We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PREMISUT PGLA 910 | 3/8 Circle Needle Reverse Cutting Triangular Point DS19 mm | USP 3/0 (Metric 2) | Undyed Thread 75 cm | Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Multifilament absorbable suture PREMISUT of Polyglactin 910 (PGLA), reference 1L22DS1930, with ⅜ circle needle with reverse cutting triangular point of 19 mm (DS19), USP 3/0 calibre and braided thread undyed grooved of 75 cm. Predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Equivalent to Vicryl (Ethicon) and Safil (B. Braun). Presentation in a box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L22DS1930

Description

1. Commercial Introduction

The multifilament absorbable suture of Polyglactin 910 (PGLA) reference 1L22DS1930 is the reference technical choice for the professional seeking a surgical thread with predictable performance, excellent handling and great knot security in tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circle needle with reverse cutting triangular point of 19 mm (DS 19) offers firm and controlled penetration, ideal for firm tissues and delicate structures, while the 75 cm undyed braided thread facilitates visualisation of the surgical field and smooth sliding during suturing.

It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement in operating theatres, ophthalmology practices, purchasing centres and distributors. Commercial presentation in a box of 12 units with a minimum order of 30 boxes.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure and coated with an undyed grooved finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine calibres such as USP 3/0.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture suitable for tissues requiring wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point (inverted triangle) of 19 mm penetrates firm tissues with controlled trauma, avoiding tears, being especially indicated in ophthalmic surgery, tissue approximation and ligatures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference 1L22DS1930

Characteristic Specification
Reference (SKU) 1L22DS1930 (PREMISUT range)
Thread structure Braided coated multifilament, fluted finish
Composition Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread size USP 3/0 (metric 2)
Thread length 75 cm
Needle shape ⅜ circle
Needle size 19 mm (DS 19)
Tip type Reverse cutting triangular (inverted triangular)
Colour and finish Undyed grooved (also available in violet)
Absorption By hydrolysis between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and optimal knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Sold in boxes of 12 units.

4. Equivalences and Cross-References

PREMISUT Polyglactin 910 is clinically equivalent to the absorbable braided polyglactin 910 sutures from the main international manufacturers, which facilitates its incorporation into purchasing centres, tenders and operating theatre protocols:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910)
B. Braun Safil (braided and coated polyglactin 910, equivalent retention and absorption profile)
Medtronic Absorbable braided polyglactin 910 range
Laboratory Aragó Range of polyglactin 910 with ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent in configuration (PGLA 3/0, DS 19 needle, 75 cm) is reference 1L12DS1930 in violet grooved colour. The 4/0 calibre version (1L22DS1940 undyed and 1L12DS1940 violet), the variants with 16 mm needle (1L22DS1640 and 1L22DS1650) and the PGLAR rapid absorption line (AM2L22DS1930) complete the rest of ophthalmic and soft tissue needs.

5. Selection tips and variants of interest

The USP 3/0 calibre is ideal for skin, subcutaneous tissue, low-tension soft tissues, ligatures and superficial ophthalmic sutures. The ⅜ needle with reverse cutting triangular point is indicated when firm tissues need to be penetrated without tearing, with an atraumatic passage highly valued in ophthalmology. The undyed colour is preferable when minimising thread visibility is of interest; if maximum visibility is sought, the violet version exists. For very fast-healing tissues, consider the PGLAR rapid absorption line (40-45 days).

Reference Variant
1L22DS1930 PGLA USP 3/0, ⅜ triangular needle DS 19 mm, undyed, 75 cm (current product)
1L12DS1930 PGLA USP 3/0, same DS 19 mm needle, violet, 75 cm (violet variant)
1L22DS1940 PGLA USP 4/0, triangular DS 19 mm needle, undyed, 75 cm (finer calibre)
1L12DS1940 PGLA USP 4/0, triangular needle DS 19 mm, violet, 75 cm (finer gauge)
1L22DS1640 PGLA USP 4/0, triangular DS 16 mm needle, undyed, 75 cm (shorter needle)
1L22DS1650 PGLA USP 5/0, triangular DS 16 mm needle, undyed, 75 cm (shorter needle)
AM2L22DS1930 PGLAR rapid absorption (40-45 days), USP 3/0, DS 19 mm, undyed, 75 cm
AM122DS1930 PGA USP 3/0, ⅜ triangular DS 19 mm needle, undyed, 75 cm (absorption 60 to 90 days)

All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.

Additional information

Reference

1L22DS1930

Material

Polyglactin 910 (PGLA)

Structure

Braided coated multifilament, fluted finish

Composition

Copolymer of 90% glycolide and 10% L-lactide

Suture length

USP 3/0 (metric 2)

Needle size

19 mm (DS 19)

Tip type

Reverse cutting triangular (inverted triangular)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Medida de aguja

DS 19

Usp

3/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews