needle or under their own unpublished coding. Before substituting in a tender, verify gauge, length, bevel type, compatibility with the needle diameter and sterility of the actual product.
5. Selection tips and variants of interest
Gauge selection: choose the 22G (0.70 mm) introducer for spinal needles of 27G and 29G (the finest) and the 20G (0.90 mm) for needles of 25G and 26G. Always use the guide diameter appropriate to the needle to ensure correct sliding and maintain tactile control of the puncture.
Routine use: in spinal anaesthesia techniques with fine needles or atraumatic pencil-point (Pencan®), the introducer is highly recommended to minimise cannula deflection and reduce trauma to superficial tissues, favouring a more atraumatic and comfortable approach for the patient.
Associated variants: in the Cahnos catalogue you have the compatible Pencan® spinal needles with and without introducer (Ref. 4502051-13, 4502043-13, 4502124-13, 4502116-13 and 4502027-01, among others) and the Spinocan® range with Quincke bevel (including the version with introducer for 29G, Ref. 4501900-13). Verify the integrity of the sterile packaging before each use and dispose of the material after a single puncture in an approved container for healthcare waste. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos.







Reviews