Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID range) is the surgical reference when the procedure requires short-term wound support, predictable reabsorption and excellent tissue handling. Its straight 48 mm needle with triangular conventional cutting point (GS48) offers firm penetration and absolute control of the path, being especially valued in manual suturing of direct access, approximation of soft tissues, ligatures and ophthalmic surgery.
Presented in a box of 12 units, it is a reliable and sterile solution for operating theatres, purchasing centres, day hospitals and ophthalmic clinics, with special conditions for hospital supply contracts and an excellent price-quality ratio for the professional B2B channel.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a non-grooved finish. This configuration provides flexibility, low shape memory, smooth passage through tissue and firm, secure knot tying.
In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days, retaining approximately 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This makes it suitable for superficial tissues and temporary approximation of soft tissues where material removal is not required.
The straight GS48 needle (48 mm), with triangular conventional cutting point and non-grooved surface, penetrates firm tissues with total control of the path, suitable for manual suturing on direct access surfaces. The colourless thread provides maximum discretion on the surgical field. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P2L22GS4820
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided multifilament, non-grooved surface |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 2/0 (metric 3) |
| Colour | Colourless |
| Thread length | 75 cm (single strand) |
| Needle shape | Straight |
| Needle tip | Triangular — conventional cutting (conventional cutting) |
| Needle size | GS48 (48 mm) |
| Absorption mechanism | Hydrolysis, 40-45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Factory reference | P2L22GS4820 |
| SKU Cahnos | AMP2L22GS4820 |
| Commercial format | Box of 12 units |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40-45 days, by hydrolysis (predictable and uniform rate) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.339 mm (indicative, according to USP Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widespread categories of multifilament absorbable sutures in the surgical market. At category level, this reference corresponds to braided synthetic absorbable sutures with rapid loss of strength: the closest homologous family is VICRYL RAPIDE™ (Ethicon / Johnson \u0026 Johnson MedTech), with the same 90% glycolide / 10% L-lactide composition and the same 40-45 day absorption profile with total loss of strength at 14 days, as well as the Safil Quick and Novosyn Quick ranges (B. Braun) in the rapid-absorption multifilament absorbable segment.
There is no manufacturer-validated equivalence table that cross-references this specific configuration (straight conventional cutting GS48 needle of 48 mm, USP 2/0 gauge, colourless non-grooved 75 cm thread) with references from other commercial houses; consult the technical department before use in tenders. Any VICRYL RAPIDE™ code or other rapid-absorption polyglactin 910 brand must be checked against its technical data sheet and IFU before proposing substitution, since needle nomenclatures, point type (conventional cutting vs reverse cutting) and configuration (single strand vs double strand) vary by manufacturer. The cited brands belong to their respective manufacturers and are mentioned only as a category equivalence reference, not interchangeable 1:1.
5. Selection tips and variants of interest
To choose the correct suture, verify three parameters: USP gauge (this model, USP 2/0, is intended for soft tissues of thin-medium thickness and approximations requiring short-term support), needle geometry (straight conventional cutting GS48 for direct access sutures with path control; circular 3/8 or 1/2 variants are reserved for reduced fields) and configuration (single 75 cm strand or double strand for greater yield per unit).
Variants of interest within the Cahnos catalogue in the same PGLAR RAPID straight-cut family: the double-strand version AMP2L22GS4820.2 (GS48, USP 2/0, colourless, 2×75 cm) to optimise performance in the operating theatre; AMP2L22GS4830 (GS48, USP 3/0, colourless, 75 cm) for a finer gauge; AMP2L22GS6030 (GS60, USP 3/0, colourless, 75 cm, Prime) and AM2L22GS6030 (GS60, USP 3/0, standard quality) for a longer straight needle; and AMP222GS4820 (PGAR RAPID, GS48, USP 2/0, colourless, 75 cm) as a material alternative with the same rapid absorption profile. If the protocol requires longer support, compare with medium-duration polyglactin 910 (PGLA, absorption 56-72 days), such as reference P1L28GS4830.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or queries about equivalences from other commercial houses, contact the technical-commercial team at Cahnos.