Description
1. Commercial Introduction
The absorbable suture PREMISUT Prime Polyglactin 910 (PGLA), reference P1L22DS1650, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing groups and healthcare distributors. It combines a synthetic copolymer with predictable clinical behaviour, exceptional handling and great knot security in tissue approximation, ligatures and ophthalmic surgery.
Its ⅜ circle needle with a 16 mm reverse cutting triangular point ensures firm, controlled penetration even in non-compliant tissues, while the braided, coated thread in colourless offers total aesthetic discretion on the surgical field, smooth glide and reliable knot tying. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for the continuous supply of your healthcare facility.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a coated (finished) surface. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling and firm, secure knotting, even in fine gauges such as USP 5/0 (metric 1).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ⅜ circle needle with reverse cutting triangular point penetrates firm, fibrous tissues with controlled trauma, avoiding tears; it is therefore especially indicated in ophthalmic surgery (sclera), skin and mucous membranes. The colourless colour guarantees optimal aesthetic integration. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L22DS1650
| Parameter | Specification |
| Brand / Range | PREMISUT (Prime quality, premium range) |
| Reference (SKU) | P1L22DS1650 |
| Material | Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 5/0 (metric 1) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | 3/8 circle |
| Tip type | Triangular with reverse cutting (inverted triangular, reverse cutting) |
| Needle size | DS16 (16 mm) Prime |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56 – 72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days, with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Polyglactin 910 is the most widely used medium-duration absorbable multifilament on the surgical market. This PREMISUT Prime suture is equivalent in composition and clinical behaviour to the main commercial ranges of polyglactin 910, maintaining the same absorption profile (56–72 days) and tensile strength retention:
| Manufacturer / commercial house | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Range of polyglactin 910 with 3/8 circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent with the same configuration (DS16 mm triangular needle, USP 5/0 gauge and 75 cm) in violet is reference P1L12DS1650; the standard version (non-Prime quality) of this same presentation in colourless corresponds to reference 1L22DS1650. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue and the necessary gauge according to the anatomical area. USP 5/0 (metric 1) gauge is indicated for delicate tissues: thin skin, mucous membranes, subcutaneous tissue and ophthalmic surgery. The reverse cutting triangular point needle is recommended when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis, sclera).
| Reference | Variant |
| P1L22DS1650 | PGLA Prime, DS16 mm needle, USP 5/0, colourless, 1 × 75 cm (current product) |
| P1L12DS1650 | PGLA Prime, DS16 mm needle, USP 5/0, violet, 1 × 75 cm (maximum visibility in the field) |
| 1L22DS1650 | PGLA standard, DS16 mm needle, USP 5/0, colourless, 1 × 75 cm |
| P1L11DS1650 | PGLA Prime, DS16 mm needle, USP 5/0, violet, 1 × 45 cm (reduced length) |
| P1L22DS1640 | PGLA Prime, DS16 mm needle, USP 4/0, colourless, 1 × 75 cm (larger gauge) |
| P1L21XHS1650 | PGLA Prime, ½ circle XHS16 needle, USP 5/0, colourless, 1 × 45 cm (precision cutting) |
| AMP122DS1650 | PGA, DS16 mm needle, USP 5/0, colourless (absorption 60 to 90 days) |
| AMP2L22DS1650 | PGLAR (Polyglactin 910 Rapid), DS16 mm needle, USP 5/0, colourless (absorption 40 to 45 days) |
The colourless colour is especially valued in aesthetic and reconstructive surgery procedures for its discretion. All references are supplied in a box of 12 units. As this is sterile single-use material, check the integrity of the packaging before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or consultation of additional gauges, lengths and colours on request, contact our technical-commercial team at Cahnos.





Reviews
There are no reviews yet.