We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture Polyglactin 910 (PGLA) Prime Fine – Needle 3/8 Circle Triangular Point Reverse Cutting DS19 (19 mm), USP 4/0 Violet, 70 cm – Box of 12 units – Ref. P1L18DS1940FN

Original price was: 44,90 €.Current price is: 37,00 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime Fine quality, mounted on a ⅜ circle needle with reverse cutting triangular point of 19 mm (DS19). USP 4/0 (metric 1.5) gauge, 70 cm smooth violet thread with maximum visibility in the surgical field. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use and minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L18DS1940FN, presentation in box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18DS1940FN

Description

The absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime Fine quality, reference P1L18DS1940FN, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, minor surgery practices and purchasing centres. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and great knot security in tissue approximation, ligatures and ophthalmic surgery.

Its ⅜ circle needle with reverse cutting triangular point, 19 mm (DS19) in Fine version, ensures firm and controlled penetration even in fine and non-compliant tissues, while the 70 cm violet smooth thread offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and non-resterilisable, with an excellent quality-price ratio for the continuous supply of your centre.

Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a smooth finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 4/0 (metric 1.5).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own strength.

The ⅜ circle needle with reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears; it is therefore especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The violet colour facilitates tracking of the thread throughout the procedure. The product is supplied sterile by ethylene oxide and must not be resterilised.

Technical specifications

Technical data sheet for reference P1L18DS1940FN

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Reference (SKU) P1L18DS1940FN
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament, non-ribbed
Gauge USP 4/0 (metric 1.5)
Thread colour Violet
Thread length 70 cm
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS19 (19 mm) Fine Prime
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units

Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56 – 72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units; minimum order of 30 boxes for institutional supply.

Gauge equivalence

USP size Metric size Approximate diameter
4/0 1.5 0.15 – 0.199 mm (indicative according to Pharmacopoeia)

Equivalences and cross-references

Polyglactin 910 is the most widely used medium-duration absorbable multifilament on the surgical market. This PREMISUT Prime suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided coated polyglactin 910, violet or colourless)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratorio Aragó (Premisut range) Braided multifilament polyglactin 910 with ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent in colourless with the same configuration (triangular needle DS19 mm Fine, USP 4/0, 70 cm) is reference P1L28DS1940FN, and the violet 45 cm variant is P1L11DS1940FN. In the polyglycolic acid (PGA) family with longer absorption (60-90 days), reference AMP118DS1940FN stands out. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

Selection tips and variants of interest

To choose the most appropriate suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 4/0 (metric 1.5) gauge is indicated for fine and delicate tissues: skin, mucosa, subcutaneous tissue and ophthalmic surgery procedures. The reverse cutting triangular point needle (DS19 Fine) is especially recommended in firm or difficult-to-penetrate tissues, where the needle passage must be clean and without tearing.

Reference Variant
P1L18DS1940FN PGLA Prime, DS19 mm Fine needle, USP 4/0, violet, 70 cm (current product)
P1L28DS1940FN PGLA Prime, same DS19 mm Fine needle, USP 4/0, colourless, 70 cm (maximum discretion)
P1L11DS1940FN PGLA Prime, DS19 mm Fine needle, USP 4/0, violet, 45 cm (shorter length)
P1L21DS1940FN PGLA Prime, DS19 mm Fine needle, USP 4/0, colourless, 45 cm (shorter length)
P1L12DS1940 PGLA Prime, DS19 mm needle, USP 4/0, violet, 75 cm (standard needle, longer length)
P1L22DS1940 PGLA Prime, DS19 mm needle, USP 4/0, colourless, 75 cm (standard needle)
P1L18DS2440 PGLA Prime, DS24 mm needle, USP 4/0, violet, 70 cm (larger needle)
P1L18GR1940 PGLA Prime, straight GR 19 mm needle, USP 4/0, violet, 70 cm (straight conical needle)
AMP118DS1940FN PGA Prime, DS19 mm Fine needle, USP 4/0, violet, 70 cm (absorption from 60 to 90 days)

For maximum visibility in the field, the violet version is the most suitable; if greater aesthetic discretion is preferred, the same reference can be requested in colourless. If your protocol requires a longer tensile support (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions and volume orders, contact our technical-commercial team at Cahnos.

Additional information

Reference

P1L18DS1940FN

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Non-grooved braided multifilament

Gauge

USP 4/0 (metric 1.5)

Tip type

Triangular reverse cutting (Reverse Cutting)

Needle size

DS19 (19 mm) Fine Prime

Strength retention

75% (2 weeks), 50% (3 weeks), 30% (4 weeks)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Presentation

Box of 12 units

Indications

Tissue approximation, ligatures and ophthalmic surgery

Minimum order

30 boxes

Medida de aguja

DS 19

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture Polyglactin 910 (PGLA) Prime Fine – Needle 3/8 Circle Triangular Point Reverse Cutting DS19 (19 mm), USP 4/0 Violet, 70 cm – Box of 12 units – Ref. P1L18DS1940FN”

Your email address will not be published. Required fields are marked *