We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) PREMISUT | ⅜ Circle Needle Reverse Cutting Triangular Point DS 24 mm | USP 2/0 Gauge (Metric 3) | Violet Grooved Thread 75 cm | Ref. 1L12DS2420 | Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable suture PREMISUT of Polyglactin 910 (PGLA) in standard quality: violet braided grooved multifilament thread, USP 2/0 (metric 3) gauge and 75 cm length, mounted with a ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24). Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. 1L12DS2420, presentation in a box of 12 units with a minimum order of 30 boxes for institutional B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L12DS2420

Description

1. Commercial Introduction

The multifilament absorbable suture PREMISUT Polyglactin 910 (PGLA), reference 1L12DS2420, is the trusted solution for professionals seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security in tissue approximation, ligatures and ophthalmic surgery. Its ⅜ circle needle with a 24 mm reverse cutting triangular point (DS 24) ensures firm, controlled penetration in tissues of a certain consistency, while the 75 cm violet braided and grooved thread offers optimal visibility over the surgical field and smooth sliding during suturing.

It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and distributors of surgical material. Commercial presentation in a box of 12 units with a minimum order of 30 boxes, designed for institutional stock management.

2. Technical explanation of the product and procedure

Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in medium gauges such as USP 2/0 (metric 3).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity, maintaining the necessary tensile strength during the first weeks of healing while the tissue recovers its own resistance. The ⅜ circle needle with a 24 mm reverse cutting triangular point (inverted triangle) penetrates firm, non-compliant tissues with controlled trauma, avoiding tearing, making it especially suitable for skin, fascia, aponeurosis and sclera. The violet colour improves thread visibility over the surgical field. The product is supplied sterile by ethylene oxide, is single-use and is not resterilisable.

3. Technical Specifications

3.1. Technical data sheet for reference 1L12DS2420

Parameter Specification
Brand / Range PREMISUT (standard quality)
Reference (SKU) 1L12DS2420
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 2/0 (metric 3)
Thread colour Violet (also available undyed in the range)
Thread length 75 cm
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS 24 (24 mm)
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75% of initial strength
3 weeks 50% of initial strength
4 weeks 30 % of the initial strength
Complete absorption 56 – 72 days (hydrolysis)

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.349 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 (PGLA) is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of braided polyglactin 910:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided coated polyglactin 910, violet or colourless)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ⅜ circle needles (DS series, brand PREMISUT)

Within the Cahnos catalogue, its direct equivalent in the same configuration (DS 24 mm triangular needle, USP 2/0 gauge, 75 cm thread) in undyed colour is reference 1L22DS2420, and in the higher range (Prime quality) references P1L12DS2420 (violet) and P1L22DS2420 (undyed). If a longer absorption profile is preferred (60-90 days), in the polyglycolic acid (PGA) family reference AM112DS2420 stands out, with the same DS 24 mm needle geometry. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 (metric 3) gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures and ophthalmic surgery. The reverse cutting triangular point needle (DS 24) is especially recommended in firm, non-compliant tissues, where the needle passage must be clean and without tearing.

Reference Variant
1L12DS2420 Standard PGLA USP 2/0, ⅜ triangular needle DS 24 mm, violet, 75 cm (current product)
1L22DS2420 Standard PGLA USP 2/0, same DS 24 mm needle, undyed colour
1L12DS2430 Standard PGLA USP 3/0, DS 24 mm needle, violet, 75 cm (finer gauge)
1L12DS2410 PGLA standard USP 0, needle DS 24 mm, violet, 75 cm (larger gauge)
1L12DS2620 Standard PGLA USP 2/0, DS 26 mm needle, violet, 75 cm (larger needle)
1L18DS2440 Standard PGLA USP 4/0, DS 24 mm needle, violet, 70 cm (fine tissues)
AM112DS2420 PGA USP 2/0, DS 24 mm needle, violet, 75 cm (absorption from 60 to 90 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. As it is a sterile single-use product, always check the integrity of the packaging before each procedure and respect the expiry date. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.

Additional information

Brand

PREMISUT

Material

Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide

Gauge

USP 2/0 (metric 3)

Thread diameter

0.30 – 0.349 mm

Absorption mechanism

By hydrolysis, between 56 and 72 days

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Reference

1L12DS2420

Brand / Range

PREMISUT (standard quality)

Thread structure

Braided multifilament with grooved finish

Tip type

Triangular with reverse cutting (inverted triangular)

Needle size

DS 24 (24 mm)

Medida de aguja

DS 24

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) PREMISUT | ⅜ Circle Needle Reverse Cutting Triangular Point DS 24 mm | USP 2/0 Gauge (Metric 3) | Violet Grooved Thread 75 cm | Ref. 1L12DS2420 | Box of 12 units”

Your email address will not be published. Required fields are marked *