Description
The Absorbable Multifilament PGLA Polyglactin 910 Suture Ref. 1L12DS2620, from the PREMISUT range in standard quality, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security. Its ⅜ circle needle with reverse cutting triangular point of 26 mm (DS26) allows firm and controlled penetration in consistent tissues, especially indicated in ophthalmic surgery, ligatures and tissue approximation.
Available in B2B presentation in boxes of 12 units, this reference offers excellent value for money for hospitals, ophthalmic clinics, purchasing centres and distributors of surgical material. Sterile medical device, single-use and non-resterilisable.
Technical explanation
It is a braided (multifilament) absorbable synthetic suture made of polyglactin 910 (PGLA), a copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration facilitates the passage of the thread through tissue, offers smooth sliding and guarantees firm and secure knot tying, even in fine diameter calibres such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ⅜ circle needle with reverse cutting triangular point (inverted triangular / reverse cutting) of 26 mm penetrates firm and dense tissues with controlled trauma, avoiding tears. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide, is single-use and does not allow resterilisation.
Technical specifications
| Parameter | Specification |
|---|---|
| Brand / Range | PREMISUT (standard quality) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3, approximate diameter 0.30 – 0.349 mm according to Pharmacopoeia) |
| Thread colour | Violet (also available colourless in the range) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting (inverted triangular / reverse cutting) |
| Needle size | DS26 (26 mm) |
| Absorption mechanism | By hydrolysis, between 56 and 72 days |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Reference (SKU) | 1L12DS2620 |
Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 30 % of the initial strength |
| Complete absorption | 56 – 72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable and controlled absorption rate. Price per box of 12 units.
Equivalences and cross-references
Polyglactin 910 (PGLA) is the most widely used medium-duration multifilament absorbable in the surgical market. This PREMISUT suture is equivalent in composition, absorption profile and mechanical behaviour to the main commercial ranges of polyglactin 910:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Range of polyglactin 910 with ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (triangular needle DS 26 mm, USP 2/0 calibre, violet thread 75 cm) in the higher range is reference P1L12DS2620 (Prime quality). It shares the family with the other calibres of the DS26 series: 1L12DS2630 (USP 3/0) and P1L12DS2630 (Prime USP 3/0). The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.
Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the necessary calibre according to the anatomical area. The USP 2/0 (metric 3) calibre offers an ideal balance between initial strength and manageability for fine tissues, ligatures and ophthalmic surgery. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing (skin, fascia, aponeurosis, sclera).
| Reference | Variant |
|---|---|
| 1L12DS2620 | Standard PGLA USP 2/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (current product) |
| P1L12DS2620 | Prime PGLA USP 2/0, same configuration DS 26 mm, violet, 75 cm (higher range) |
| 1L12DS2630 | Standard PGLA USP 3/0, ⅜ triangular needle DS 26 mm, violet, 75 cm (smaller calibre) |
| P1L12DS2630 | Prime PGLA USP 3/0, ⅜ triangular needle DS 26 mm, violet, 75 cm |
| 1L12DS2420 | Standard PGLA USP 2/0, ⅜ triangular needle DS 24 mm, violet, 75 cm (shorter needle) |
| AM112DS2620 | PGA USP 2/0, DS 26 mm needle, violet, 75 cm (absorption 60 to 90 days) |
All references are supplied in boxes of 12 units; consult special B2B conditions and volume orders with our technical-commercial team at Cahnos. As it is a sterile single-use product, always check the integrity of the packaging before each procedure and respect the expiry date.





Reviews