We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 | Needle ½ Circle Cylindrical Body Conical Point HR 40 mm | USP Size 0 (Metric 3.5) | Violet Thread 90 cm | Ref. 1L13HR4010 – Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Synthetic absorbable multifilament polyglactin 910 (PGLA) suture from the Premisut range, with a half-circle needle with cylindrical body and conical point of 40 mm (HR 40), USP 0 gauge (metric 3.5) and violet thread of 90 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference 1L13HR4010, in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L13HR4010

Description

1. Commercial Introduction

The absorbable multifilament polyglactin 910 (PGLA) suture, reference 1L13HR4010 from the Premisut range, is the reference surgical closure solution for professionals who demand a flexible, strong thread with a fully predictable absorption profile in the operating theatre. Its half-circle needle with a cylindrical body and conical point of 40 mm (HR 40) passes through soft tissues by separating the fibres without cutting them, minimising trauma and making it particularly suitable for tissue approximation, ligatures and ophthalmic surgery.

It is a synthetic absorbable medical device, sterile and single-use, with an excellent value for money for B2B procurement in hospitals, ophthalmic clinics, private operating theatres and purchasing groups. It is supplied in a box of 12 units with a minimum order of 30 boxes, ensuring continuous and traceable supply for your healthcare facility.

2. Technical Explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, comfortable glide and firm, secure knot tying, with high initial tensile strength.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The half-circle needle with conical point (Taperpoint) penetrates by separating the fibres without cutting them, and the violet colouration of the thread ensures optimal visibility on the surgical field. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference 1L13HR4010

Characteristic Specification
Reference (SKU) 1L13HR4010
Range / Quality Premisut – Normal quality
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 0 (metric 3.5)
Thread colour Violet (also available colourless)
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Taperpoint conical
Needle size HR 40 mm
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Total absorption 56-72 days (by hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Presentation and ordering conditions

Value Value
Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widely used synthetic absorbable materials on the European market. This reference is clinically comparable, in terms of composition, absorption profile and tensile retention, to the braided multifilament sutures of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Absorbable braided polyglactin 910 range
Laboratory Aragó Polyglactin 910 range with ½ circle needles (TC / HR series)
Assut Assucryl 910 (polyglactin 910)

Within the Cahnos catalogue, its direct equivalent in structure and geometry within the Prime range is reference P1L13HR4010 (same HR 40 mm needle, USP 0, violet thread of 90 cm), ideal when a superior range is sought; in a length of 70 cm, reference 1L18HR4010 is available. The equivalences indicated are for guidance only; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during a healing period of 2 to 4 weeks. The conical point (HR) separates the fibres without cutting them and is ideal for soft and friable tissues; if the tissue is very delicate, the most atraumatic option is the blunt point (HRN), while for firm and dense tissues, the reverse cutting triangular point (HS) or the trocar point (HRT) is recommended.

Reference Variant
1L13HR4010 PGLA USP 0, HR 40 mm conical point needle, violet, 90 cm (current product)
1L13HR4001 PGLA USP 1, same HR 40 mm needle, violet, 90 cm (larger gauge)
1L13HR4002 PGLA USP 2, same HR 40 mm needle, violet, 90 cm (maximum strength)
1L13HR4810 PGLA USP 0, HR 48 mm needle, violet, 90 cm (longer needle)
1L18HR4010 PGLA USP 0, HR 40 mm needle, violet, 70 cm (shorter thread length)
1L13HRT4010 PGLA USP 0, HRT 40 mm trocar point, violet, 90 cm (denser tissues)
AM113HR4010 PGA USP 0, HR 40 mm needle, violet, 90 cm (absorption of 60 to 90 days)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial brands, contact our technical-commercial team.

Additional information

Reference

1L13HR4010

Product line

Premisut – Normal quality

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament with grooved finish

Gauge

USP 0 (metric 3.5)

Thread colour

Violet (also available colourless)

Needle body

Cylindrical

Needle tip

Taperpoint conical

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 40

Usp

0

Color

Colourless, Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 | Needle ½ Circle Cylindrical Body Conical Point HR 40 mm | USP Size 0 (Metric 3.5) | Violet Thread 90 cm | Ref. 1L13HR4010 – Box of 12 units”

Your email address will not be published. Required fields are marked *