Description
1. Introduction
The Perifix® Paediatric Trays from B. Braun are complete, sterile systems designed for continuous epidural anaesthesia in paediatric patients with maximum safety and comfort. Each tray brings together the essential components (needle, catheter, connector, filter and syringes) manufactured in sizes specific to newborns, infants and school-age children, simplifying work station preparation, reducing times and minimising the risk of errors during the procedure. They are especially indicated for anaesthesiology departments, paediatric surgery and children’s pain units.
2. Technical explanation of the procedure
In paediatric epidural anaesthesia, the puncture is performed with a Perican® epidural needle with a Tuohy bevel, whose design allows the epidural space to be located using the loss of resistance technique, assisted by the Perifix® LOR syringe included in the tray. The Perifix® ONE epidural catheter is introduced through the needle, manufactured with a polyamide core (rigidity necessary for easy insertion) and an outer polyurethane cover (softness for placement inside the body), with 6 lateral micro-orifices that favour uniform distribution of the local anaesthetic and a radiopaque marker for imaging control.
The system is completed with a crocodile-type catheter connector, tunnelled and threadless, with an ergonomic, flat profile, and a flat Perifix® 0.2 µm filter that retains particles and microorganisms, placed between the infusion line and the catheter connector. The filter is fixed to the patient’s skin using the Perifix® PinPad, a hypoallergenic adhesive base that allows secure anchoring and free rotation of the filter, facilitating drug administration and daily skin hygiene.
3. Technical Specifications
Data verified according to the manufacturer’s official catalogue (B. Braun Melsungen AG).
Available references (sold in boxes of 10 units):
| Reference | Model | Epidural needle | Needle length | Catheter | Catheter length | Catheter diameter (ext./int.) | Filter | Max. pressure | Syringe included | PinPad |
|---|---|---|---|---|---|---|---|---|---|---|
| 4512006C | PERIFIX ONE PAED 18 | 18 G, Tuohy bevel, graduated every 0.5 cm | 50.00 mm | ONE 20 G | 1000 mm | 0.85 / 0.45 mm | 0.2 µm (0.70 ml) | 7.0 bar | 1 x Omnifix 2 ml Luer-Lock + 1 x Perifix LOR | Yes |
| 4512014C | PERIFIX ONE PAED 20 | 20 G, Tuohy bevel, graduated every 0.5 cm | 50.00 mm | ONE 24 G | 720 mm | 0.60 / 0.35 mm | 0.2 µm (0.70 ml) | 7.0 bar | 1 x Omnifix 2 ml Luer-Lock + 1 x Perifix LOR | Yes |
Composition of the tray:
- Perican® epidural needle: Tuohy bevel, markings every 0.5 cm, transparent hub with integrated wings and coloured stylet; diameter 1.30 x 50 mm (18 G, for 20 G catheters) or 0.90 x 50 mm (20 G, for 24 G catheters).
- Perifix® ONE epidural catheter: polyamide and polyurethane; length 720 mm (24 G) or 1000 mm (20 G); 3 pairs of lateral micro-holes; markings between 20 mm and 200 mm; introducer guide.
- Perifix® catheter connector: crocodile type, tunnelled and threadless; ergonomic and flat.
- Perifix® flat 0.2 µm filter: small, rounded and ergonomic; filling capacity 0.45 ml; priming volume 0.70 ml; resistance up to 7 bar.
- Perifix® PinPad: exclusive fixation system for the flat Perifix® 0.2 µm filter with hypoallergenic adhesive.
- Perifix® LOR syringe: 3-part syringe with excellent sensitivity; Luer Slip cone.
- Omnifix® Luer-Lock syringes: 3-part; 2 ml.
General characteristics:
| Property | Value |
|---|---|
| Brand / Manufacturer | B. Braun (B. Braun Melsungen AG) |
| Family | Perifix® (regional anaesthesia) |
| Product type | Epidural set (tray) |
| Application | Epidural — paediatric population |
| Packaging | Blister |
| Contains PVC | No |
| Contains latex | No |
| Contains DEHP | No |
| Use | Single-use |
| Sterility | Sterile |
| Sterilisation | EO (ethylene oxide) |
| Presentation | Box of 10 units |
4. Equivalences and Cross-References
The Perifix® Paediatric Trays belong to the closed Perifix® regional anaesthesia system from B. Braun. Within the same manufacturer, the variant with NRFit® safety connection (ISO 80369-6) are the Perifix® Paediatric NRFit® Trays (refs. 45120061N-01 and 45120141N-01); the system is completed with the Perifix® LOR NRFit® syringe (refs. 4638110 and 4637110), the Perifix® ONE catheter, the Perifix® PinPad (ref. 4515510) and the Perifix® trays and equipment for adults.
There is no 1:1 equivalence table validated by the manufacturer that would allow these trays to be replaced by sets from other manufacturers. On the market, the homologous families of paediatric epidural anaesthesia trays from Pajunk®, Vygon and ICU Medical/Portex® should be considered comparable at category level, not interchangeable reference by reference, and it is mandatory to verify in each brand’s technical data sheet the paediatric size, needle and catheter gauge, material, connection type and authorised target population before any substitution in a tender.
5. Selection tips and variants of interest
Select the reference according to the age and characteristics of the paediatric patient: the REF 4512006C (PERIFIX ONE PAED 18) incorporates an 18 G epidural needle with a 1000 mm Perifix® ONE 20 G catheter; the REF 4512014C (PERIFIX ONE PAED 20) incorporates a 20 G needle with a 720 mm Perifix® ONE 24 G catheter, of smaller diameter (0.60/0.35 mm), indicated for smaller patients. Assess the gauge according to the department’s protocol and the patient’s characteristics, and complete the system with other elements from the Perifix® range to maintain a safe epidural circuit.
These trays are distributed in boxes of 10 units and are marketed on quotation. To guarantee sterility, check the integrity of the blister before use; each tray is single-use and must not be re-sterilised. Consult the technical-commercial team at Cahnos for advice on sizes, quantities and supply conditions for the paediatric Perifix® range.