We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Poliglactin 910 Prime Suture | 3/8 Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) | USP 1 Gauge (Metric 4) | Violet Thread 75 cm | Ref. P1L12DS3601 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Prime absorbable Poliglactin 910 (PGLA) suture, violet fluted braided multifilament, with ⅜ circle reverse cutting triangular point needle of 36 mm (DS36) and USP 1 gauge (metric 4). 75 cm thread with predictable hydrolysis absorption in 56-72 days and strength retention of 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks. Product sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Ideal for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L12DS3601, presentation in box of 12 units.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L12DS3601

Description

1. Product Presentation

Prime absorbable Poliglactin 910 (PGLA) suture is the professional choice for surgeons, operating theatre services and purchasing centres seeking a high-performance synthetic multifilament thread with exceptional handling and fully predictable absorption. Its ⅜ circle reverse cutting triangular needle (DS36) and USP 1 gauge make it a reliable solution for approximating firm tissues, ligatures and ophthalmic surgery, with a highly competitive quality-price ratio for B2B supply to hospitals, ophthalmic clinics, purchasing centres and distributors.

2. Technical explanation

Poliglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration facilitates the passage of the thread through tissue, offers smooth sliding and guarantees excellent knot security, even in larger diameter gauges such as USP 1.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. The ⅜ circle needle with 36 mm reverse cutting triangular point penetrates firm and dense tissues with controlled trauma, avoiding tears, and is especially indicated for tissue approximation, ligatures and ophthalmic and general surgery procedures.

The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised. The violet colour improves thread visibility on the surgical field.

3. Technical Specifications

Parameter Value
Brand PREMISUT (Prime range)
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Quality Prime
Gauge USP 1 (metric 4)
Colour Violet (also available undyed)
Thread length 75 cm
Needle shape ⅜ circle
Tip type Triangular with reverse cutting
Needle size DS 36 mm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L12DS3601

Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Poliglactin 910 (PGLA) is the most widely used medium-duration absorbable multifilament on the market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of poliglactin 910:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
Laboratory Aragó Poliglactina 910 range, ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent in structure and needle within the poliglactin 910 family is reference 1L12DS3601 (same DS 36 mm configuration, USP 1, violet, 75 cm), ideal when looking for a standard quality alternative to the superior Prime quality of this reference. In the polyglycolic acid (PGA) family, AMP112DS3601 stands out (same DS 36 mm triangular needle, USP 1, violet, 75 cm), recommended when a 60 to 90 day absorption profile is preferred.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue and the gauge needed according to the anatomical area. USP 1 gauge (metric 4) is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes and high-tension closures. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing.

Reference Variant
P1L12DS3610 PGLA Prime USP 0, ⅜ triangular DS 36 mm needle, violet, 75 cm (smaller gauge, moderate tension)
P1L12DS3602 PGLA Prime USP 2, ⅜ triangular DS 36 mm needle, violet, 75 cm (larger gauge)
P1L12DS3010 PGLA Prime USP 0, ⅜ triangular needle DS 30 mm, violet, 75 cm (shorter needle)
P1L12DS4001 PGLA Prime USP 1, ⅜ triangular DS 40 mm needle, violet, 75 cm (longer needle)
P1L12RDS3601.2 PGLA Prime USP 1, ⅜ triangular DS 36 mm needle, double thread 2 x 75 cm (greater yield per pack)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Brand

PREMISUT (Prime range)

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Structure

Multifilament braided fluted

Gauge

USP 1 (metric 4)

Colour

Violet (colourless on request)

Needle type

Reverse cutting triangular point

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 36

Usp

1

Color

Colourless, Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Poliglactin 910 Prime Suture | 3/8 Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) | USP 1 Gauge (Metric 4) | Violet Thread 75 cm | Ref. P1L12DS3601 – Box of 12 units”

Your email address will not be published. Required fields are marked *