Description
1. Commercial Introduction
At Cahnos we offer you the absorbable multifilament Poliglactin 910 (PGLA) suture from the Prime range, reference P1L12HR2220, the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, ambulatory surgery units and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with cylindrical body and conical point (taperpoint) of 22 mm guarantees atraumatic penetration, while the 75 cm violet fluted thread offers optimal visibility over the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio.
2. Technical Explanation
Poliglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling, low memory and firm, secure knot tying, even in fine calibres such as USP 2/0.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (taperpoint) penetrates tissues by separating the fibres without a cutting effect, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery and in the approximation of soft tissues. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P1L12HR2220
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L12HR2220 |
| Brand / Quality | Premisut – Prime |
| Composition | Copolymer of 90% glycolide and 10% L-lactide (Poliglactin 910) |
| Thread structure | Braided multifilament with grooved finish |
| USP / metric gauge | 2/0 (metric 3) |
| Thread colour | Violet (also available colourless in the family) |
| Needle shape | ½ circle, cylindrical body |
| Needle tip | Conical (taperpoint), atraumatic |
| Needle size | 22 mm (HR 22 Prime) |
| Thread length | 75 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (minimum order of 30 boxes) |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units; minimum order of 30 boxes.
4. Equivalences and Cross-References
Poliglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This Prime reference is clinically equivalent, in chemical composition, absorption profile (56-72 days) and tensile strength retention, to the main international lines:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut Sutures | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
| Laboratory Aragó | Premisut range of polyglactin 910 with ½ circle needles |
Within the Cahnos catalogue, its closest references by HR 22 mm needle configuration and 2/0 calibre are the colourless version P1L28HR2220 (70 cm), the violet version P1L18HR2220 (70 cm) and the high-visibility needle version P1L18HR2220VB. As a structural alternative in polyglycolic acid (PGA), with absorption of 60 to 90 days, we have reference AMP112HR2220. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the calibre needed according to the anatomical area. USP 2/0 (metric 3) calibre is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, being widely used in ophthalmic surgery. The 22 mm ½ circle conical point needle is the most atraumatic option for delicate tissues; if you need greater penetration in firm tissues, consider reverse cutting points.
| Reference | Variant of interest |
|---|---|
| P1L12HR2020 | PGLA Prime, HR 20 mm, USP 2/0, violet, 75 cm (shorter needle for very delicate tissues) |
| P1L12HR2230 | PGLA Prime, HR 22 mm, USP 3/0, violet, 75 cm (finer calibre) |
| P1L12HR2240 | PGLA Prime, HR 22 mm, USP 4/0, violet, 75 cm (maximum fineness) |
| P1L12HR2620 | PGLA Prime, HR 26 mm, USP 2/0, violet, 75 cm (larger needle radius) |
| P1L12HR2620.2 | PGLA Prime, HR 26 mm, USP 2/0, violet, 2×75 cm (double thread format) |
| P1L18HS2220 | PGLA Prime, reverse cutting triangular needle HS 22 mm, USP 2/0, violet, 70 cm (greater penetration in firm tissues) |
| AMP112HR2220 | PGA alternative, HR 22 mm, USP 2/0, violet, 75 cm (absorption 60-90 days) |
If you need a longer retention profile (180-210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews