We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID | ½ Circle Cylindrical Needle Taperpoint Conical Point 30 mm (HR30) · USP 0 · Colourless Thread 75 cm | PREMISUT RAPID | Box of 12 units

Original price was: 39,90 €.Current price is: 30,50 €.

Absorbable multifilament suture PREMISUT RAPID (polyglactin 910 – PGLAR) with ½ circular needle of cylindrical body and Taperpoint conical point of 30 mm (HR30), USP 0 gauge and colourless grooved thread of 75 cm. Manufacturer reference 2L22HR3010. Predictable absorption by hydrolysis in 40-45 days: retains 50% of tensile strength at day 5 and loses it at day 14. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation: box of 12 units (minimum order 30 boxes), ideal for operating theatre, day hospitals and B2B supply contracts.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM2L22HR3010

Description

1. Commercial Introduction

The absorbable multifilament suture PREMISUT RAPID (Polyglactin 910 – PGLAR) is the technical choice when the procedure requires short-term wound support with predictable resorption and excellent tissue handling. This presentation mounts a ½ circular needle with cylindrical body and Taperpoint conical point of 30 mm (HR30), USP 0 gauge and colourless grooved thread of 75 cm: a combination highly valued in general and ophthalmic surgery for its atraumatic passage through lax tissues and its firm, secure knot.

Presented in a box of 12 units, it is a reliable and sterile solution for operating theatres, day hospitals, ambulatory surgery and hospital supply contracts, with advantageous conditions for centralised replenishment.

2. Technical Explanation

Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish that favours thread sliding, smooth handling and firm knotting. In its RAPID variant (low molecular weight polyglactin 910), absorption occurs by hydrolysis in 40-45 days, retaining approximately 50% of its tensile strength at 5 days and losing it completely at 14 days, making it suitable for superficial tissues, mucous membranes and temporary approximation of soft tissues where material removal is not required.

The ½ circle needle with cylindrical body and Taperpoint conical point (HR30) combines the strength of a round body with a sharp point that separates fibres without aggressive cutting effect, minimising trauma. The colourless grooved thread facilitates handling and sliding. Gamma radiation sterilisation guarantees final sterility with minimal alteration of the material’s mechanical properties. Single-use product, not re-sterilisable: check the integrity of the packaging and the expiry date before each procedure.

3. Technical Specifications

3.1. General characteristics (Ref. 2L22HR3010)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Gauge USP 0 (metric 3.5)
Thread colour Colourless
Thread length 75 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical Taperpoint (HR30)
Needle size 30 mm
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units (minimum order 30 boxes)
Manufacturer reference 2L22HR3010

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

4. Equivalences and Cross-References

Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market. This reference shares material, rapid absorption profile and ½ circle conical needle configuration with homologous lines from the main manufacturers. Only codes whose attributes have been verified in official catalogues and authorised distributors are included:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9975 (EMEA) Comparable by category (not interchangeable 1:1) Same material and rapid absorption (≈42 days), 75 cm thread, ½ circle needle of 31 mm with conical point (MH-1) and colourless colour; the gauge differs (USP 2/0 versus USP 0) and the needle size (31 mm versus 30 mm). Code confirmed in Ethicon EMEA catalogue.
Ethicon (Johnson & Johnson) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9963 (EMEA) Comparable by category (not interchangeable 1:1) Same material, rapid absorption and USP 0 gauge with ½ circle needle, but it mounts a 36 mm Tapercut trocar point (V-34) and 90 cm thread; it does not reproduce the HR30 conical point / 75 cm combination of this reference.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous ranges in the rapid absorption segment, Safil Quick / Novosyn Quick (B. Braun) and Surgicryl Fast Absorb (SMI) are listed, comparable by category by material and absorption profile, although their specific codes for the exact combination USP 0 / 30 mm Taperpoint needle / 75 cm must be confirmed with the manufacturer. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version.

5. Selection tips and variants of interest

USP 0 gauge (metric 3.5) with a 30 mm conical needle is a balanced choice for approximation of soft tissues, ligation of medium-calibre vessels and ophthalmic surgery where an atraumatic passage and brief temporary support are needed before complete resorption at 40-45 days.

Within the same PGLAR RAPID range, Cahnos offers complementary configurations: the same conical needle and gauge with a 90 cm thread length (AM2L23HR3601), the variant with Tapercut HRT36 trocar point in USP 0 of 75 cm (AM2L22HRT3610), the version with a 36 mm conical needle in USP 1 gauge (AMP2L22HR3601) and the one with HR26 needle in USP 3/0 gauge (AM2L22HR2630) for finer tissues. The minimum order is 30 boxes of 12 units, an ideal condition for centralised replenishment and supply contracts for the operating theatre service. For special B2B conditions or questions about needle selection, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), RAPID variant

Structure

Braided coated multifilament, fluted finish

Metric gauge (EP)

3.5

Needle body

Cylindrical

Needle tip

Taperpoint conical

Needle size

30 mm (HR30)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation

Use

Single-use, not re-sterilisable

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

2L22HR3010

Medida de aguja

HR 30

Usp

0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID | ½ Circle Cylindrical Needle Taperpoint Conical Point 30 mm (HR30) · USP 0 · Colourless Thread 75 cm | PREMISUT RAPID | Box of 12 units”

Your email address will not be published. Required fields are marked *