We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Multifilament Absorbable Suture PGLAR Poliglactina 910 RAPID Prime · 3/8 Circle Triangular Reverse Cutting Needle DS12 (12 mm) · USP 6/0 (Metric 0.7) · Colourless Thread 75 cm · Box of 12 units · Ref. P2L22DS1260

Original price was: 83,01 €.Current price is: 60,15 €.

Multifilament absorbable suture of poliglactina 910 (PGLAR) in RAPID variant and Prime quality, with a ⅜ circle needle with a triangular point with reverse cutting edge of 12 mm (DS12 profile), USP 6/0 gauge and colourless braided thread of 75 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses it completely at 14 days. Sterilised by gamma radiation, single-use and with minimal tissue reaction; indicated for tissue approximation, ligatures and ophthalmic surgery. Factory ref. P2L22DS1260 · Presentation in box of 12 units · Minimum order 10 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS1260

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality is the reference choice for the professional who needs a synthetic absorbable thread with predictable behaviour, excellent handling and rapid loss of resistance, designed for fast-healing tissues. Its configuration with a ⅜ circle needle, reverse cutting triangular body and point of 12 mm (DS12), USP 6/0 gauge and 75 cm colourless thread makes it an excellent solution for approximation of very fine tissues, ligatures and ophthalmic surgery.

Presented in a box of 12 sterile units, it guarantees batch traceability and reduces handling in the operating theatre, optimising surgical times. An excellent value for money for hospitals, clinics, ambulatory surgery and B2B supply contracts.

2. Technical explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a coated braided multifilament structure that provides flexibility, low shape memory, smooth passage through tissue and firm, secure knot tying.

In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days, so in most indications it does not require removal of the material (wound support for 7 to 10 days).

The ⅜ circle needle (135°) with reverse cutting triangular body and point (reverse cutting) directs the cutting edge away from the wound: it creates a clean entry hole that preserves the skin edge and prevents the cut from widening in the puncture bed, ideal for thin skin, mucous membranes, conjunctiva and firm tissues of little thickness. Prime quality ensures consistency of sharpness and finish batch to batch. The colourless thread offers maximum discretion on the surgical field. Single-use product, sterile by gamma radiation and not re-sterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference P2L22DS1260

Parameter Specification
Thread material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant low molecular weight
Thread structure Coated braided multifilament, colourless
Quality / range Prime (PREMISUT RAPID range)
Gauge USP 6/0 (metric 0.7; approximate diameter 0.070 – 0.099 mm)
Thread length 75 cm (mounted 1 needle / 1 thread)
Needle shape 3/8 circle (135°)
Needle body and point Triangular, reverse cutting
Needle size DS12 (12 mm), Prime quality
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of fine tissues, ligatures, skin and mucosa closure, ophthalmic surgery
Presentation Box of 12 units · Minimum order 10 boxes
Factory reference P2L22DS1260
SKU Cahnos AMP2L22DS1260

3.2. Tensile strength retention and absorption profile

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)
Wound support 7 – 10 days

3.3. Gauge equivalence (USP Pharmacopoeia)

USP size Metric size Approximate diameter
6/0 (this product) 0.7 0.070 – 0.099 mm
5/0 1 0.10 – 0.149 mm
4/0 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm

