We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Polyglactin 910 RAPID Suture (PGLAR) · Needle 1/2 Circle Cylindrical Conical Point Taperpoint HR17 (17 mm) · USP 5/0 (Metric 1) · Undyed · 75 cm · PREMISUT RAPID · Box of 12 units

Original price was: 39,90 €.Current price is: 30,50 €.

Multifilament absorbable suture of Polyglactin 910 RAPID (PREMISUT RAPID) in USP 5/0 gauge, mounted with a half circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17) and undyed grooved thread of 75 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses it completely at 14 days, ideal for soft and fast-healing tissues, often without suture removal. Sterilised by gamma radiation, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation: box of 12 units (minimum order 30 boxes). Factory reference 2L22HR1750.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM2L22HR1750

Description

1. Commercial Introduction

The multifilament absorbable suture PREMISUT RAPID of polyglactin 910 (PGLAR) is the technical answer for the professional who needs a synthetic absorbable thread with predictable behaviour, excellent handling and rapid loss of strength. Its RAPID variant (low molecular weight polymer) is formulated for tissues that heal quickly and only require temporary support for 7–10 days, without the need to remove the material.

Mounted with a half circle needle, cylindrical body and Taperpoint conical point of 17 mm (HR17), it penetrates soft, well-perfused tissues by separating the fibres without tearing them, minimising trauma and bleeding at the entry point. USP 5/0 gauge, undyed thread of 75 cm. Presentation in a box of 12 sterile units, with batch traceability, ideal for operating theatres, day hospitals, ambulatory surgery and B2B supply contracts.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided and grooved multifilament structure that provides flexibility, smooth passage and great security in knot tying. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity, which guarantees uniform kinetics between individuals.

In the RAPID variant, the thread retains 50% of its tensile strength at 5 days and loses it completely at 14 days, with absorption completing between 40 and 45 days. The half circle needle (160°) with atraumatic conical point is especially recommended for lax and delicate tissues, and the undyed colour provides maximum discretion on the surgical field. Sterile single-use product, sterilised by gamma radiation and not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. 2L22HR1750 · SKU AM2L22HR1750)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant low molecular weight
Thread structure Braided coated multifilament, fluted finish
Quality Standard (PREMISUT RAPID range)
Gauge USP 5/0 (metric 1; approximate diameter 0.10 – 0.149 mm according to Pharmacopoeia)
Thread colour Colourless (undyed)
Thread length 75 cm
Needle shape ½ circle (1/2, 160°), cylindrical body
Needle tip Taperpoint conical (atraumatic)
Needle size 17 mm (HR17)
Swaged 1 needle / 1 suture per unit
Absorption mechanism Hydrolysis
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units (minimum order 30 boxes)

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption Polyglactin 910 (absorption 56 – 72 days), also available in our catalogue.

3.3. Gauge equivalence (USP Pharmacopoeia)

USP size Metric size Approximate diameter
5/0 (this product) 1 0.10 – 0.149 mm
4/0 1.5 0.15 – 0.199 mm
3/0 2 0.20 – 0.249 mm

3.4. Reference code decoding

The official reference 2L22HR1750 breaks down as follows: 2L22 (75 cm thread in the PGLAR family) + HR17 (half circle needle with cylindrical body and Taperpoint conical point of 17 mm) + 50 (USP 5/0 gauge). Cahnos markets the official reference without altering characters: no digit may be added, removed or rearranged when ordering or tendering.

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. At category level, rapid absorption Polyglactin 910 (low molecular weight) is the most widespread rapid-action braided multifilament absorbable in the surgical market, whose international clinical reference is the VICRYL RAPIDE™ family from Ethicon / J&J MedTech, with which it shares composition (90% glycolide / 10% L-lactide), hydrolysis absorption mechanism and accelerated strength loss profile. Only codes whose attributes have been verified in the manufacturer’s official catalogue and authorised distributors are included; none is interchangeable 1:1 without technical validation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon / J&J MedTech VICRYL RAPIDE™ (braided polyglactin 910, colourless) W9969 – USP 5/0, RB-1 needle of 17 mm in half circle, taper point Taperpoint, colourless thread of 75 cm Comparable by category (not interchangeable 1:1) Almost total match of attributes: same material and accelerated absorption profile (≈50% at 5 days / 0% at 14 days), USP 5/0 gauge (metric 1), half circle curvature, 17 mm conical point needle, undyed 75 cm thread; they differ in the needle profile nomenclature (RB-1 vs HR17), the braid coating and the presentation format. Code confirmed in Ethicon catalogue and authorised distribution; verify official datasheet before substituting.

As homologous ranges in the rapid absorption segment, Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) are listed, comparable by category by material and absorption profile, although their specific codes for the exact combination USP 5/0 / HR17 conical point needle / 75 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56 – 72 days) is not comparable to this RAPID version.

5. Selection tips and variants of interest

Before substituting this reference for another, verify three fields against the service protocol: thread gauge (USP 5/0, metric 1), needle curvature and length (half circle, 17 mm) and point type (Taperpoint conical). Gauge 5/0 is ideal for fine and delicate tissues: thin skin, mucous membranes, conjunctiva, ophthalmic surgery, paediatric surgery and superficial approximations where an atraumatic passage and reabsorption without suture removal are sought.

SKU Variant
AM2L22HR1750 (2L22HR1750) PGLAR RAPID, HR17 taper point needle, USP 5/0, colourless, 75 cm (this product)
AMP2L22HR1750 (P2L22HR1750) PGLAR RAPID Prime, same needle and gauge, USP 5/0, colourless, 75 cm (Prime range)
AM2L22HR1730 (2L22HR1730) PGLAR RAPID, HR17 taper point needle, USP 3/0, colourless, 75 cm (larger gauge)
AMP2L22HR1740 (P2L22HR1740) PGLAR RAPID Prime, HR17 needle, USP 4/0, colourless, 75 cm
AM2L22DS1650 (2L22DS1650) PGLAR RAPID, ⅜ circle reverse cutting needle DS16, USP 5/0, colourless, 75 cm (for firm tissues)

The undyed version offers maximum aesthetic discretion on the surgical field; if greater visibility is required, request the same configuration in dyed thread on demand. If the tissue is firm, the reverse cutting triangular needle family (DS/HS) is the natural alternative; if the protocol requires longer tensile support (56 – 72 days), consider the PGLAR range of standard polyglactin 910. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant

Structure

Braided coated multifilament, fluted finish

Gauge

USP 5/0 (metric 1)

Thread diameter

0.10 – 0.149 mm

Colour

Colourless (undyed)

Needle shape

½ circle (1/2, 160°), cylindrical body

Needle tip

Taperpoint conical (atraumatic)

Needle size

17 mm (HR17)

Absorption

By hydrolysis, complete at 40 – 45 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

2L22HR1750

Use

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HR 17

Usp

5/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Polyglactin 910 RAPID Suture (PGLAR) · Needle 1/2 Circle Cylindrical Conical Point Taperpoint HR17 (17 mm) · USP 5/0 (Metric 1) · Undyed · 75 cm · PREMISUT RAPID · Box of 12 units”

Your email address will not be published. Required fields are marked *