Description
1. Product Presentation
The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L28HR3630 from the Premisut range by Cahnos, is the trusted technical choice for the professional seeking a synthetic absorbable surgical suture with predictable behaviour, excellent handling and maximum knot security. It combines a ½ circle needle with cylindrical body and conical point of 36 mm (HR 36) with a colourless grooved thread of 70 cm in USP size 3/0 (metric 2), ideal for approximation of soft tissues, ligation and ophthalmic surgery. The colourless thread offers maximum discretion on the surgical field.
It is presented in B2B format in a box of 12 units, with a minimum order of 30 boxes, designed for the continuous supply of operating theatres, ophthalmic clinics, distributors and purchasing centres for surgical material, with excellent value for money.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides great flexibility, low shape memory, excellent initial tensile strength and smooth passage through tissue, with firm and secure knot tying even in fine sizes such as USP 3/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own strength.
The ½ circle needle with cylindrical body and conical point penetrates by separating the fibres without cutting effect, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery and in the approximation of soft tissues. Product sterilised by ethylene oxide, single-use and not suitable for resterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference 1L28HR3630
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L28HR3630 |
| Brand / Quality | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Colourless |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (atraumatic point) |
| Needle size | 36 mm (HR 36) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use) |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot security. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This braided, medium-absorption suture is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910) |
| B. Braun | Safil (braided polyglactin 910) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 |
| DemeTECH | DemeCRYL (polyglactin 910) |
| Laboratory Aragó (Premisut) | Polyglactin 910 range with ½ circle cylindrical needles (HR series) |
Within the Cahnos catalogue, its direct equivalent in the same configuration (HR 36 mm needle, USP size 3/0, 70 cm thread) in superior quality is reference P1L28HR3630 (Prime range), the violet version of the same thread is available as 1L18HR3630 and the alternative in polyglycolic acid (PGA, absorption 60-90 days) is AM128HR3630. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
USP size 3/0 (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, and is widely used in ophthalmic surgery. The ½ circle conical point needle of 36 mm is the most atraumatic option for delicate tissues; if you need greater penetration in firm tissues, consider trocar points or reverse cutting points.
| Reference | Variant |
|---|---|
| 1L28HR3630 | PGLA USP 3/0, HR 36 mm needle, colourless, 70 cm (current product) |
| P1L28HR3630 | PGLA Prime quality USP 3/0, HR 36 mm needle, colourless, 70 cm (superior quality) |
| 1L18HR3630 | PGLA USP 3/0, HR 36 mm needle, violet, 70 cm (greater visibility) |
| 1L23HR3630 | PGLA USP 3/0, HR 36 mm needle, colourless, 90 cm (greater thread length) |
| 1L13HR3630 | PGLA USP 3/0, HR 36 mm needle, violet, 90 cm |
| 1L28HR3620 | PGLA USP 2/0, HR 36 mm needle, colourless, 70 cm (smaller size) |
| 1L28HR3601 | PGLA USP 1, HR 36 mm needle, colourless, 70 cm (larger size) |
| 1L28HR2630 | PGLA USP 3/0, HR 26 mm needle, colourless, 70 cm (smaller needle) |
| 1L18HS3630 | PGLA USP 3/0, triangular reverse cutting needle HS 36 mm, violet (firm tissues) |
| AM128HR3630 | PGA USP 3/0, HR 36 mm needle, colourless, 70 cm (absorption 60-90 days) |
All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure the continuous supply of your healthcare facility. If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.