Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 0 gauge, with a ½ circle needle with a grooved taper point of 25 mm (HR25 Prime profile) and a blue thread of 75 cm, is the classic option for approximating soft tissues, ligatures and high-demand procedures: cardiovascular surgery, ophthalmology and neurosurgery.
It is supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. It is marketed under the factory reference P732HR2510 (SKU Cahnos AMP732HR2510), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (polymer of propylene, (C3H6)n) presented as an uncoated monofilament, dyed blue for maximum visibility in the surgical field. As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The HR25 Prime needle (½ circle, cylindrical body and grooved Taperpoint conical point of 25 mm) separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The grooved finish of the needle body improves grip in the needle holder and facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Line | PREMISUT Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per pack) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Needle type | Taper point, grooved |
| Needle size | 25 mm (HR25 Prime profile) |
| Manufacturing quality | Prime (improved penetration needle) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P732HR2510 |
| Reference Cahnos (SKU) | AMP732HR2510 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm |
3.3. Variants of the HR25 Prime family (½ circle, Taperpoint conical point, 25 mm needle)
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| HR25 Prime | 0 | 1 × 75 cm | P732HR2510 / AMP732HR2510 (this product) |
| HR25 Prime | 0 | 2 × 75 cm | P732HR2510.2 / AMP732HR2510.2 |
| HR25 Prime | 1 | 2 × 75 cm | P732HR2501.2 / AMP732HR2501.2 |
| HR25 Prime | 4/0 | 1 × 75 cm | P732HR2540 / AMP732HR2540 |
| HR25 Prime | 5/0 | 1 × 75 cm | P732HR2550 / AMP732HR2550 |
| HR25 (standard) | 0 | 1 × 75 cm | 732HR2510 / AM732HR2510 |
4. Equivalences and Cross-References
The reference P732HR2510 corresponds to the official nomenclature of the PREMISUT Prime range (grooved HR25 Prime profile, single 75 cm thread, USP 0 gauge, blue colour), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tender or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (PREMISUT Prime) | Polypropylene HR25 Prime, USP 0, blue, 1 × 75 cm | P732HR2510 / AMP732HR2510 | Exact reference equivalence (current product) | Official reference of the analysed product |
| Cahnos (PREMISUT Prime) | Polypropylene HR25 Prime, USP 0, blue, 2 × 75 cm | P732HR2510.2 / AMP732HR2510.2 | Configuration equivalent within the same system | Same grooved HR25 needle and USP 0 gauge; the presentation changes to double thread |
| Cahnos (PREMISUT standard) | Polypropylene HR25, USP 0, blue, 1 × 75 cm | 732HR2510 / AM732HR2510 | Direct equivalent within the same family | Same dimensions and material; standard quality needle versus Prime |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0 | NW846 (blue, 90 cm, ½ circle taper point RB needle, 30 mm) | Comparable by category (not interchangeable 1:1) | Same material, gauge and colour; thread length (90 cm) and needle (30 mm) differ from the 25 mm HR25. Verified in official Ethicon catalogue |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene monofilament, ½ circle taper point | CP-424 (USP 0, blue, 75 cm, GS-21 needle, 37 mm) | Comparable by category (not interchangeable 1:1) | Same gauge and taper point; copolymer material and 37 mm needle versus 25 mm. Verify in official Medtronic catalogue |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, ½ circle needle | C2095443 (USP 0, 75 cm, ½ circle needle, 26 mm) | Comparable by category (not interchangeable 1:1) | Material, gauge, colour and length (75 cm) match; 26 mm needle versus the 25 mm taper point HR25. Verified in official B. Braun/Aesculap catalogue |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical taper point needle | 37020 (USP 0, 37 mm needle, 1 × 75 cm) | Comparable by category (not interchangeable 1:1) | Material, gauge, colour and length (75 cm) match; 37 mm cylindrical taper point needle, not grooved |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or Laboratorio Aragó are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tender. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the grooved Taperpoint HR25 needle is indicated for soft, vascular and poorly distensible flat tissues that require non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar or triangular point profiles from the same PREMISUT Prime range.
- Needle size: the 25 mm HR is ideal for superficial and medium-thickness fields. If you need greater reach, the HR30 (ref. AMP732HR3010) or HR35 (ref. AMP732HR3510) are available in USP 0 and 75 cm; for microsurgery, the same family offers 10–13 mm needles in fine gauges.
- Gauge: USP 0 (metric 3.5) offers a very balanced medium-high tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR25 Prime needle is available in 4/0 (AMP732HR2540) and 5/0 (AMP732HR2550); for greater strength, USP 1 (AMP732HR2501.2) with the same profile.
- Presentation: if you prefer to make the most of each opening with two armed ends, choose the double-thread version 2 × 75 cm (AMP732HR2510.2); as an economical alternative, the standard-quality PREMISUT (AM732HR2510) retains the needle, gauge and colour.
- Prime range: the PREMISUT Prime line retains the geometry of the standard version with an improved needle finish (superior penetration); useful when the protocol requires premium quality in delicate tissues.
- Pre-use verification: always confirm the full reference (HR25 needle, USP 0 gauge and 75 cm length) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable. Store below 30 °C, protected from moisture and direct sunlight.