Description
1. Product Presentation
At Cahnos we offer you the absorbable multifilament suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality, a professional reference designed for the supply of operating theatres, central purchasing departments and ophthalmic surgery clinics. This presentation incorporates a straight triangular point needle with conventional cutting of 60 mm (GS60), an undyed USP 3/0 75 cm thread and a non-grooved surface that slides smoothly through tissue. Predictable performance, excellent initial tensile strength, minimal tissue reaction and reliable knot security, supplied in a box of 12 units.
2. Technical explanation of the material and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, structured as a multifilament braid that provides flexibility, soft handling and great knot security. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread degrades into substances that the body metabolises without generating relevant tissue reaction. The RAPID variant is optimised for short-term support: it retains 50 % of its tensile strength at 5 days and loses 100 % of its strength at 14 days, with complete absorption between 40 and 45 days.
The straight GS60 needle, 60 mm, with a triangular point and conventional cutting and a non-grooved surface, facilitates penetration into firm and low-elasticity tissues with absolute control of the path, being particularly suitable for manual suturing on direct-access surfaces, approximation stitches, superficial continuous sutures, ligatures and ophthalmic surgery procedures. The undyed colour provides aesthetic discretion without interfering with visualisation of the surgical field.
3. Technical Specifications
| Parameter | Specification |
| SKU Cahnos | AMP2L22GS6030 |
| Tariff reference (PREMISUT) | P2L22GS6030 |
| Material | Polyglactin 910 (PGLAR), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament, non-grooved surface |
| Gauge | USP 3/0 (metric 2) |
| Thread length | 75 cm (single strand) |
| Needle shape | Straight |
| Tip type | Triangular — conventional cutting |
| Needle size | GS60 (60 mm) |
| Colour | Colourless |
| Absorption | By hydrolysis, between 40 and 45 days |
| Sterilisation | Gamma radiation; sterile, single-use |
| Quality | Prime (PREMISUT) |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
Tensile strength retention profile after implantation:
| Time point | Tensile strength retention |
| 5 days | 50% of initial strength |
| 14 days | 0% (total loss of strength) |
| Complete absorption | 40 – 45 days by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot security, with a fully predictable absorption rate.
4. Equivalences and Cross-References
In terms of category, rapid-absorption polyglactin 910 corresponds to the rapid-absorption synthetic absorbable braided sutures on the market. The closest equivalent family is VICRYL RAPIDE™ from Ethicon/Johnson & Johnson MedTech (low molecular weight polyglactin 910, same composition 90 % glycolide / 10 % L-lactide, same absorption profile of 40–45 days and total loss of strength at 14 days), as well as the Safil Quick range from B. Braun in the rapid-loss-of-strength multifilament absorbables segment.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL RAPIDE™ | W9943 | Comparable by category (not interchangeable 1:1) | Same material (polyglactin 910), USP 3/0, undyed, 75 cm and straight needle of 60 mm; the difference lies in the point type: reverse cutting compared to the conventional cutting of this reference. |
There is no manufacturer-validated equivalence chart that cross-references this specific configuration (straight needle, conventional cutting, GS60, 60 mm, USP 3/0 gauge, undyed thread, 75 cm) with references from other commercial brands; consult the technical department of Cahnos before using this information in tenders or direct substitution of references. Any VICRYL RAPIDE™ code or other rapid-absorption polyglactin 910 brands must be checked against their technical data sheet and IFU before proposing substitution, as needle nomenclatures and strand lengths vary by manufacturer. The brands mentioned belong to their respective manufacturers and are cited solely as equivalence references.
5. Selection tips and variants of interest
The USP 3/0 gauge is very versatile and is indicated for skin, subcutaneous tissue, mucosa and tissues with moderate tension, as well as for tissue approximation, ligatures and ophthalmic surgery. The straight GS60 needle with triangular point and conventional cutting is ideal for approximation and ligature sutures with direct access to the surgical field; for tissues with limited access or reduced fields, consider versions with a curved needle (3/8 or 1/2).
Variants of interest within the Cahnos catalogue:
- AMP2L22GS6030.2 (price list P2L22RGS6030.2): same GS60 needle, USP 3/0, undyed, double thread 2×75 cm.
- AM2L22GS6030: same GS60 configuration, USP 3/0, undyed, 75 cm, in standard quality.
- AMP2L22GS4830 (price list P2L22GS4830): straight GS48 needle, USP 3/0, undyed, 75 cm, for smaller fields.
- AMP222GS6030: rapid-absorption polyglycolic acid (PGAR), straight GS60 needle, USP 3/0, undyed, 75 cm, as a material alternative.
For protocols requiring a longer support, compare with medium-duration polyglactin 910 (PGLA, absorption 56–72 days) or with polyglycolic acid (PGA, absorption 60–90 days) available in a straight needle format. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions regarding volume, hospital supply agreements or enquiries about equivalences from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews