We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · 3/8 Circle Needle Triangular Point Reverse Cutting DS 19 mm · USP 4/0 (Metric 1.5) · Undyed · 45 cm · Box of 12 units (Ref. P2L21DS1940FN)

Original price was: 62,22 €.Current price is: 38,40 €.

Absorbable multifilament suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality, with a ⅜ circle needle with triangular point in reverse cutting of 19 mm (DS 19 profile), USP 4/0 gauge (metric 1.5) and undyed grooved suture of 45 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength at 5 days and loses it completely at 14 days. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for approximation of fine tissues, ligatures and ophthalmic surgery. Ref. P2L21DS1940FN · Price per box of 12 units · Minimum B2B order.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L21DS1940FN

Description

1. Commercial Introduction

The PGLAR Polyglactin 910 RAPID absorbable multifilament suture in Prime quality (range PREMISUT RAPID) is the accelerated absorption surgical closure solution for hospitals, general and ambulatory surgery operating theatres, emergency departments, ophthalmology clinics, plastic-cosmetic surgery clinics and B2B purchasing centres that need a braided, flexible thread with early and fully predictable strength loss.

Its ⅜ circle needle with triangular reverse cutting point of 19 mm (DS 19 profile) ensures clean and controlled penetration in fine and firm tissues, while the 45 cm undyed thread offers maximum discretion on the surgical field. A practical and cost-effective presentation, in a box of 12 units, designed for fast-healing tissues and for microsurgery and ophthalmology techniques.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a coating and grooved finish that favours thread sliding, smooth handling and a firm, secure knot.

In the RAPID variant (low molecular weight polyglactin 910), the thread is formulated to lose tensile strength in an accelerated and programmed manner: it retains 50% of the initial strength at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery.

The reverse cutting needle orients the cutting edge away from the wound, generating a clean entry orifice that preserves the skin edge and prevents the cut from widening in the puncture bed. Prime quality guarantees consistency of sharpening and finish batch to batch, with minimal tissue reaction, excellent tensile strength and secure knot tying. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P2L21DS1940FN · SKU AMP2L21DS1940FN)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 4/0 (metric 1.5)
Thread diameter 0.15 – 0.199 mm (indicative, according to Pharmacopoeia)
Thread colour Colourless
Thread length 45 cm
Needle shape 3/8 circle (⅜ circular)
Needle tip Triangular, reverse cutting (reverse cutting), triangular body and point
Needle size DS 19 mm (Prime)
Swaged 1 needle / 1 suture per unit
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units
Factory reference P2L21DS1940FN · SKU Cahnos AMP2L21DS1940FN

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Gauge equivalence (USP Pharmacopoeia)

USP size Metric size Approximate diameter
4/0 (this product) 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm
2/0 3 0.30 – 0.339 mm

3.4. Reference code decoding

The official reference P2L21DS1940FN breaks down as follows: P (Prime range) + 2L21 (45 cm thread in the PGLAR family) + DS19 (⅜ circle needle with classic reverse cutting triangular point of 19 mm, triangular body and point) + 40 (USP 4/0 gauge) + FN (fine profile, Fine). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or bidding.

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech), with which it shares composition, hydrolysis absorption mechanism and accelerated strength loss profile. The reference P2L21DS1940FN shares with homologous lines the material, USP 4/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle, 45 cm undyed thread and 1 needle configuration. Below are included only codes whose attributes have been verified in the manufacturer’s official catalogue and authorised distributors; none of these references should be considered interchangeable 1:1 without validation by the technical department.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) VR496 – USP 4/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 45 cm Comparable by category (not interchangeable 1:1) Same material, USP 4/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle, undyed thread and 45 cm length; the needle profile nomenclature (classic DS vs. PS-2) and the thread coating differ. Code confirmed in Ethicon’s official catalogue and authorised distributors.
Ethicon (J&J MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9922 – USP 4/0, ⅜ circle reverse cutting needle 19 mm, undyed thread 75 cm Comparable by category (not interchangeable 1:1) Same needle and gauge configuration (4/0, 19 mm, ⅜ circle, reverse cutting) but 75 cm thread instead of 45 cm; box of 12 units. Code verified in authorised distributors.
B. Braun / Aesculap Safil Quick (low molecular weight polyglycolic acid, braided and coated) C0046629 – USP 4/0, ⅜ circle reverse cutting needle with micro-point (DSMP) of 19 mm, undyed thread of 45 cm Comparable by category (not interchangeable 1:1) Same USP 4/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle, undyed thread and 45 cm length; the base material (polyglycolic acid vs. polyglactin 910), needle profile (DSMP vs. DS) and presentation (12/36 units) differ. Code verified in authorised distribution.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tenders. Homologous ranges in the rapid absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category by material and absorption profile, although for the exact combination USP 4/0 / DS 19 mm needle / 45 cm, their specific codes must be confirmed with the manufacturer. Standard VICRYL (56–72 day absorption) is not comparable to this RAPID version.

5. Selection tips and variants of interest

USP 4/0 gauge (metric 1.5) is a common choice in fine skin, mucous membranes, paediatrics and fast-healing tissues where an optimal balance between strength and fineness is required: conjunctival suture in ophthalmology, approximation of mucous membranes, subcutaneous tissue and ligation of small-calibre vessels. The ⅜ circle reverse cutting needle of 19 mm is especially recommended when a firm and precise passage through the skin or mucous membranes is required without tearing the edge, typical in ophthalmology and microsurgery.

Within the same PGLAR Polyglactin 910 RAPID Prime range, Cahnos offers complementary configurations:

Reference Variant
AMP2L21DS1940FN (P2L21DS1940FN) PGLAR RAPID Prime, DS 19 classic reverse cutting needle, USP 4/0, undyed, 45 cm (this product)
AMP2L21XDS1940FN (P2L21XDS1940FN) PGLAR RAPID Prime, XDS 19 precision needle with square body and extra-long cutting edge, USP 4/0, undyed, 45 cm (for firm tissues, passage without rotation)
AMP2L22XDS1940 (P2L22XDS1940) PGLAR RAPID Prime, XDS 19 needle, USP 4/0, undyed, 75 cm (same needle with longer suture length)
AMP2L21HS1740 (P2L21HS1740) PGLAR RAPID Prime, HS 17 half-circle needle, USP 4/0, undyed, 45 cm (another needle curvature for the same gauge)
AMP221XDS1940FN (P221XDS1940FN) PGAR RAPID Prime (polyglycolic acid), XDS 19 needle, USP 4/0, undyed, 45 cm (same needle geometry in PGA material)

The undyed version offers maximum aesthetic discretion in the surgical field; if greater visibility is required, request the same configuration in dyed suture on demand. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (PREMISUT RAPID range)

Gauge

USP 4/0 (metric 1.5)

Thread diameter

0.15 – 0.199 mm

Needle tip

Triangular reverse cutting, triangular body and point

Swaged

1 needle / 1 suture per unit

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures and ophthalmic surgery

Manufacturer reference

P2L21DS1940FN

Medida de aguja

DS 19

Usp

4/0

Color

Colourless

Medida de hilo

45 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · 3/8 Circle Needle Triangular Point Reverse Cutting DS 19 mm · USP 4/0 (Metric 1.5) · Undyed · 45 cm · Box of 12 units (Ref. P2L21DS1940FN)”

Your email address will not be published. Required fields are marked *