We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | ½ Circle Cylindrical Needle Conical Point (Taperpoint) HR 26 mm | USP Gauge 4/0 (Metric 1.5) | Violet Grooved Thread 70 cm | Ref. 1L18HR2640 – Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament suture of polyglactin 910 (PGLA) with a ½ circle cylindrical needle with conical point (taperpoint) of 26 mm, USP gauge 4/0 (metric 1.5) and violet grooved thread of 70 cm. Predictable absorption by hydrolysis in 56-72 days, with retention of tensile strength of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and excellent knot tying safety. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. 1L18HR2640 in box of 12 units; minimum order of 30 boxes for B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L18HR2640

Description

Product presentation

The absorbable multifilament suture of polyglactin 910 (PGLA) from the Premisut line, reference 1L18HR2640, is the ideal technical solution for the professional who demands a secure closure, reliable knotting and totally predictable reabsorption. It incorporates a ½ circle needle with cylindrical body and conical point (taperpoint) of 26 mm, violet grooved thread of 70 cm and USP gauge 4/0 (metric 1.5). It is supplied in a box of 12 units with a minimum order of 30 boxes, and constitutes the reference option for the approximation of soft tissues, ligatures and ophthalmic surgery. Synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B supply of operating theatres, ophthalmic clinics and purchasing centres.

Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer made up of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that favours the sliding of the thread through the tissue, smooth handling and firm, secure knot tying even in fine gauges such as USP 4/0.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and conical point (taperpoint geometry) combines an atraumatic point with clean passage through soft tissues of moderate density, with the least possible tissue tearing; it is the usual configuration in ophthalmic surgery and in the approximation of delicate tissues. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.

Technical specifications

Technical data sheet for reference 1L18HR2640

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Range / quality Normal (Premisut line)
Gauge USP 4/0 (metric 1.5)
Thread colour Violet grooved
Needle shape ½ circle
Needle body Cylindrical
Tip type Taperpoint
Needle size 26 mm (HR 26)
Thread length 70 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) 1L18HR2640

Tensile strength retention profile

Period Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate. Price per box of 12 units.

Needle configuration

Configuration Value
Needle shape ½ circle
Body Cylindrical
Tip Taperpoint
Needle size 26 mm (HR 26)
Needle type HR 26 (Premisut range)

Equivalences and cross-references

This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic (Covidien) Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
DemeTECH Vitacryl (coated braided polyglactin 910)

Within the Cahnos catalogue, its closest equivalent is the higher-range reference P1L18HR2640 (same HR 26 mm needle configuration, gauge 4/0 and 70 cm thread) and the version with high-visibility dark needle P1L18HR2640VB. In the polyglycolic acid (PGA) family, reference AM118HR2640 stands out, with an absorption profile of 60 to 90 days. The equivalences indicated are for guidance; for a formal replacement of references, please consult our technical-commercial department.

Selection tips and variants of interest

To choose the most suitable suture, take into account the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP gauge 4/0 (metric 1.5) is indicated for fine, low-tension tissues: skin, mucosa, subcutaneous tissue and delicate planes where aesthetic healing and minimal trauma are sought. The 26 mm conical point needle is especially recommended for delicate tissues, such as ophthalmic surgery.

  • P1L18HR2640: Prime version with the same HR 26 mm needle, gauge 4/0 and 70 cm thread (higher range).
  • P1L18HR2640VB: same configuration with high-visibility dark needle (VisiBlack).
  • 1L18HR2630: same HR 26 mm needle, USP gauge 3/0 (larger gauge for moderate tension).
  • 1L18HRT2630: PGLA with trocar point (tapercut) HRT 26 mm, USP 3/0 (slightly cutting point for tissues of higher density).
  • 1L18HS2630: PGLA with reverse cutting triangular needle HS 26 mm, USP 3/0 (greater penetration firmness).
  • AM118HR2640: alternative in polyglycolic acid (PGA), absorption of 60 to 90 days.

If you need a longer retention profile (180-210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. Keep the original packaging in a dry, cool place, respect the expiry date and handle the thread with gloves so as not to alter its mechanical properties.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 4/0 (metric 1.5)

Thread colour

Violet grooved

Needle body

Cylindrical

Tip type

Taperpoint

Needle size

26 mm (HR 26)

Absorption

Complete hydrolysis between 56 and 72 days

Tensile strength retention

75 % at 2 weeks, 50 % at 3 weeks, 30 % at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use

Tissue reaction

Minimal

Application

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Quality range

Normal (Premisut line)

Medida de aguja

HR 26

Usp

4/0

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | ½ Circle Cylindrical Needle Conical Point (Taperpoint) HR 26 mm | USP Gauge 4/0 (Metric 1.5) | Violet Grooved Thread 70 cm | Ref. 1L18HR2640 – Box of 12 units”

Your email address will not be published. Required fields are marked *