Description
1. Commercial Introduction
The multifilament absorbable suture of Polyglactin 910 (PGLA) reference 1L22DS1930 is the reference technical choice for the professional seeking a surgical thread with predictable performance, excellent handling and great knot security in tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circle needle with reverse cutting triangular point of 19 mm (DS 19) offers firm and controlled penetration, ideal for firm tissues and delicate structures, while the 75 cm undyed braided thread facilitates visualisation of the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement in operating theatres, ophthalmology practices, purchasing centres and distributors. Commercial presentation in a box of 12 units with a minimum order of 30 boxes.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure and coated with an undyed grooved finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine calibres such as USP 3/0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture suitable for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point (inverted triangle) of 19 mm penetrates firm tissues with controlled trauma, avoiding tears, being especially indicated in ophthalmic surgery, tissue approximation and ligatures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 1L22DS1930
| Characteristic | Specification |
| Reference (SKU) | 1L22DS1930 (PREMISUT range) |
| Thread structure | Braided coated multifilament, fluted finish |
| Composition | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread size | USP 3/0 (metric 2) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Needle size | 19 mm (DS 19) |
| Tip type | Reverse cutting triangular (inverted triangular) |
| Colour and finish | Undyed grooved (also available in violet) |
| Absorption | By hydrolysis between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal, with excellent tensile strength and optimal knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Sold in boxes of 12 units.
4. Equivalences and Cross-References
PREMISUT Polyglactin 910 is clinically equivalent to the absorbable braided polyglactin 910 sutures from the main international manufacturers, which facilitates its incorporation into purchasing centres, tenders and operating theatre protocols:
| Manufacturer / commercial house | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910) |
| B. Braun | Safil (braided and coated polyglactin 910, equivalent retention and absorption profile) |
| Medtronic | Absorbable braided polyglactin 910 range |
| Laboratory Aragó | Range of polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in configuration (PGLA 3/0, DS 19 needle, 75 cm) is reference 1L12DS1930 in violet grooved colour. The 4/0 calibre version (1L22DS1940 undyed and 1L12DS1940 violet), the variants with 16 mm needle (1L22DS1640 and 1L22DS1650) and the PGLAR rapid absorption line (AM2L22DS1930) complete the rest of ophthalmic and soft tissue needs.
5. Selection tips and variants of interest
The USP 3/0 calibre is ideal for skin, subcutaneous tissue, low-tension soft tissues, ligatures and superficial ophthalmic sutures. The ⅜ needle with reverse cutting triangular point is indicated when firm tissues need to be penetrated without tearing, with an atraumatic passage highly valued in ophthalmology. The undyed colour is preferable when minimising thread visibility is of interest; if maximum visibility is sought, the violet version exists. For very fast-healing tissues, consider the PGLAR rapid absorption line (40-45 days).
| Reference | Variant |
| 1L22DS1930 | PGLA USP 3/0, ⅜ triangular needle DS 19 mm, undyed, 75 cm (current product) |
| 1L12DS1930 | PGLA USP 3/0, same DS 19 mm needle, violet, 75 cm (violet variant) |
| 1L22DS1940 | PGLA USP 4/0, triangular DS 19 mm needle, undyed, 75 cm (finer calibre) |
| 1L12DS1940 | PGLA USP 4/0, triangular needle DS 19 mm, violet, 75 cm (finer gauge) |
| 1L22DS1640 | PGLA USP 4/0, triangular DS 16 mm needle, undyed, 75 cm (shorter needle) |
| 1L22DS1650 | PGLA USP 5/0, triangular DS 16 mm needle, undyed, 75 cm (shorter needle) |
| AM2L22DS1930 | PGLAR rapid absorption (40-45 days), USP 3/0, DS 19 mm, undyed, 75 cm |
| AM122DS1930 | PGA USP 3/0, ⅜ triangular DS 19 mm needle, undyed, 75 cm (absorption 60 to 90 days) |
All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.





Reviews