Description
The absorbable multifilament Polyglactin 910 (PGLA) suture, reference 1L13HR2620 from the Premisut range, is the trusted choice for the professional seeking a synthetic absorbable thread with predictable behaviour, excellent handling and maximum knot security. Its half-circle needle with cylindrical body and taper point (taperpoint) of 26 mm (HR 26) allows clean and atraumatic penetration, particularly suitable for the approximation of soft tissues, ligatures and ophthalmic surgery. Available in B2B presentation in boxes of 12 units with a minimum order of 30 boxes, this reference offers excellent value for money for hospitals, clinics, ophthalmology operating theatres, distributors and purchasing centres for surgical supplies, with sterile, traceable and ready-to-use supply.
Polyglactin 910 is a biocompatible synthetic copolymer composed of 90% glycolide and 10% L-lactide, presented as a braided multifilament coated with a grooved finish. This structure confers great flexibility, low shape memory, smooth passage through tissue and a low coefficient of friction that favours firm and secure knot seating, even in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile maintains wound edge apposition during the critical healing phase (2 to 4 weeks), while the tissue recovers its own strength. The half-circle needle with cylindrical body and taper point (taperpoint) separates the fibres without a cutting effect, minimising trauma to delicate structures. The violet colour of the thread ensures optimal visibility on the surgical field throughout the procedure. The product is supplied sterile by ethylene oxide (EtO), is single-use and does not allow re-sterilisation.
3.1. General characteristics of reference 1L13HR2620
| Characteristic | Specification |
| Reference (SKU) | 1L13HR2620 |
| Brand / Quality | Premisut – Normal quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Suture type | Synthetic absorbable multifilament |
| Thread structure | Braided coated multifilament, fluted finish |
| Thread colour | Violet (colourless version available in the family) |
| Gauge | USP 2/0 (metric 3) |
| Approximate diameter | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
| Thread length | 90 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 26 mm |
| Absorption mechanism | Hydrolysis (56 – 72 days) |
| Sterilisation | Ethylene oxide (EtO), sterile, single-use |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
| Absorption type | Hydrolysis |
| Absorption time | 56 – 72 days |
| Tensile strength at 2 weeks | 75 % |
| Tensile strength at 3 weeks | 50 % |
| Tensile strength at 4 weeks | 30 % |
| Tissue reaction | Minimal |
| Knot tying | Excellent safety |
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.349 mm (indicative according to Pharmacopoeia) |
Indications: approximation of soft tissues, ligatures and ophthalmic surgery. Price per box of 12 units; consult B2B conditions for orders in multiples of boxes.
Polyglactin 910 is the most widely used absorbable multifilament material in surgical practice. This reference presents an absorption profile (56-72 days) and tensile strength retention equivalent to that of the braided polyglactin 910 lines from the main international manufacturers:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided coated polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided PGLA range) |
| SMI | Surgicryl (absorbable polyglactin 910) |
| Assut | Assucryl 910 |
| DemeTECH | DemeCRYL (polyglactin 910) |
| Dolphin Sutures | Petcryl 910 |
| CPT Sutures | CARESORB (polyglactin 910) |
| Laboratorio Aragó (Premisut range) | PGLA multifilament with ½ circle cylindrical needle (HR series) |
Within the Cahnos catalogue, the same configuration (HR 26 mm needle, USP 2/0 gauge, 90 cm violet thread) is available in Prime quality under reference P1L13HR2620, and in a 75 cm format under reference 1L12HR2620. As an alternative in polyglycolic acid (PGA), with absorption of 60-90 days, reference AM113HR2620 may be considered. The indicated equivalences are for guidance; for a formal substitution of references, please consult our technical-commercial department.
The USP 2/0 gauge (metric 3) offers an excellent balance between initial strength and handling for soft tissues under moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The half-circle taper point (taperpoint) needle is the most atraumatic option for delicate tissues; if greater penetration in firm tissues is required, consider the trocar points (HRT) or reverse cutting points (HS) available in the same range.
| Reference | Variant |
| 1L13HR2620 | PGLA USP 2/0, HR 26 mm needle, violet, 90 cm (current product) |
| 1L12HR2620 | PGLA USP 2/0, HR 26 mm needle, violet, 75 cm (shorter thread length) |
| P1L13HR2620 | PGLA Prime USP 2/0, HR 26 mm needle, violet, 90 cm (superior quality) |
| 1L13HR2630 | PGLA USP 3/0, HR 26 mm needle, colourless, 90 cm (finer gauge) |
| 1L18HRT2620 | PGLA USP 2/0, HRT 26 mm trocar point needle, violet, 70 cm (denser tissues) |
| 1L28HR2620 | PGLA USP 2/0, HR 26 mm needle, colourless, 70 cm (discretion in the field) |
| 1L13HR3620 | PGLA USP 2/0, HR 36 mm needle, violet, 90 cm (larger needle) |
| P1L18HR2620VB | PGLA Prime VisiBlack USP 2/0, HR 26 mm needle, violet, 70 cm (high visibility) |
| AM113HR2620 | PGA USP 2/0, HR 26 mm needle, violet, 90 cm (absorption 60-90 days) |
If you need a longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalences from other commercial houses, contact the technical-commercial team at Cahnos.