Description
1. Commercial Introduction
The Absorbable Multifilament PGLA Suture (Polyglactin 910) from the Prime range by Premisut, reference P1L13HR3601.2, is the reference solution in the operating theatre for hospitals, private clinics, ophthalmologists and purchasing centres looking for a high-performance synthetic absorbable thread with a very competitive price-quality ratio.
This presentation in double format of 2 threads of 90 cm maximises profitability per pack and guarantees continuity of supply in procedures that require several sutures per session. Each unit is supplied sterile, ready to use and single-use, with the guarantee of professional distribution from Cahnos.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide. Its braided multifilament structure with a grooved finish gives it great flexibility, low memory and a low coefficient of friction, which favours thread sliding through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. This profile makes it suitable for tissues that require wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own strength.
The ½ circle needle with cylindrical body and conical tip (taperpoint) of 36 mm penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery and for approximating soft tissues. The violet colour of the thread guarantees optimal visibility in the surgical field. Product sterile by ethylene oxide, single-use and not resterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P1L13HR3601.2
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L13HR3601.2 |
| Brand / Quality | Premisut – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet (D&C Violet No. 2 dye); colourless version available in the family |
| Length and format | 2 threads of 90 cm (double format) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 36 mm (HR 36 Prime) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.
3.3. Presentation and ordering conditions
| Value | Value |
|---|---|
| Reference (SKU) | P1L13HR3601.2 |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Format | Sterile, single-use, 2 threads of 90 cm per pack |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most proven synthetic absorbable suture raw materials on the market. This braided multifilament suture of medium absorption is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle cylindrical needles (TC/HR series) |
Within the Cahnos catalogue, its direct equivalent in single thread format of 90 cm is reference P1L13HR3601, and the 70 cm version is P1L18HR3601; the standard quality without Prime corresponds to reference 1L13HR3601. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 1 (metric 4) gauge is indicated for tissues requiring high initial strength: aponeurosis, fascia, muscle planes, abdominal wall and high-tension closures. The ½ circle needle with conical taperpoint tip of 36 mm is ideal for soft and delicate tissues, with special application in ophthalmic surgery; for firmer and denser structures (e.g. sclera) reverse cutting or trocar points are recommended.
| Reference | Variant |
|---|---|
| P1L13HR3601.2 | PGLA Prime USP 1, HR 36 mm needle, violet, 2 x 90 cm (current product) |
| P1L13HR3601 | PGLA Prime USP 1, HR 36 mm needle, violet, 1 x 90 cm (single thread) |
| P1L18HR3601 | PGLA Prime USP 1, HR 36 mm needle, violet, 70 cm (shorter length) |
| P1L13HR3602 | PGLA Prime USP 2, HR 36 mm needle, violet, 90 cm (larger gauge) |
| P1L13HR3610 | PGLA Prime USP 0, HR 36 mm needle, violet, 90 cm (fine gauge) |
| P1L13HS3601 | PGLA Prime USP 1, triangular reverse cutting needle HS 36 mm, violet, 90 cm (firm tissues) |
| P1L13HRT3601 | PGLA Prime USP 1, trocar needle HRT 36 mm, violet, 90 cm (firm penetration) |
| P1L13HRN3601H | PGLA Prime Heavy USP 1, blunt tip needle HRN 36 mm, violet, 90 cm (maximum atraumatic) |
| AMP113HR3601 | PGA Prime USP 1, HR 36 mm needle, violet, 90 cm (absorption 60-90 days) |
The double format of 2 threads of 90 cm is especially cost-effective in departments with a high volume of sutures per procedure. If you need longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in a box of 12 units, with a minimum order of 30 boxes to guarantee continuous supply for your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact our technical-commercial team.