Description
1. Product Presentation
The absorbable multifilament suture of polyglactin 910 (PGLA) Ref. 1L18HRT2620, from the Premisut line, is the professional solution for the surgeon who demands secure closure, reliable knotting and fully predictable reabsorption. It incorporates a ½ circle needle with cylindrical body and trocar point (tapercut) of 26 mm, violet thread of 70 cm and USP 2/0 gauge (metric 3). It is supplied in a box of 12 units with a minimum order of 30 boxes, and is a reference option for tissue approximation, ligatures and ophthalmic surgery. Synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio for B2B supply to operating theatres, ophthalmology clinics and purchasing centres.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with body fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and trocar point (tapercut geometry) combines a rounded body with a cutting point, allowing it to pass through tissues of some resistance with moderate effort and minimise tissue tearing when passing the thread. It is the usual configuration in ophthalmic surgery and in the approximation of moderately dense soft tissues. The product is sterilised by ethylene oxide, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference 1L18HRT2620
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Normal (Premisut range) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Tip type | Trocar / Tapercut |
| Needle size | HRT 26 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (single-use) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | 1L18HRT2620 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, its direct equivalent in Prime quality with the same configuration (HRT 26 mm needle, USP 2/0 gauge and 70 cm thread) is reference P1L18HRT2620. The version with a dark high-visibility needle corresponds to reference P1L18HR2620VB (HR 26 mm VisiBlack needle, conical point).
5. Selection tips and variants of interest
USP 2/0 gauge (metric 3) is ideal for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The 26 mm trocar point needle is especially recommended in medium-density tissues and in procedures where a clean, tear-free passage is sought, such as ophthalmic surgery.
Variants of interest in the Cahnos catalogue:
- 1L18HRT2630: same HRT 26 mm needle, USP 3/0 gauge, violet, 70 cm (finer gauge for greater precision).
- P1L18HRT2630: Prime version of gauge 3/0 with HRT 26 mm needle.
- 1L12HR2620: cylindrical needle with conical point HR 26 mm, USP 2/0, violet, 75 cm (more atraumatic point).
- 1L13HR2620: HR 26 mm needle, USP 2/0, violet, 90 cm (greater thread length).
- 1L28HR2620: HR 26 mm needle, USP 2/0, colourless thread, 70 cm.
- AM112HRT2620: alternative in polyglycolic acid (PGA) with HRT 26 mm needle, USP 2/0, violet, 75 cm (absorption 60–90 days).
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. Keep the original packaging in a dry, cool place, respect the expiry date and handle the thread with gloves to avoid altering its mechanical properties. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.