We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle 3/8 Circle Triangular Point Precision Reverse Cutting XDS13 Square Body 13 mm · USP 4/0 · Colourless · 45 cm (Ref. P2L21XDS1340) · Box of 12 units

Original price was: 93,16 €.Current price is: 58,70 €.

Absorbable multifilament suture PREMISUT RAPID of Poliglactin 910 (PGLAR PRIME), with rapid absorption by hydrolysis in 40–45 days and tensile strength retention of 50 % at 5 days and 0 % at 14 days. It incorporates a ⅜ circle needle with triangular point in extra-long precision reverse cutting and 13 mm square body (XDS13 Prime profile), which guarantees a clean and controlled passage without rotation in the needle holder. USP 4/0 gauge, 45 cm undyed non-grooved suture, sterile by gamma radiation and single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery. Presentation in a box of 12 units. Ref. P2L21XDS1340.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L21XDS1340

Description

1. Commercial Introduction

The Absorbable Multifilament Suture PGLAR Poliglactin 910 RAPID in Prime quality (PREMISUT RAPID) is the reference choice for B2B supply to operating theatres, ophthalmology clinics, plastic and cosmetic surgery services, dermatology and purchasing centres that require a synthetic absorbable suture with rapid absorption, exceptional handling and maximum knot security. Its ⅜ circle needle with triangular reverse cutting precision point (extra-long cutting edge) and 13 mm square body (XDS13 Prime profile) offers controlled penetration and a clean track, highly valued in skin, mucosa and tissues under tension. The 45 cm undyed suture provides maximum discretion on the surgical field, with a practical presentation for ambulatory surgery and minor surgical procedures.

2. Technical Explanation

Poliglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a non-grooved finish. In the RAPID variant, the suture is formulated to lose tensile strength at an accelerated rate: it retains 50 % of the initial strength at 5 days and 0 % at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it particularly suitable for superficial tissues with rapid healing, ligatures and ophthalmic surgery, where prolonged tensile support is not required.

The XDS needle (precision reverse cutting with extra-long cutting edge) concentrates the cutting edge at the point, creates a clean entry hole by directing the cut away from the wound, preserves the skin edge and prevents the cut from widening in the puncture bed. The square body optimises grip in the needle holder, preventing rotation and improving the precision of the surgical gesture. Hydrolysis absorption is uniform and predictable, with minimal tissue reaction and excellent knot-tying capability. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide
Structure Braided multifilament, non-ribbed
Thread colour Colourless
USP size 4/0 (metric 1.5; diameter 0.15 – 0.199 mm)
Thread length 45 cm
Needle shape 3/8 circle
Needle tip Triangular, precision reverse cutting (extra-long cutting edge)
Needle body Square
Needle size XDS 13 mm (Prime)
Quality Prime (PREMISUT RAPID)
Absorption By hydrolysis, 40 – 45 days
Sterilisation Gamma radiation, single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery
Presentation Box of 12 units
Factory reference P2L21XDS1340 · SKU Cahnos AMP2L21XDS1340

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Size equivalence

USP size Metric size Approximate diameter
4/0 1.5 0.15 – 0.199 mm (indicative according to Pharmacopoeia)

3.4. Needle variants within the PGLAR RAPID range

Needle profile Point / body Recommended use
XDS 13 mm (this product) Precision reverse cutting, extra-long cutting edge, square body Ophthalmology, dermo-aesthetics, plastic-cosmetic: clean passage without rotation
XDS 19 mm Precision reverse cutting, extra-long cutting edge, square body Firm or thicker tissues with the same point precision
DS 19 mm Classic reverse cutting, triangular body and point Standard reverse cutting alternative for fine tissues

4. Equivalences and Cross-References

Poliglactin 910 is the most widely used clinical reference multifilament absorbable in the surgical market, and the RAPID variant (low molecular weight) has its commercial counterpart in the main companies in the sector. This reference shares material, USP 4/0 gauge, 3/8 circle curvature, reverse cutting needle and undyed suture with the rapid absorption lines of poliglactin 910 and low molecular weight polyglycolic acid.

In the market, the following homologous families are identified, whose technical data sheets must be consulted before any substitution: VICRYL RAPIDE™ from Ethicon / Johnson & Johnson MedTech (low molecular weight poliglactin 910, braided and undyed), Safil Quick™ from B. Braun (rapid polyglycolic acid, braided and coated), DemeCRYL™ Fast from DemeTECH and Surgicryl Fast Absorb from SMI. The comparison with these lines is declared at category level, not interchangeable 1:1: the geometry and body of the needle (XDS square body profile versus standard profiles), the suture coating, the length and the tensile strength retention values published by each manufacturer differ.

There is no manufacturer-validated equivalence table for this reference; consult the technical department before use in tendering.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is indicated for fine and delicate tissues: skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The XDS13 Prime needle (precision reverse cutting with square body and extra-long cutting edge) is especially recommended in plastic and cosmetic surgery, dermatology and ophthalmology, where the needle passage must be clean, without rotation and without tearing.

Within the same PGLAR RAPID range, the same XDS13 needle is available in USP 5/0 gauge with 45 cm suture (ref. P2L21XDS1350, SKU AMP2L21XDS1350). If you require a longer needle, consider the XDS19 Fine Prime variant of 45 cm (SKU AMP2L21XDS1940FN) or the XDS19 Prime version of 75 cm (SKU AMP2L22XDS1940). If you prefer a conventional reverse cutting point (triangular body and point), consult the DS19 variant of the same range (SKU AMP2L21DS1940FN); if your protocol requires the same XDS13 needle in rapid polyglycolic acid material, the PGAR line is available (SKU AMP221XDS1340). For longer tensile support (56–72 days), consider the standard poliglactin 910 PGLA range (SKU P1L21XDS1340).

The undyed version offers maximum aesthetic discretion; if you require greater visibility in the field, request the same configuration in violet colour on demand. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions or volume orders, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide)

Structure

Non-grooved braided multifilament

USP size

4/0 (metric 1.5; diameter 0.15-0.199 mm)

Needle tip

Triangular, precision reverse cutting (extra-long cutting edge)

Needle body

Square

Needle size

XDS 13 mm (Prime)

Quality

Prime (PREMISUT RAPID)

Sterilisation

Gamma radiation, single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P2L21XDS1340

Indications

Tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery

Medida de aguja

XDS 13

Usp

4/0

Color

Colourless

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle 3/8 Circle Triangular Point Precision Reverse Cutting XDS13 Square Body 13 mm · USP 4/0 · Colourless · 45 cm (Ref. P2L21XDS1340) · Box of 12 units”

Your email address will not be published. Required fields are marked *