Multifilament Absorbable Suture Polyglactin 910 RAPID Prime – ½-Circle Needle Cylindrical Body Blunt Point (HRN36) 36 mm – USP 2/0 (Metric 3) – Colourless Thread 90 cm – Ref. P2L23HRN3620 – Box 12 units

Original price was: 47,04 €.Current price is: 34,80 €.

Multifilament absorbable suture PREMISUT RAPID of Polyglactin 910 in Prime quality, with a ½-circle needle of cylindrical body and atraumatic blunt point of 36 mm (HRN36). USP size 2/0 (metric 3), colourless grooved thread of 90 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50 % of tensile strength on day 5 and loses it on day 14. Sterilised by gamma radiation, single-use, with minimal tissue reaction, smooth passage and secure knot. Especially indicated for approximation of soft tissues, ligatures and ophthalmic surgery. Reference P2L23HRN3620 · Box of 12 units (minimum order 30 boxes).

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L23HRN3620

Description

1. Commercial Introduction

The absorbable multifilament suture PREMISUT RAPID Polyglactin 910 (PGLAR) in Prime quality is the technical choice when the procedure requires short-term wound support, fully predictable reabsorption and excellent tissue handling. Its ½ circle 36 mm needle with cylindrical body and blunt point (Blunt Point) passes through soft tissues separating the fibres without cutting effect, a quality especially valued in ophthalmic surgery, ligation of small-calibre vessels and approximation of superficial tissues. Presented in a box of 12 sterile units, it is a reliable and cost-effective solution for operating theatres, day hospitals, ambulatory major surgery and hospital supply contracts, with a minimum order of 30 boxes.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish that provides flexibility, low shape memory, smooth passage through tissue and firm, secure knot tying. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days. This short support window makes it suitable for rapidly healing tissues and where residual foreign material is to be minimised. The ½ circle blunt point HRN36 needle offers maximum atraumatic penetration: its rounded tip displaces fibres without tearing them, reducing tissue trauma and haemorrhage in vascular beds. The undyed thread facilitates its aesthetic use in superficial planes and in ophthalmology. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.

3. Technical Specifications

Material Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID)
Thread structure Braided coated multifilament, fluted finish
Family / version PGLAR – RAPID (rapid absorption), Prime quality (PREMISUT RAPID)
Gauge USP 2/0 (metric 3); indicative diameter 0.30–0.339 mm
Thread colour Colourless
Thread length 90 cm
Needle shape ½ circle (1/2, 160°), cylindrical body
Needle tip Blunt point (Blunt Point), atraumatic
Needle size 36 mm (HRN36 Prime)
Absorption mechanism Hydrolysis; complete between 40 and 45 days
Residual tensile strength 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Manufacturer reference P2L23HRN3620
Commercial format Box of 12 units (minimum order 30 boxes)
Tensile strength retention profile
Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Total absorption 40–45 days, by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread category of absorbable multifilament suture in the surgical market. This reference shares material, USP 2/0 gauge, ½ circle curvature, 36 mm cylindrical needle, 90 cm undyed thread and rapid absorption profile with the homologous line of the sector’s leading manufacturer. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and in authorised distributor sources is included:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) V9450H (EMEA) Comparable by category (not interchangeable 1:1) They match: material and rapid absorption (≈42 days), USP 2/0 gauge, 90 cm undyed thread and ½ circle 36 mm needle with atraumatic passage (CT-1 PLUS / Taperpoint). They differ: the tip is conical (Taperpoint) versus the blunt point (Blunt Point) HRN36 of this reference, the braid coating (calcium stearate) and the packaging format (36 units in Ethicon). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors.

Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments of poly(glycolide-co-L-lactide) with short-term tensile strength retention; they are not included in the table because no verified code is available for the exact combination USP 2/0 / 36 mm needle / blunt point Blunt Point / 90 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

The USP 2/0 (metric 3) gauge offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small-calibre vessels. The blunt point needle is the most atraumatic option in the catalogue: its rounded tip minimises tissue damage and haemorrhage, being the first choice in ophthalmic surgery, lax tissues and vascularised beds. Within the same HRN36 family (blunt point, 90 cm thread), Cahnos offers the PGAR RAPID version in polyglycolic acid (ref. AMP223HRN3620) with identical needle geometry. If the protocol prefers atraumatic Ultra Plus conical point, consult the HRP36 Prime family (ref. AMP2L23HRP3620); for standard Taperpoint conical point, the HR36 family (ref. AMP2L23HR3620, and double thread in AMP2L23HR3620.2); and if the tissue is somewhat firmer and requires greater penetration without cutting, consider the Tapercut trocar point HRT36 (ref. AMP2L23HRT3620). For longer tensile support, the PGLA family of standard polyglactin 910 (absorption 56–72 days). The undyed version offers maximum discretion in the field; if greater visibility is required, consider the same configuration in dyed thread on demand. As it is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Gauge

USP 2/0 (metric 3); diameter 0.30–0.339 mm

Needle shape

½ circle (1/2, 160°), cylindrical body

Needle tip

Blunt point (Blunt Point), atraumatic

Needle size

36 mm (HRN36 Prime)

Absorption

By hydrolysis, complete in 40–45 days

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Manufacturer reference

P2L23HRN3620

Presentation

Box of 12 units (minimum order 30 boxes)

Medida de aguja

HRN 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Blunt tip

Forma de aguja

1/2 circle

Calidad sutura

Prime