We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime – Needle ½ Circle Reverse Cutting Triangular Point 36 mm, USP 2/0, Colourless Thread 90 cm (PREMISUT PGLAR)

Original price was: 43,58 €.Current price is: 34,80 €.

Absorbable multifilament suture PREMISUT RAPID Prime of Polyglactin 910 (PGLAR PRIME), in USP 2/0 gauge, with ½ circle needle with reverse cutting triangular point of 36 mm and colourless grooved thread of 90 cm. Copolymer of 90% glycolide and 10% L-lactide, with hydrolysis absorption between 40 and 45 days, retention of 50% tensile strength at 5 days and total loss at 14 days. Sterilised by gamma radiation, single use and minimal tissue reaction; indicated for tissue approximation, ligatures and ophthalmic surgery. Sold by box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L23HS3620

Description

The Absorbable Multifilament Suture PREMISUT RAPID Prime, manufactured in Polyglactin 910 (PGLAR PRIME), is the technical choice for professionals who need controlled and rapid reabsorption with excellent handling. Its colourless grooved multifilament structure offers smooth sliding, secure knot tying and minimal tissue reaction, ideal for soft tissue procedures, ligatures and ophthalmic surgery where short-term support is required.

Technical explanation

Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide that is absorbed by hydrolysis. The RAPID version is characterised by an accelerated loss of strength: it retains 50% of its tensile strength at 5 days and loses it completely at 14 days, with total absorption between 40 and 45 days. The ½ circle needle with reverse cutting triangular point penetrates firm, inelastic tissues with minimal trauma, while the USP 2/0 gauge provides an optimal balance between handling and strength for medium-thickness sutures.

Technical specifications

Material Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), PGLAR PRIME
Thread type Braided multifilament, colourless
Gauge USP 2/0
Needle ½ circle (1/2), reverse cutting triangular point, 36 mm
Thread length 90 cm
Absorption By hydrolysis between 40 and 45 days
Strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation (single-use)
Presentation Box of 12 units (minimum order 30 boxes)
Reference SKU AMP2L23HS3620

Equivalences and cross-references

Rapid-absorption Polyglactin 910 is a standardised category whose international clinical reference is the VICRYL RAPIDE line from Ethicon (J&J MedTech), with which it shares composition (90% glycolide / 10% L-lactide), absorption profile and resistance loss profile. Below are references verified from public manufacturer sources:

Manufacturer / Brand Family / Model Reference code Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE VR917 Comparable by category (not interchangeable 1:1) USP 2/0 colourless, 90 cm, ½ circle V-34 needle of 36 mm; differs in point type (tapercut vs. reverse cutting).
Ethicon (J&J MedTech) VICRYL RAPIDE VR945 Comparable by category (not interchangeable 1:1) USP 2/0 colourless, 90 cm, ½ circle CT-1 needle of 36 mm; tapered point, designed for soft tissues, as opposed to reverse cutting.
Ethicon (J&J MedTech) VICRYL RAPIDE VR932 Comparable by category (not interchangeable 1:1) USP 2/0 colourless; ½ circle CT-1/CP-1 needle of 36 mm with double needle and 135 cm of thread; length and configuration differ.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The selection between tapered point, tapercut or reverse cutting must be based on the tissue to be sutured: the reverse cutting triangular point is oriented towards firm, low-elasticity tissues.

Selection tips and variants of interest

For soft, easily penetrable tissues, the cylindrical needle series with tapered point (HR, taperpoint) is recommended; for denser tissues, the reverse cutting triangular point of this model or the trocar point variant (HRT, tapercut) when greater penetration firmness is required without enlarging the exit hole. The PGLAR RAPID range is available in additional gauges, thread lengths and needle sizes (22, 26 and 30 mm), in single or double thread versions and in Prime quality, allowing the suture to be adapted to the procedure and budget of each centre. Always verify the gauge, needle geometry and length required in the surgical report before placing the order.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide)

Quality

Prime (PGLAR PRIME)

Gauge

USP 2/0

Thread type

Braided multifilament, colourless

Needle tip

Triangular reverse cutting (reverse cutting)

Needle size

36 mm

Sterilisation

Gamma radiation (single-use)

Presentation

Box of 12 units (minimum order 30 boxes)

Indications

Tissue approximation, ligatures and ophthalmic surgery

Reference

AMP2L23HS3620

Medida de aguja

HS 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime – Needle ½ Circle Reverse Cutting Triangular Point 36 mm, USP 2/0, Colourless Thread 90 cm (PREMISUT PGLAR)”

Your email address will not be published. Required fields are marked *