Description
1. Product Presentation
Prime absorbable Poliglactin 910 (PGLA) suture is the professional choice for surgeons, operating theatre services and purchasing centres seeking a high-performance synthetic multifilament thread with exceptional handling and fully predictable absorption. Its ⅜ circle reverse cutting triangular needle (DS36) and USP 1 gauge make it a reliable solution for approximating firm tissues, ligatures and ophthalmic surgery, with a highly competitive quality-price ratio for B2B supply to hospitals, ophthalmic clinics, purchasing centres and distributors.
2. Technical explanation
Poliglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration facilitates the passage of the thread through tissue, offers smooth sliding and guarantees excellent knot security, even in larger diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. The ⅜ circle needle with 36 mm reverse cutting triangular point penetrates firm and dense tissues with controlled trauma, avoiding tears, and is especially indicated for tissue approximation, ligatures and ophthalmic and general surgery procedures.
The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised. The violet colour improves thread visibility on the surgical field.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Brand | PREMISUT (Prime range) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime |
| Gauge | USP 1 (metric 4) |
| Colour | Violet (also available undyed) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle |
| Tip type | Triangular with reverse cutting |
| Needle size | DS 36 mm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L12DS3601 |
Tensile strength retention profile after implantation
| Time point | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
Poliglactin 910 (PGLA) is the most widely used medium-duration absorbable multifilament on the market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of poliglactin 910:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Poliglactina 910 range, ⅜ circle needles (DS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the poliglactin 910 family is reference 1L12DS3601 (same DS 36 mm configuration, USP 1, violet, 75 cm), ideal when looking for a standard quality alternative to the superior Prime quality of this reference. In the polyglycolic acid (PGA) family, AMP112DS3601 stands out (same DS 36 mm triangular needle, USP 1, violet, 75 cm), recommended when a 60 to 90 day absorption profile is preferred.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes and high-tension closures. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing.
| Reference | Variant |
|---|---|
| P1L12DS3610 | PGLA Prime USP 0, ⅜ triangular DS 36 mm needle, violet, 75 cm (smaller gauge, moderate tension) |
| P1L12DS3602 | PGLA Prime USP 2, ⅜ triangular DS 36 mm needle, violet, 75 cm (larger gauge) |
| P1L12DS3010 | PGLA Prime USP 0, ⅜ triangular needle DS 30 mm, violet, 75 cm (shorter needle) |
| P1L12DS4001 | PGLA Prime USP 1, ⅜ triangular DS 40 mm needle, violet, 75 cm (longer needle) |
| P1L12RDS3601.2 | PGLA Prime USP 1, ⅜ triangular DS 36 mm needle, double thread 2 x 75 cm (greater yield per pack) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews