Description
1. Commercial presentation
At Cahnos we offer you the absorbable multifilament Poliglactin 910 (PGLA) suture, reference 1L13HR3620, from the Premisut range. It is the professional choice for surgery services, ophthalmology and procedures that require a secure, manageable closure with controlled absorption. It combines a ½ circle needle with cylindrical body and conical point of 36 mm (HR 36) with a 90 cm violet fluted thread in USP 2/0 gauge, ideal for maximum visibility on the surgical field.
It is presented in B2B format in a box of 12 units, with a minimum order of 30 boxes, ensuring continuous supply for operating theatres, ophthalmology clinics, distributors and purchasing centres for surgical material, with an excellent quality-price ratio.
2. Technical Explanation
Poliglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, formed into a braided multifilament structure with a fluted finish. This configuration provides great flexibility, low shape memory, excellent initial tensile strength and smooth passage through tissue, with firm and secure knot tying even in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, over a period of 56 to 72 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance. The ½ circle cylindrical needle with conical point of 36 mm penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, approximation of soft tissues and ligatures. The violet colour of the thread ensures optimal visibility on the surgical field. Product sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 1L13HR3620
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L13HR3620 |
| Brand / Quality | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet (colourless version available in the family, ref. 1L23HR3620) |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taper point |
| Needle size | 36 mm (HR 36) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm (indicative according to Pharmacopoeia) |
4. Equivalences and Cross-References
Poliglactin 910 is one of the most well-established multifilament synthetic absorbable suture raw materials on the market. This braided, medium-absorption suture is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines of other commercial houses:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| Laboratory Aragó | Poliglactin 910 range with ½ circle cylindrical needles (HR series) |
Within the Cahnos catalogue, its direct equivalent with the same configuration (HR 36 mm needle, USP 2/0 gauge, 90 cm thread) is reference 1L23HR3620 in colourless for greater discretion in the field; the superior Prime quality is processed as P1L13HR3620 (violet) or P1L23HR3620 (colourless). In the polyglycolic acid (PGA, 60-90 day absorption) family, the alternative is AM123HR3620. The indicated equivalences are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 2/0 gauge offers an optimal balance between strength and fineness, indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The ½ circle conical point needle of 36 mm is atraumatic; if you need to penetrate firmer and denser tissues (skin, fascia, sclera), consider the reverse cutting (HS) or trocar (HRT) points available in the same range.
| Reference | Variant |
|---|---|
| 1L13HR3620 | PGLA USP 2/0, HR 36 mm needle, violet, 90 cm (current product) |
| 1L23HR3620 | PGLA USP 2/0, HR 36 mm needle, colourless, 90 cm (discretion in the field) |
| P1L13HR3620 | PGLA Prime USP 2/0, HR 36 mm needle, violet, 90 cm (superior quality) |
| 1L12HR3620 | PGLA USP 2/0, HR 36 mm needle, violet, 75 cm (shorter thread length) |
| 1L28HR3620 | PGLA USP 2/0, HR 36 mm needle, colourless, 70 cm (shorter thread, colourless) |
| 1L13HR3640 | PGLA USP 4/0, HR 36 mm needle, violet, 90 cm (fine gauge, delicate tissues) |
| 1L23HR3610 | PGLA USP 0, HR 36 mm needle, colourless, 90 cm (larger gauge) |
| AM123HR3620 | PGA USP 2/0, HR 36 mm needle (60-90 day absorption) |
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.