We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Prime | Straight Needle Taperpoint Conical Point GR 48 mm | Gauge USP 3/0 (Metric 2) | Violet Thread 70 cm | Ref. P1L18GR4830 – Box of 12 units

Original price was: 39,90 €.Current price is: 29,90 €.

Absorbable suture PREMISUT of Polyglactin 910 (PGLA) in Prime quality, with a straight needle with cylindrical body and Taperpoint conical point of 48 mm (GR48), USP 3/0 (metric 2) gauge and a violet braided thread of 70 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L18GR4830, presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18GR4830

Description

1. Introduction

At Cahnos we offer the absorbable multifilament Polyglactin 910 (PGLA) suture in Prime quality from the Premisut range, reference P1L18GR4830, designed for the professional who demands reliable, manageable and predictable performance in the operating theatre. This presentation combines a straight needle with a cylindrical body and a conical point of 48 mm (GR48), USP 3/0 (metric 2) and a violet thread of 70 cm with high visibility on tissue.

It is an excellent option for the approximation of soft tissues, ligatures and ophthalmic surgery, with predictable absorption that avoids the need for removal. It is supplied in a box of 12 units, sterile by ethylene oxide and ready for immediate use in the operating theatre, with special conditions for hospital B2B supply.

2. Technical explanation

Polyglactin 910 is a synthetic copolymer composed of 90 % glycolide and 10 % L-lactide, structured as a braided multifilament that ensures smooth passage through tissue, excellent knot tying and high initial tensile strength. Its absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable interval of 56 to 72 days, with progressive loss of strength and minimal tissue reaction.

The straight needle with cylindrical body and conical point (Taperpoint) of 48 mm passes through tissue separating the fibres without cutting them, minimising trauma to delicate structures and facilitating manual suturing on directly accessible surfaces. The violet colour ensures optimal visibility of the thread throughout the procedure. The product is supplied sterile by ethylene oxide (EO), is single-use and does not allow re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet for reference P1L18GR4830

Characteristic Specification
Reference (SKU) P1L18GR4830
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Multifilament braided coated (fluted)
Gauge USP 3/0 (metric 2)
Thread length 70 cm
Thread colour Violet (colourless version available in the family)
Needle shape Straight
Needle body Cylindrical
Needle tip Conical (Taperpoint)
Needle size 48 mm (GR 48 Prime)
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention and absorption profile

Period Tensile strength retention
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56 – 72 days, by hydrolysis

Minimal tissue reaction, excellent tensile strength and knot tying capability, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

This multifilament Polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures of medium absorption on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided coated polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic (Covidien) Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with straight needles (series 4xxxx)

The straight needle, cylindrical body and conical point (Taperpoint) of 48 mm is functionally equivalent to the atraumatic conical needles used by the main manufacturers for manual suturing on delicate tissues. Within the Cahnos catalogue, its direct equivalent in polyglycolic acid with the same needle geometry is reference AMP118GR4830 (PGA Prime, absorption 60-90 days). The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most appropriate suture, consider the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 3/0 (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The straight needle with conical point of 48 mm (GR48) is especially suitable for the approximation of soft tissues and for ophthalmic surgery in areas of limited access, where atraumatic penetration is prioritised.

Variants of interest in the Cahnos catalogue:

  • P1L18HR4830: same Prime quality and gauge 3/0 with a 1/2 circle HR 48 mm needle, violet, 70 cm (curved needle radius for other techniques).
  • P1L18GR1930: PGLA Prime, straight needle GR 19 mm, USP 3/0, violet, 70 cm (shorter needle for precision areas).
  • P1L18GR1940: PGLA Prime, straight needle GR 19 mm, USP 4/0, violet, 70 cm (finer gauge for delicate tissues).
  • P1L18HR4030: PGLA Prime, 1/2 circle HR 40 mm needle, USP 3/0, violet, 70 cm (smaller needle radius).
  • AMP118GR4830: alternative in polyglycolic acid (PGA) with the same straight needle GR 48 mm, USP 3/0, violet, 70 cm, absorption 60-90 days.

As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other commercial houses, please consult our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Structure

Coated braided multifilament

USP size

3/0 (metric 2)

Needle type

Straight, cylindrical body, Taperpoint conical point

Needle size

48 mm (GR 48 Prime)

Tensile strength

75% at 2 weeks, 50% at 3 weeks, 30% at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Quality

Prime (PREMISUT)

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

GR 48

Usp

3/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

Straight Cut

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Prime | Straight Needle Taperpoint Conical Point GR 48 mm | Gauge USP 3/0 (Metric 2) | Violet Thread 70 cm | Ref. P1L18GR4830 – Box of 12 units”

Your email address will not be published. Required fields are marked *