1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID Polyglactin 910 (PGLAR) is the reference for accelerated-absorption surgical closure for general and ambulatory surgery theatres, emergency departments, ophthalmology clinics and B2B purchasing centres that require a braided, flexible thread with early and fully predictable loss of strength. Its ⅜ circle 24 mm needle with reverse cutting triangular body and point (DS24) penetrates firm, non-compliant tissues with a clean, controlled passage without tearing the skin edge, while the 75 cm colourless thread offers maximum discretion on the surgical field. Practical presentation in a box of 12 sterile units, with batch traceability and factory reference 2L22DS2420.
2. Technical explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish that favours thread sliding, very smooth handling and a firm, secure knot, even in medium gauges such as USP 2/0. In the RAPID variant (low molecular weight), absorption occurs by hydrolysis over a predictable period of 40 to 45 days, retaining 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This profile makes it particularly suitable for superficial tissues with rapid healing —skin closure, mucous membranes, subcutaneous tissue—, ligation of small-calibre vessels and conjunctival suture. The ⅜ circle needle (135°) with reverse cutting triangular body and point combines penetration resistance with a clean entry hole that preserves the wound edge. Product sterile by gamma radiation, single-use and non-resterilisable: check the integrity of the packaging and the expiry date before each procedure.
3. Technical Specifications
3.1. General characteristics (Ref. 2L22DS2420 · SKU AM2L22DS2420)
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless (undyed) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8, 135°) |
| Needle body and point | Triangular reverse cutting (reverse cutting), size DS24 (24 mm) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (minimum order 30 boxes) |
| Factory reference | 2L22DS2420 |
| SKU Cahnos | AM2L22DS2420 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate.
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market, whose international clinical benchmark is the Coated VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech). The reference analysed shares material, accelerated absorption profile (≈42 days), tensile retention (50% at 5 days / 0% at 14 days), USP 2/0 gauge, ⅜ circle curvature, reverse cutting point, colourless colour and 75 cm configuration with the following verified code:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | Coated VICRYL RAPIDE (braided polyglactin 910, colourless) | W9933 – USP 2/0, PRIME needle 26 mm in ⅜ circle, reverse cutting point, colourless thread 75 cm, box of 12 | Comparable by category (not interchangeable 1:1) | Almost total match of attributes: same material (rapid-absorption polyglactin 910), USP 2/0 gauge (metric 3), ⅜ circle curvature, reverse cutting point, colourless thread 75 cm and box of 12 units; the needle size (PRIME 26 mm vs DS24 24 mm) and the thread coating differ. Code confirmed in the Ethicon EMEA catalogue and in authorised distributors. |
Homologous ranges in the rapid-absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category in terms of material and absorption profile, although for the exact combination USP 2/0 / DS24 reverse cutting needle / 75 cm thread, their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not equivalent to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official datasheet the USP 2/0 gauge (metric 3), the ⅜ circle curvature, the needle type and size (24 mm reverse cutting triangular), the thread length (75 cm) and the colourless colour.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) with a ⅜ circle needle with 24 mm reverse cutting triangular point offers an ideal balance between initial strength and handling, indicated for skin closure, subcutaneous tissue, mucous membranes, approximation of soft tissues, ligation of small-calibre vessels and ophthalmic surgery, with early loss of strength that in many indications avoids suture removal. Within the same PGLAR Polyglactin 910 RAPID range with reverse cutting needle, Cahnos offers complementary configurations: the same DS24 needle in Prime quality (AMP2L22DS2420) and in double format 2 × 75 cm (AMP2L22DS2420.2), the DS26 needle (AM2L22DS2620), the DS30 needle (AM2L22DS3020), the DS36 needle (AM2L22DS3620) and the finer USP 3/0 gauge with DS24 needle (AM2L22DS2430). For a longer tensile support profile, consider the PGLA family of standard polyglactin 910 (absorption 56–72 days, ref. 1L22DS2420). The colourless version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand. Sterile single-use product: store in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.