Description
1. Product Presentation
The absorbable multifilament PGLA (Polyglactin 910) Prime VisiBlack suture from the Premisut line is the professional reference solution for the surgeon who demands secure closure, reliable knotting and fully predictable reabsorption. This reference (P1L18HR2220VB) incorporates a ½ circle cylindrical needle with conical point (taperpoint) of 22 mm in high-visibility VisiBlack finish, USP size 2/0 (metric 3) and violet thread of 70 cm.
It is supplied in a box of 12 units, with a minimum order of 30 boxes, and is indicated for tissue approximation, ligatures and ophthalmic surgery. It is a synthetic absorbable medical device, sterile and single-use, with an excellent price-quality ratio for B2B procurement of operating theatres, ophthalmic clinics and purchasing centres.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure without grooves. This configuration provides a regular surface that favours the sliding of the thread through the tissue, smooth handling and firm, secure knot tying, even in fine sizes such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. The retention profile maintains the necessary tensile strength during the first weeks of healing: 75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks, the precise time for the tissue to recover its own resistance.
The ½ circle needle with cylindrical body and conical point (taperpoint geometry) with VisiBlack finish combines an atraumatic point with maximum visibility on the surgical field, allowing it to pass through soft tissues of moderate density by separating the fibres without cutting effect and with the least possible tissue tearing. It is the usual configuration in ophthalmic surgery and in the approximation of delicate tissues. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P1L18HR2220VB
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Non-grooved braided multifilament |
| Quality | Prime (Premisut range) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Tip type | Taperpoint |
| Needle size | 22 mm (HR 22) with VisiBlack finish |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HR2220VB |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
3.3. Needle configuration
| Configuration | Value |
|---|---|
| Needle shape | ½ circle |
| Body | Cylindrical |
| Tip | Taperpoint |
| Needle size | 22 mm (HR 22) |
| Needle type | HR 22 VisiBlack Prime |
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
Within the Cahnos catalogue, its standard quality equivalent with the same HR 22 mm needle configuration, size 2/0 and 70 cm strand (without VisiBlack finish) corresponds to the 1L18HR22 series, and the versions with colourless thread and VisiBlack needle are identified as P1L28HR2220VB. The indicated equivalences are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary size according to the anatomical area. USP size 2/0 (metric 3) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The 22 mm ½ circle conical point needle is especially recommended in delicate tissues where the least possible trauma is sought, such as ophthalmic surgery, and its VisiBlack finish improves the contrast of the needle on dark or bloody tissues.
Variants of interest in the Cahnos catalogue:
- P1L18HR2230VB: same HR 22 mm VisiBlack needle, USP size 3/0, violet, 70 cm (finer size for greater precision).
- P1L18HR2240VB: same HR 22 mm VisiBlack needle, USP size 4/0, violet, 70 cm (maximum fineness).
- P1L18HR2620VB: VisiBlack HR 26 mm needle, size 2/0, violet, 70 cm (larger needle radius for wider access).
- P1L18HRT2620: Prime version with trocar point (tapercut) HRT 26 mm, size 2/0, violet, 70 cm (slightly cutting point for tissues of greater density).
- P1L28HR2220VB: same configuration with colourless thread, for applications where minimal visibility of the strand is preferred.
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare centre. Keep the original packaging in a dry, cool place, respect the expiry date and handle the strand with gloves to avoid altering its mechanical properties. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.