Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Poliglactina 910 RAPID is the reference surgical solution when the procedure requires short-term wound support, predictable reabsorption and excellent tissue handling. Its ⅜-circle needle with triangular reverse cutting body and point (36 mm) precisely penetrates tissues of medium and firm consistency, minimising trauma and facilitating secure stitches even in reduced working fields.
Presented in a box of 12 units, it is a reliable, sterile option with batch traceability for operating theatres, day hospitals, ambulatory surgery, ophthalmic clinics and hospital supply contracts, with a very competitive price-quality ratio for the professional B2B channel.
2. Technical explanation
Poliglactina 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure. This configuration provides flexibility, low shape memory, smooth passage through tissue and firm, secure knot tying.
In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days, so it does not require removal of the material in superficial tissues with rapid healing.
The ⅜-circle needle with triangular reverse cutting body and point (DS36 profile, reverse cutting) offers a very effective cutting edge in dense or fibrous tissues, with a lower risk of tearing than conventional cutting needles. The colourless grooved thread facilitates manipulation and knotting with maximum discretion on the surgical field. Sterilisation by gamma radiation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference 2L22DS3610
| Parameter | Specification |
| Thread material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided multifilament, fluted finish, colourless |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8) |
| Needle body | Triangular |
| Needle tip | Reverse cutting |
| Needle size | 36 mm (DS36) |
| Absorption mechanism | Hydrolysis, 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Factory reference | 2L22DS3610 |
| SKU Cahnos | AM2L22DS3610 |
| Commercial format | Box of 12 units |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption poliglactina 910 (low molecular weight) is one of the most widespread multifilament absorbable categories in the surgical market. The closest homologous family is VICRYL RAPIDE™ (Ethicon / Johnson & Johnson MedTech), which shares the 90% glycolide / 10% L-lactide composition, braided structure, colourless thread and the same rapid absorption profile (loss of resistance at 14 days, absorption around 42 days). However, no specific VICRYL RAPIDE code has been verified in public sources that simultaneously combines USP 0 size, ⅜-circle needle with 36 mm reverse cutting point and 75 cm thread; therefore it is not included in the table and any substitution must be checked against the official catalogue and the manufacturer’s IFU.
Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; nor is there a verified code for the exact combination USP 0 / 36 mm needle / reverse cutting point / 75 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version due to its longer resistance retention profile.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
To choose the correct suture, verify three parameters: the USP size (this model, USP 0, is intended for tissues with moderate tension: skin, subcutaneous tissue, mucosa, approximation of soft tissues and ligation of small and medium-calibre vessels), the needle geometry (⅜ circle with reverse cutting point for denser tissues, as opposed to the conical point reserved for soft tissues) and the thread length (75 cm, suitable for medium-reach suturing manoeuvres).
Within the same PGLAR Poliglactina 910 RAPID family with reverse cutting triangular needle, Cahnos offers other configurations: DS12 needle in USP 6/0 and 4/0 sizes, DS16 in USP 5/0, 4/0 and 3/0, DS19 in USP 5/0 and DS30 in USP 2/0, all colourless and with 75 cm thread, plus Prime quality variants. If the protocol prefers a conical point (taperpoint) in the same USP 0 size, see the HR26 family; and if a trocar point (tapercut) is required, the HRT36 family.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.