We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle ⅜ Circle Triangular Point Reverse Cutting Precision XDS 24 mm Square Body · USP 3/0 · Colourless · 70 cm (Ref. P2L28XDS2430) · Box 12 units

Original price was: 93,16 €.Current price is: 58,70 €.

Multifilament absorbable suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality, with rapid absorption by hydrolysis in 40–45 days and tensile strength retention of 50% at 5 days and 0% at 14 days. It incorporates a ⅜ circle needle with triangular point in precision reverse cutting (Reverse Extra Cutting) with extra-long cutting edge and square body of 24 mm (XDS24 Prime profile), ensuring a clean and controlled passage without rotation in the needle holder. USP 3/0 gauge, 70 cm undyed non-grooved suture. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic procedures. Presentation in box of 12 units. Ref. P2L28XDS2430.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L28XDS2430

Description

1. Commercial Introduction

The PGLAR Poliglactina 910 RAPID Multifilament Absorbable Suture in Prime quality (PREMISUT RAPID) is the reference choice for B2B supply to operating theatres, ophthalmology clinics, plastic and cosmetic surgery services and purchasing centres that require a synthetic absorbable suture with rapid absorption, exceptional handling and maximum knot security. Its ⅜ circle needle with precision reverse cutting triangular point (extra-long cutting edge) and square body of 24 mm (XDS24 Prime profile) offers controlled penetration and a clean track, highly valued in skin, mucosa and tissues under tension. The 70 cm undyed suture provides maximum discretion on the surgical field.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure. In the RAPID variant, the suture is formulated to lose tensile strength rapidly: it retains 50% of initial strength at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it particularly suitable for superficial tissues with rapid healing, ligatures and ophthalmic surgery, where prolonged tensile support is not required.

The XDS (Reverse Extra Cutting) needle concentrates the cutting edge at the tip, creates a clean entry hole by directing the cut away from the wound, preserves the skin edge and prevents the cut from widening in the puncture bed. The square body optimises grip in the needle holder, preventing rotation and improving the precision of the surgical gesture. Hydrolytic absorption is uniform and predictable, with minimal tissue reaction and excellent knot-tying capability. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Characteristic Detail
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide
Structure Braided multifilament, non-ribbed
Thread colour Colourless (violet on request)
USP size 3/0 (metric 3, diameter 0.20 – 0.249 mm)
Thread length 70 cm
Needle shape ⅜ circle
Needle tip Triangular, precision reverse cutting (Reverse Extra Cutting), extra-long cutting edge
Needle body Square
Needle size XDS 24 mm (Prime)
Quality Prime (PREMISUT RAPID)
Absorption By hydrolysis, 40 – 45 days
Sterilisation Gamma radiation, single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery
Presentation Box of 12 units
Factory reference P2L28XDS2430 · SKU Cahnos AMP2L28XDS2430

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable
Tissue reaction Minimal

3.3. Size equivalence

USP size Approximate diameter Metric size
3/0 0.20 – 0.249 mm 3

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used clinical reference multifilament absorbable in the surgical market. This reference shares material, USP 3/0 gauge, ⅜ circle curvature, reverse cutting needle and 70 cm of undyed suture with the main polyglactin 910 lines on the market. Only codes verified in public catalogue and authorised distribution sources are listed; the comparison is declared at category level, not 1:1 interchangeable, because the needle, body and/or absorption profile differ.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE™ (braided polyglactin 910, colourless) NW2732 – USP 3/0, ⅜ circle, reverse cutting, colourless Comparable by category (not interchangeable 1:1) Same material, gauge and rapid absorption profile (50% at 5 days, 0% at 10-12 days according to data sheet); the needle differs (PS reverse cutting with round body versus XDS24 Prime with extra-long cutting edge and square body).
Ethicon (Johnson & Johnson MedTech) Coated VICRYL® (braided polyglactin 910, colourless) J427H – USP 3/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 70 cm Comparable by category (not interchangeable 1:1) Same material, gauge and length; the absorption profile differs (standard VICRYL longer versus RAPID), the needle (PS-2 19 mm versus XDS24) and the coating.
DemeTECH DemeCRYL™ (polyglactin 910) G1173024F4P – USP 3/0, 24 mm needle, ⅜ circle, reverse cutting, colourless, 70 cm, box of 12 Comparable by category (not interchangeable 1:1) The closest in geometry: same needle size (24 mm, ⅜ reverse cutting), gauge and length; the absorption profile differs (standard DemeCRYL 56-70 days versus RAPID 40-45 days) and the needle body.

In the same therapeutic block are the rapid absorption lines from B. Braun (Safil Quick / Novosyn Quick), comparable by category by material and absorption profile, although with their own codifications depending on needle configuration; their specific codes must be verified against the manufacturer’s catalogue before any substitution. There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders.

5. Selection tips and variants of interest

USP 3/0 gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue closures. The XDS24 Prime needle (precision reverse cutting with square body) is especially recommended in plastic and cosmetic surgery, dermatology and ophthalmology, where the needle passage must be clean and without tearing.

  • If greater tensile support is required, consider the PGLA – Polyglactin 910 range with standard absorption (56-72 days) or the PDO/PDS monofilament (180-210 days).
  • Same XDS24 Prime needle available in gauge 2/0 (ref. P2L28XDS2420) and in 45 cm length (ref. P2L21XDS2430), as well as in other absorbable families (PGCL, PGA, PDO) to unify supplier.
  • If you prefer a conventional precision cutting point, see the XNS variant of the same PGLAR RAPID range; if you prefer a cylindrical body, the HR/HRP/HRT ranges.
  • The undyed version offers maximum aesthetic discretion; if greater visibility in the field is required, request the same configuration in violet on demand.
  • Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions or volume orders, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament, non-ribbed

USP size

3/0 (metric 3, diameter 0.20-0.249 mm)

Needle tip

Triangular, precision reverse cutting (Reverse Extra Cutting), extra-long cutting edge

Needle body

Square

Needle size

XDS 24 mm (Prime)

Quality

Prime (PREMISUT RAPID)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation, single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P2L28XDS2430

Medida de aguja

XDS 24

Usp

3/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle ⅜ Circle Triangular Point Reverse Cutting Precision XDS 24 mm Square Body · USP 3/0 · Colourless · 70 cm (Ref. P2L28XDS2430) · Box 12 units”

Your email address will not be published. Required fields are marked *