Conventional light bulb for small laryngoscope blade – Ø 3×14 mm, replacement (Ref. RIA53180 | SKU BRLRIA53180)

4,26 €

Conventional light bulb (Conventional Light) as original replacement for small resuscitation laryngoscope blades with classic bulb illumination. Its compact Ø 3×14 mm glass ensures a firm seat, correct filament alignment and stable, bright illumination at the visualisation point during direct laryngoscopy and orotracheal intubation. An economical and reliable replacement part to restore the light source of your equipment without replacing the handle or the complete blade; ideal for emergency, anaesthesia, ICU, operating theatre and emergency supplies. Manufacturer reference RIA53180 (SKU Cahnos BRLRIA53180). For large orders you can request a quote.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLRIA53180

You will also find it in

Description

1. Commercial Introduction

The conventional light bulb for small laryngoscope blades (ref. RIA53180) is the original replacement part indicated to keep resuscitation laryngoscopes with conventional illumination system and small blade (leaf) operational. It is a replacement part designed for hospitals, clinics, emergency services, anaesthesia, ICU and out-of-hospital emergency teams that need to replace the light source of their laryngoscopes quickly, reliably and economically, without having to replace the handle or the complete blade.

2. Technical Explanation

In conventional-light laryngoscopes, the bulb is housed in the blade (leaf) or in the handle and projects the illumination directly onto the visualisation field of the glottis during direct laryngoscopy. This compact bulb, with a Ø 3×14 mm body and conventional light socket, is designed specifically for the small laryngoscope blades in this range, ensuring a firm seat, correct filament alignment and a homogeneous, stable projection of the light beam. Replacement is simple and quick, which minimises clinical equipment downtime and ensures that the airway trolley is always ready for intubation and resuscitation.

3. Technical Specifications

Replacement conventional light bulb (Conventional Light) for small resuscitation laryngoscope blade, from the airway instrumentation catalogue.

Characteristic Specification
Manufacturer reference RIA53180
Reference Cahnos (SKU) BRLRIA53180
Manufacturer Boscarol
Product type Replacement conventional light bulb for laryngoscope
Compatibility Small laryngoscope blades (leaves) with conventional light system
Dimensions Ø 3×14 mm
Application Direct laryngoscopy, orotracheal intubation and resuscitation

Available references:

Reference Designation Sales unit
RIA53180 / BRLRIA53180 Conventional light bulb for small blade (Ø 3×14 mm) 1 unit

4. Equivalences and Cross-References

The reference RIA53180 corresponds to the manufacturer’s official coding and is sold on Cahnos under the SKU BRLRIA53180 (same product, dual coding). No 1:1 equivalence table validated by the manufacturer is available against bulbs from other brands (e.g. Heine, GIMA, Riester or KaWe); before replacing any bulb with a product from another manufacturer, the working voltage of the handle, the socket type and the diameter of the housing must be verified. The Cahnos catalogue includes complementary lighting spare parts in the range, such as the conventional bulb for large blade ref. RIA53182 (SKU BRLRIA53182, Ø 4×18 mm) and the fibre-optic bulbs ref. RIA53380 (SKU BRLRIA53380) for large handle and ref. RIA53382 (SKU BRLRIA53382) for small handle. Please consult our technical-commercial department to confirm compatibility with your configuration.

5. Selection tips and variants of interest

Check the blade: confirm that your laryngoscope uses a small blade with a conventional illumination system and that the Ø 3×14 mm bulb fits correctly in the housing, to ensure optimal optical alignment of the filament. If your equipment uses a large blade or a fibre-optic system, consider the replacement variants in the same range (RIA53182, RIA53380 and RIA53382). Handling: install the bulb with gloves or a clean, dry cloth; direct contact with fingers can damage the glass and shorten its service life. Spare parts stock: keep several replacement bulbs on the airway trolley so that the laryngoscope is always operational in emergency, anaesthesia and resuscitation. Maintenance: periodically check the condition of the housing and electrical contacts to ensure optimal light output. For volume orders, complete sets or tenders, contact the technical-commercial team at Cahnos. For large orders you can request a quote.

Additional information

Product type

Replacement conventional light bulb for laryngoscope

Measurements

Ø 3×14 mm

Compatibility

Small laryngoscope blades (leaves) with conventional light system

Application

Direct laryngoscopy, orotracheal intubation and resuscitation

Manufacturer reference

RIA53180

Presentacion

Unit