Description
The integrated respiratory workstation AEROS 4300S from the manufacturer DIXION (Germany) is the complete solution that your emergency department, resuscitation area or intrahospital transport unit needs to respond reliably to situations of high care demand, including the management of health emergencies and epidemic outbreaks such as COVID-19. Designed to cover from adult patients to infants, this station combines a transport ventilator with pneumatic drive and electronic control with a mobile trolley that integrates a humidifier, breathing circuit, articulated arm and oxygen cylinder holder, offering a complete, autonomous and ready-to-use ventilation station.
Technical explanation of the equipment
The AEROS 4300S performs ventilation with pneumatic drive and electronic regulation: the medical gas (air and oxygen) drives the system while control electronics precisely adjust each respiratory cycle. This architecture allows volume-controlled ventilation (A/C-V with sigh) and pressure-controlled ventilation (A/C-P), synchronised intermittent mandatory ventilation SIMV in its volume and pressure variants, spontaneous ventilation with support (SPONT/PSV), CPAP for non-invasive ventilation (NIV) and manual mode. The device incorporates backup ventilation in case of apnoea, manual breathing and alarm silence, and its trigger system combines pressure trigger and flow trigger to synchronise with the patient’s inspiratory effort. Continuous monitoring of minute volume, tidal volume, frequency, FiO2, peak pressure and PEEP, together with pressure-time and flow-time curves, allows the clinician to supervise the patient’s response at all times and adjust treatment in a personalised way.
Technical specifications
General data and ventilation modes
| Parameter / Characteristic | Value / Specification |
|---|---|
| Patient type | Adult and child (>3.5 kg) |
| Ventilation modes | A/C-V with sigh, A/C-P, SIMV-V, SIMV-P, SPONT/PSV, CPAP, MANUAL |
| Support functions | Backup ventilation in case of apnoea, manual breathing, alarm silence |
| Control system | Pneumatic drive, electronic control |
Ventilation parameter ranges
| Parameter | Range / Specification |
|---|---|
| Tidal volume (Vt) | 0-2000 ml |
| Inspiratory pressure (Pinsp) | 5-50 cmH2O |
| Pressure support (Psupp) | 0-50 cmH2O |
| CPAP (NIV) | 0-30 cmH2O |
| PEEP | 0-30 cmH2O |
| Pressure trigger | -20 to 0 cmH2O |
| Flow trigger | 2-30 L/min |
| Respiratory rate (f) | 1-120 lpm (A/C); 1-40 lpm (SIMV) |
| I:E ratio | 4:1 to 1:10 |
| Pause time (Tpause) | 0-5 seconds |
| O2 concentration | 40-100% |
| Maximum inspiratory flow | 90 L/min |
Monitoring and alarms
| Parameter | Specification |
|---|---|
| Monitoring | VM, Vt, frequency (f), FiO2, Ppeak, PEEP |
| Curves | Pressure-time (P-T), flow-time (F-T) |
| High VM alarm | OFF, 1-25 L |
| Low VM alarm | OFF, 0-24 L |
| High FiO2 alarm | OFF, 50-100% |
| Low FiO2 alarm | OFF, 35-99% |
| High airway pressure alarm (Paw) | 6-80 cmH2O |
| Low airway pressure alarm (Paw) | 0-40 cmH2O |
| System alarms | Mains failure, gas failure, O2 deficiency, high VM, low battery, no Vt, apnoea, high pressure |
Integrated station configuration
| Component | Description |
|---|---|
| Mobile trolley | Wheeled structure for intrahospital transport |
| Oxygen cylinder holder | Integrated bottle holder |
| Humidifier | Patient circuit humidification unit |
| Breathing circuit | Complete patient circuit |
| Articulated arm | Adjustable support for the circuit and accessories |
| Accessories tray | Integrated storage tray |
Equivalences and cross-references
The AEROS 4300S belongs to the DIXION ventilation range (Vertrieb medizinischer Geräte GmbH, Düsseldorf, Germany), distributed by Cahnos. Its base reference for emergency and transport ventilator is the AEROS 4300 (SKU AEROS4300), on which the integrated station is configured. As higher references of the same family, the AEROS 4600 (SKU AEROS4600), a dual invasive and non-invasive ventilator for intensive care and emergency, and the AEROS 4800 (SKU AEROS4800), an ICU ventilator for adult and paediatric patients with apnoea ventilation, stand out. In the market, functionally comparable equipment from other manufacturers of emergency and transport ventilation with pneumatic drive and non-invasive ventilation support is used, with which it shares a philosophy of mobility, robustness and ease of use. Our technical-commercial team can confirm equivalences, accessory compatibilities and conditions for equipment supply and ventilator fleet renewal projects.
Selection tips and variants of interest
To choose the most suitable configuration, consider the intended use: if you need a complete ventilation station for emergency, resuscitation or intrahospital transport with its own mobility, the AEROS 4300S station with trolley, humidifier, breathing circuit and O2 cylinder holder is the most complete option. If you already have your own supports or trolleys, the AEROS 4300 base ventilator may be considered. For intensive care units requiring advanced invasive and non-invasive ventilation, please refer to the AEROS 4600 and AEROS 4800 models. Always verify the availability of medical gas (air and oxygen outlets) and the electromagnetic compatibility regulations applicable in your facility. Our technical-commercial department will advise you on the selection, commissioning and maintenance of the equipment.