4. Equivalences and Cross-References

Rapid-absorbing polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market, whose international clinical reference is the VICRYL RAPIDE line (Ethicon / Johnson \u0026 Johnson MedTech), with which it shares composition (90% glycolide / 10% L-lactide), absorption mechanism by hydrolysis and accelerated resistance loss profile (≈50% at 5 days, 0% at 14 days). Only codes whose attributes have been verified in the manufacturer’s official catalogue and authorised distribution are included; none should be considered 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, coated braided, undyed) VR489 – USP 6/0, P-1 Prime needle of 11 mm in 3/8 circle, reverse cutting point, colourless thread of 75 cm (single dose; usual box of 12 or 36 units) Comparable by category (not interchangeable 1:1) They match in material, rapid absorption profile (≈50% at 5 days), USP 6/0 gauge, 3/8 circle curvature, reverse cutting point family, needle size 11–12 mm (within tolerance ±1 mm) and thread length of 75 cm; they differ in the needle profile nomenclature (P-1 Prime vs DS12) and the braid coating. Code confirmed in authorised Ethicon distribution.
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, coated braided, undyed) W9913 – USP 6/0, P-1 Prime needle of 11 mm in 3/8 circle, reverse cutting point, colourless thread of 45 cm, box of 12 units Comparable by category (not interchangeable 1:1) Same material, USP 6/0 gauge, 3/8 curvature, reverse cutting point and 11 mm needle (within tolerance ±1 mm); it differs in thread length (45 cm vs 75 cm) and profile nomenclature (P-1 Prime vs DS12). Code confirmed in official Ethicon EMEA catalogue and authorised distribution.

Also included as homologous ranges in the rapid absorption segment are Safil Quick and Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category by material and absorption profile; for the exact combination USP 6/0 / DS12 reverse cutting needle / 75 cm thread, their specific codes must be confirmed with each manufacturer. There is no manufacturer-validated equivalence table that cross-references this specific reference with codes from other brands; consult the technical department before use in tenders, verifying in each official data sheet the USP 6/0 gauge (metric 0.7), the 3/8 circle curvature, the needle type and size (12 mm reverse cutting triangular), the thread length (75 cm) and the colourless colour.

5. Selection tips and variants of interest

The USP 6/0 gauge (metric 0.7) is indicated for very fine and delicate tissues: thin skin, mucosa, conjunctiva or eyelids, where a small-diameter thread with good initial resistance is required. The 12 mm 3/8 circle reverse cutting needle is especially recommended when a firm and clean passage is needed in reduced accesses or firm tissues, typical in microsurgery, dermatology, minor surgery and ophthalmology.

Within the same PGLAR Poliglactina 910 RAPID Prime family with DS12 needle, Cahnos offers complementary gauges: USP 4/0 (ref. P2L22DS1240 · SKU AMP2L22DS1240) and USP 5/0 (ref. P2L22DS1250 · SKU AMP2L22DS1250). For a longer needle with other gauges, the DS16 (USP 5/0, SKU AMP2L22DS1650), DS19 (USP 3/0, SKU AMP2L22DS1930) and DS30 (USP 2/0, SKU AMP2L22DS3020) variants are available. If the protocol prefers a precision reverse cutting point with a square body, consider the XDS range from the same RAPID family (e.g. USP 6/0 XDS11 with 45 cm thread, SKU AMP2L21XDS1160). If your protocol requires longer tensile support (56–72 days), consider the PGLA range of standard-absorption poliglactina 910. The colourless version offers maximum aesthetic discretion; if greater visibility is required, request the same configuration in dyed thread on demand.

As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR) – copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant

Thread structure

Coated braided multifilament

Quality

Prime (PREMISUT RAPID range)

Gauge

USP 6/0 (metric 0.7; approx. diameter 0.070-0.099 mm)

Thread length

75 cm (mounted 1 needle / 1 thread)

Needle shape

3/8 circle (135°)

Needle type

Triangular body and point, reverse cutting

Needle size

DS12 (12 mm), Prime quality

Tensile strength

50% at 5 days; 0% at 14 days

Wound support

7-10 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Tissue reaction

Minimal

Presentation

Box of 12 units; minimum order 10 boxes

Manufacturer reference

P2L22DS1260

Indications

Approximation of fine tissues, ligatures, skin and mucosa closure, ophthalmic surgery

Medida de aguja

DS 12

Usp

6/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Multifilament Absorbable Suture PGLAR Poliglactina 910 RAPID Prime · 3/8 Circle Triangular Reverse Cutting Needle DS12 (12 mm) · USP 6/0 (Metric 0.7) · Colourless Thread 75 cm · Box of 12 units · Ref. P2L22DS1260”

Your email address will not be published. Required fields are marked *