Description
1. Commercial Introduction
The Prime-quality PGLAR Polyglactin 910 RAPID Multifilament Absorbable Suture is the high-performance solution for B2B supply to operating theatres, general and ambulatory surgery departments, ophthalmology, emergency services and purchasing centres that require a fast-acting absorbable braided thread with excellent handling and maximum knot security. It is presented with a ½-circle needle with cylindrical body and 22 mm Taperpoint conical point (HR 22), USP 2/0 gauge, double colourless fluted thread of 2 x 75 cm, in a box of 12 units. A sterile, single-use product designed for fast-healing tissues that require short-term support, with an optimal balance between clinical performance and cost per pack.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a fluted finish and lubricating coating that facilitates smooth passage through tissue, excellent handling and firm, secure knot tying. In the RAPID variant, the polymer has a low molecular weight and accelerates the loss of strength and mass: it retains 50% of the initial tensile strength at 5 days and loses all its strength at 14 days, with complete absorption by hydrolysis between 40 and 45 days and minimal tissue reaction.
The ½-circle (160°) needle with cylindrical body and Taperpoint conical point penetrates soft tissues by separating the fibres without tearing them, minimising tissue trauma and bleeding at the entry point. The colourless thread offers maximum discretion on the surgical field, a quality especially valued in ophthalmic surgery. The double-thread format of 2 x 75 cm optimises performance per unit in procedures requiring multiple stitches. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics (Ref. P2L22HR2220.2 · SKU AMP2L22HR2220.2)
| Parameter | Specification |
| Thread material | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Length and configuration | 2 threads of 75 cm each (2 x 75 cm) |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Conical grooved (Taperpoint) |
| Needle size | 22 mm (HR 22) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L22HR2220.2 |
| SKU Cahnos | AMP2L22HR2220.2 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Fast-absorbing (low molecular weight) polyglactin 910 is the most widespread short-acting absorbable braided suture category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line (polyglactin 910), with which this reference shares material, accelerated absorption profile (≈42 days), tension retention (50% at 5 days / 0% at 14 days), USP 2/0 gauge, colourless thread and 75 cm configuration. Only codes whose attributes have been verified against industry sources (manufacturer catalogue and authorised distributors) are included:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided poliglactin 910, undyed), PS 3/8 circle needle with reverse cutting point 26 mm, 75 cm | W9933 (EMEA) | Comparable by category (not interchangeable 1:1) | Same material, fast absorption (wound support 7-10 days), USP 2/0 gauge, 26 mm needle and 75 cm colourless thread. They differ in curvature (3/8 circle vs ½ circle), point (reverse cutting vs Taperpoint conical), needle size (26 mm vs HR 22 mm) and configuration (1 thread vs 2 threads of the PGLAR format). Code confirmed in EMEA catalogue and authorised distributors. |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided poliglactin 910, undyed), MH-1 ½ circle needle with conical point 31 mm, 75 cm | W9975 (EMEA) | Comparable by category (not interchangeable 1:1) | Same material, fast absorption (≈42 days), USP 2/0 gauge (metric 3), ½-circle curvature, conical point and 75 cm colourless thread. They differ in needle size (MH-1 of 31 mm vs HR 22 mm), the exact needle design, configuration (1 thread vs 2 threads) and packaging format. Code confirmed in EMEA catalogue and authorised distributors. |
As homologous reference ranges in the sector, the fast-absorbing braided polyglactin 910 sutures from B. Braun (lines such as Safil Quick / Novosyn Quick), DemeTECH (DemeCRYL Fast) and SMI (Surgicryl Fast Absorb) are listed, whose specific codes for the exact combination USP 2/0 / Taperpoint conical needle HR 22 mm / double thread 2 x 75 cm / colourless must be confirmed with each manufacturer. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version in terms of tensile strength retention.
There is no equivalence table validated by the manufacturer that cross-references this product with other brands; consult the technical department before using in tenders, verifying on each official datasheet the USP 2/0 gauge (metric 3), the ½-circle curvature, the needle type and size (22 mm Taperpoint conical), the thread length (2 x 75 cm) and the colourless colour.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the gauge according to the anatomical area. USP 2/0 gauge with a 22 mm Taperpoint conical needle is a common choice for approximation of skin and mucous membranes, subcutaneous tissue, ligation of small and medium-calibre vessels and ophthalmic surgery, with early strength loss that in many indications avoids the need for suture removal. The double-thread format (2 x 75 cm) provides two sterile strands per pack, optimising performance per box.
Within the same PGLAR Polyglactin 910 RAPID range with cylindrical conical-point needle, Cahnos offers complementary configurations in Prime quality: AMP2L22HR2220 (same USP 2/0 reference, HR 22 mm needle, individual format of 1 x 75 cm thread), AMP2L22HR2620.2 (USP 2/0, HR 26 mm needle, double format 2 x 75 cm), AMP2L22HR3020.2 (USP 2/0, HR 30 mm needle, double format 2 x 75 cm), AMP2L22HR4020.2 (USP 2/0, HR 40 mm needle, double format 2 x 75 cm), as well as 3/0 and 4/0 gauges on the same HR 22 mm needle. All references are supplied in boxes of 12 units. For longer tensile support, consider the standard polyglactin 910 family (absorption 56-72 days).
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.