Description
1. Commercial Introduction
The polypropylene suture PREMISUT Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable suture with predictable behaviour, maximum tensile strength and minimal tissue reaction is needed. This presentation incorporates double needle ½ circle with Taperpoint conical point of 20 mm (profile 2×HR20), gauge USP 5/0 and blue thread of 90 cm: a high-precision configuration, especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of delicate soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability, which facilitates hospital stock management and presentation to public tenders. It is marketed under the factory reference P733HR2050-2 (SKU Cahnos AMP733HR2050-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence nor the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle of ½ circle with cylindrical body and Taperpoint conical point penetrates soft and friable tissues separating the fibres without cutting them, minimising trauma to the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The HR20 profile of 20 mm offers excellent control in superficial and medium-thickness surgical fields. The double needle format (2×) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. The Prime quality adds a premium needle finish with improved penetration compared to the standard PREMISUT quality. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / line | PREMISUT Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament of a single filament, without coating or braiding |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.10 – 0.149 mm (indicative according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 20 mm (2×HR20, double needle) |
| Manufacturing quality | Prime (premium finish, improved penetration) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P733HR2050-2 |
| Reference Cahnos (SKU) | AMP733HR2050-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 5/0 | 1 | 0.10 – 0.149 mm |
3.3. Family PREMISUT 2×HR20 Prime (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
| 2×HR20 Prime (product analysed) | 90 cm, USP 5/0, blue | P733HR2050-2 / AMP733HR2050-2 |
| 2×HR20 Prime | 90 cm, USP 4/0 | P733HR2040-2 / AMP733HR2040-2 |
| 2×HR20 Prime | 90 cm, USP 3/0 | P733HR2030-2 / AMP733HR2030-2 |
| 2×HR20 Prime | 90 cm, USP 2/0 | P733HR2020-2 / AMP733HR2020-2 |
| 2×HR20 Prime VisiBlack | 90 cm, USP 5/0, black needle | P733HR2050-2VB / AMP733HR2050-2VB |
| 2×HR25 Prime VisiBlack | 90 cm, USP 5/0, black needle | P733HR2550-2VB / AMP733HR2550-2VB |
4. Equivalences and Cross-References
The reference P733HR2050-2 corresponds to the official nomenclature of the PREMISUT Prime range (profile 2×HR20, double needle with conical point of 20 mm, USP 5/0 gauge and blue thread of 90 cm) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (PREMISUT Prime) | 1/2 circle conical 2×HR20, USP 5/0, blue, 90 cm (standard needle) | P733HR2050-2 / AMP733HR2050-2 | Source reference (current product) | Analysed product; factory reference without altering characters |
| Cahnos (PREMISUT Prime VisiBlack) | 1/2 circle conical 2×HR20, USP 5/0, blue, 90 cm (black needle) | P733HR2050-2VB / AMP733HR2050-2VB | Direct range equivalent | Same material, gauge, HR20 needle and length; only the VisiBlack finish varies (high-visibility black needle) |
| Cahnos (PREMISUT Prime VisiBlack) | 1/2 circle conical 2×HR25, USP 5/0, blue, 90 cm (black needle) | P733HR2550-2VB / AMP733HR2550-2VB | Configuration equivalent (same system) | Same material, gauge, colour and length; HR25 needle of 25 mm versus HR20 of 20 mm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, 90 cm, double RB-1 taperpoint needle of 17 mm | 8556G (2×RB-1, box of 12 units) / 8556H (box of 36 units) | Comparable by category (not interchangeable 1:1) – code confirmed | Material, gauge, colour, length and double conical-point needle match; the RB-1 needle of 17 mm differs from HR20 of 20 mm. Verified in Ethicon catalogue and authorised distribution |
| Ethicon (J&J MedTech) | PROLENE® with VISI-BLACK® needle – 5/0, 90 cm, double RB-1 needle of 17 mm (black needle) | 8356H | Comparable by category (not interchangeable 1:1) – code confirmed | High-visibility black needle of 17 mm versus HR20 of 20 mm; same blue polypropylene base. Verified in the Ethicon product centre |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 (EP 1), 90 cm, double needle 2×HR26 | C2090905 | Comparable by category (not interchangeable 1:1) – code confirmed | Same material, gauge, colour and double conical needle; HR26 needle of 26 mm versus HR20 of 20 mm; RacePack packaging. Verified in B. Braun catalogue and GUDID/FDA |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, 5/0 (EP 1), 90 cm, double needle 2×HR26 CV RCP | CVC3090905 | Comparable by category (not interchangeable 1:1) – code confirmed | The material differs (copolymer of polypropylene and polyethylene versus pure polypropylene) and the 26 mm needle. Verified in official B. Braun catalogue |
| Medtronic (Covidien) / Serag-Wiessner / DemeTECH | Surgipro™ II / SERAPREN® / DemeLENE™ – blue polypropylene | Consult official catalogue for 5/0, 90 cm, 2×HR20 | Pending confirmation | Sector families with similar clinical indication; confirm material (copolymer versus pure polypropylene), geometry and needle size in official data sheet before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P733HR2050-2 with other brands; comparisons with PROLENE®, Premilene®, Optilene® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to be sutured: the Taperpoint conical-point needle with cylindrical body is the choice for soft, friable and thin-walled vascular tissues, as it separates the fibres without cutting them (optimal in cardiovascular surgery, ophthalmology and neurosurgery). If the protocol requires passing through more fibrous tissue or calcified adventitia, consider the trocar-point (Tapercut) variant from the same range.
Gauge: USP 5/0 (metric 1) is very fine and highly manageable, ideal for microsurgery, ophthalmology, microvascular surgery and delicate soft tissue. The same 2×HR20 Prime needle is available in 4/0 (ref. AMP733HR2040-2), 3/0 (ref. AMP733HR2030-2) and 2/0 (ref. AMP733HR2020-2) for greater strength depending on the tissue plane to be sutured.
Needle size: the 20 mm HR offers excellent control in superficial and medium-thickness surgical fields. For smaller or paediatric fields, the HR16 is available and, for deeper planes, the HR25 from the same Prime family in 5/0 (ref. AMP733HR2550-2VB).
Double-needle format and Prime range: the 2×HR20 presentation allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. Prime quality offers a superior needle finish with improved penetration compared with standard PREMISUT quality; if needle visibility is critical, choose the VisiBlack black-needle variant (ref. AMP733HR2050-2VB).
Verification and storage: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HR2050-2 and the batch number for traceability in the operating theatre. Store below 30 °C, protected from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.