Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture in Heavy quality from the Premisut range, reference 1L12HR3010H, is the trusted solution for hospitals, private clinics, ophthalmology operating theatres and purchasing centres seeking a high-performance synthetic absorbable thread with an excellent quality-price ratio. It mounts a ½ circle needle with cylindrical body and conical point of 30 mm (HR 30 Heavy), USP gauge 0 and violet braided thread of 75 cm. Each unit is supplied sterile and ready to use, ideal for tissue approximation, ligatures and ophthalmic surgery, where precision, manageability and fully predictable absorption are required during the first weeks of healing. Request your quotation and immediate availability through the technical-commercial team of Cahnos.
2. Technical explanation of the material and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented as a braided multifilament coated with a grooved finish. This structure confers great flexibility, low memory, smooth sliding and a contained coefficient of friction that favours firm and secure knot tying. Absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 56 to 72 days, with a constant and controlled loss of strength during the critical healing phase, while the tissue recovers its own strength.
The ½ circle needle with cylindrical body and conical point (taperpoint) passes through the tissue separating the fibres without cutting them, which minimises trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, soft tissue approximation and ligatures. The Heavy reinforcement provides a more robust and firm needle body for a more controlled passage in medium-demand tissues. The violet colour guarantees optimal visibility of the thread in the surgical field throughout the procedure. Sterile single-use product, with no possibility of re-sterilisation; check the integrity of the packaging before each use.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L12HR3010H |
| Brand / Quality | Premisut – Heavy |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided and coated multifilament, grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread length | 75 cm |
| Thread colour | Violet (also available colourless) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 30 mm (HR 30 Heavy) |
| Mounting | Needle threaded with suture |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use |
| Presentation | Box of 12 units · Minimum order 30 boxes |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
Absorption and tensile strength retention profile:
| Period | Retention of initial tensile strength |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Total absorption | 56-72 days, by hydrolysis |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures of medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines of the international market:
| Manufacturer / commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, this reference shares a family with the PGLA line of ½ circle cylindrical needle: its direct equivalent in the same HR 30 mm USP 0 configuration corresponds to the standard version without reinforcement (1L12HR3010) and to the Prime (P1L12HR3010) and Prime Heavy (P1L12HR3010H) qualities. The indicated equivalences are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most appropriate suture, assess the wound support time required by the tissue and the gauge according to the anatomical area. USP gauge 0 (metric 3.5) offers an optimal balance between initial strength and manageability for soft tissues, ligatures and fine tissue planes; gauges 2/0 and 3/0 are intended for more delicate tissues and USP gauge 1 for areas subjected to greater traction. The conical point is suitable for soft tissues and delicate structures such as ocular ones; for fibrous tissues or the sclera, trocar-type penetration points are recommended and for maximum atraumaticity, the blunt point.
Variants of interest in the same PGLA family: 1L12HR3010H (Heavy USP 0, the present reference), P1L12HR3010H (Prime Heavy USP 0), P1L12HR3010 (Prime USP 0), 1L12HR3001H (Heavy USP 1), 1L12HR3020 (gauge 2/0), 1L12HR3030 (gauge 3/0), P1L12RHRP3001 (Ultra Plus trocar point for fibrous tissues) and AM112HR3010H (equivalent in PGA). All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to guarantee the continuous supply of your centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or hospital supply contracts, contact the technical-commercial team of Cahnos.