Description
1. Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture of Prime quality from the Premisut range is the reference choice in the operating theatre for operating theatres, private clinics, ophthalmologists and purchasing centres seeking a high-performance synthetic suture with excellent value for money. This reference features a half-circle needle with cylindrical body and Taperpoint conical tip of 45 mm (HR45 needle), USP size 1 and violet grooved thread of 70 cm, under the code P1L18HR4501.
Each unit is supplied sterile and ready to use, with the warranty of professional distribution by Cahnos for private clinics, hospitals and wholesalers in the sector. Especially indicated for the approximation of soft tissues, ligatures and ophthalmic surgery, where precision, handling and fully predictable absorption are required during the first weeks of healing.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish gives it great flexibility, low memory and a low coefficient of friction, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it ideal for tissues that require wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The half-circle needle with cylindrical body and conical tip (Taperpoint) separates the fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery. The violet colour ensures optimal visibility of the thread in the surgical field. Sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P1L18HR4501
| Characteristic | Specification |
| Reference (SKU) | P1L18HR4501 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet |
| Thread length | 70 cm (1 thread) |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | 45 mm (HR 45 Prime) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period | Remaining tensile strength |
| 2 weeks | 75% of initial strength |
| 3 weeks | 50% of initial strength |
| 4 weeks | 30 % of initial strength |
| Total absorption | 56 – 72 days, by hydrolysis |
Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures with medium absorption, clinically equivalent to the reference polyglactin 910 sutures on the international market:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series) |
Within the Cahnos catalogue, its direct equivalent in structure, needle and size is reference P1L13HR4501 (PGLA Prime, HR 45 mm needle, USP size 1, violet, 90 cm thread), ideal when a longer thread length per unit is preferred. As an alternative in polyglycolic acid, reference AMP113HR4501 (PGA Prime, same HR 45 mm needle, USP size 1, violet, 90 cm) is available.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the size according to the anatomical area. USP size 1 is indicated for tissues that require high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. The Taperpoint conical tip is ideal for soft and delicate tissues; for fibrous structures or the sclera, consider reverse cutting or trocar points.
| Reference | Variant |
| P1L18HR4501 | PGLA Prime USP 1, HR 45 mm needle, violet, 70 cm (current product) |
| P1L13HR4501 | PGLA Prime USP 1, HR 45 mm needle, violet, 90 cm (longer thread) |
| P1L18HR4502 | PGLA Prime USP 2, HR 45 mm needle, violet, 70 cm (larger size) |
| P1L18HR4001 | PGLA Prime USP 1, HR 40 mm needle, violet, 70 cm (shorter needle) |
| P1L12HR4501H | PGLA Prime Heavy USP 1, HR 45 mm needle, violet, 2 x 90 cm (higher performance) |
| AMP113HR4501 | PGA Prime USP 1, HR 45 mm needle, violet, 90 cm (polyglycolic acid alternative, absorption 60-90 days) |
If you need longer strength retention (180 to 210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.