Description
1. Commercial Introduction
The absorbable multifilament suture of poliglactina 910 (PGLA) from the Premisut range, reference 1L13HR4502, is the reference surgical closure solution for the professional who demands a flexible, resistant thread with a totally predictable absorption behaviour in the operating theatre. Its ½ circle needle with cylindrical body and conical point Taperpoint of 45 mm (HR45) passes through soft tissues separating the fibres without tearing them, minimising trauma and being especially suitable for tissue approximation, ligatures and ophthalmic surgery.
It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for B2B procurement of hospitals, ophthalmic clinics, private operating theatres and purchasing centres. It is presented in a box of 12 units with a minimum order of 30 boxes, which guarantees the continuous and traceable supply of your healthcare centre.
2. Technical explanation
Poliglactina 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that favours the passage of the thread through the tissue, very smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 2 (metric 5).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with conical Taperpoint point penetrates by separating the fibres without cutting them, and the violet colouration ensures optimal visibility of the thread on the surgical field. The product is supplied sterile by ethylene oxide, single-use and without the possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference 1L13HR4502
| Characteristic | Specification |
| Reference (SKU) | 1L13HR4502 |
| Brand / Range | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2 (metric 5) |
| Thread colour | Violet (also available colourless) |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | HR 45 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Time after implantation | Retained tensile strength |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days (by hydrolysis) |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
Poliglactina 910 is one of the most widely used synthetic absorbable materials in the European market. This reference is clinically comparable, in terms of composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (TC / HR series) |
Within the Cahnos catalogue, its direct equivalent in the same HR 45 mm needle configuration, USP 2 gauge and violet thread in superior quality is reference P1L13HR4502 (Prime quality), and in double thread format P1L13HR4502.2 (2 x 90 cm). As an alternative in polyglycolic acid (PGA) with the same needle geometry, reference AM113HR4502 is available (absorption 60-90 days). The indicated equivalences are indicative; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most appropriate suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. The USP 2 (metric 5) gauge is indicated for tissues that require greater initial resistance: deep planes, fascia, aponeurosis, high-tension closures and ligatures. The conical Taperpoint point is ideal for soft and friable tissues; for fibrous tissues or the sclera, trocar or reverse cutting points are recommended.
| Reference | Variant |
| 1L13HR4502 | PGLA USP 2, HR 45 mm needle, violet, 90 cm (current product) |
| P1L13HR4502 | PGLA Prime quality, USP 2, HR 45 mm needle, violet, 90 cm (superior range) |
| P1L13HR4502.2 | PGLA Prime, USP 2, HR 45 mm needle, violet, 2 x 90 cm (higher performance) |
| 1L18HR4502 | PGLA USP 2, HR 45 mm needle, violet, 70 cm (shorter thread length) |
| 1L13HR4501 | PGLA USP 1, HR 45 mm needle, violet, 90 cm (smaller gauge) |
| 1L13HR4002 | PGLA USP 2, HR 40 mm needle, violet, 90 cm (shorter needle) |
| 1L13HR4802 | PGLA USP 2, HR 48 mm needle, violet, 90 cm (longer needle) |
| 1L23HR4802 | PGLA USP 2, HR 48 mm needle, colourless thread, 90 cm (maximum aesthetic discretion) |
| AM113HR4502 | PGA USP 2, HR 45 mm needle, violet, 90 cm (polyglycolic acid alternative, absorption 60-90 days) |
All references are supplied in a box of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact our technical-commercial team.





Reviews