We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA Polyglactin 910 Prime | 1/2 Circle Cylindrical Body Trocar Tapercut Needle HRT 36 mm | USP 2/0 | Violet 90 cm | Ref. P1L13HRT3620 | Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA), range Premisut Prime, with a ½ circle needle, cylindrical body and 36 mm trocar point (tapercut) (HRT36). USP 2/0 size with 90 cm violet grooved thread. Copolymer of 90% glycolide and 10% L-lactide, predictable hydrolysis absorption between 56 and 72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction, excellent handling and optimal knot security for tissue approximation, ligatures and ophthalmic surgery. Reference P1L13HRT3620, presentation in a box of 12 units with a minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L13HRT3620

Description

1. Introduction

The Absorbable Multifilament Suture PGLA (Polyglactin 910) from the Prime line, reference P1L13HRT3620, is the technical reference solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circle needle with cylindrical body and 36 mm trocar point (HRT36) allows firm and controlled penetration, while the 90 cm violet grooved thread guarantees optimal visibility over the surgical field.

It is a synthetic, absorbable, sterile and single-use medical device, with a very competitive price-quality ratio for B2B procurement of operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, which ensures the continuous supply of your healthcare centre.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, smooth handling and firm, secure knot tying, even in medium sizes such as USP 2/0.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and 36 mm trocar point (tapercut) penetrates tissues of moderate or slightly fibrous tension with controlled trauma. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L13HRT3620

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Quality Prime (Premisut range)
Gauge USP 2/0 (metric 3)
Thread colour Violet
Needle shape ½ circle, cylindrical body
Tip type Trocar / Tapercut
Needle size HRT 36 mm
Thread length 90 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L13HRT3620

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglactin 910 is one of the most well-established synthetic absorbable suture raw materials on the market and clinically corresponds to the same chemical family used by international reference lines:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic Polysorb (absorbable braided range of polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ½ circle needles (470xx series and HRT/HS series)

Within the Cahnos catalogue, it is part of the HRT36 trocar needle family in violet with its corresponding sizes: P1L13HRT3601 (USP 1), P1L13HRT3610 (USP 0) and P1L13HRT3630 (USP 3/0), all in 90 cm violet thread. In the polyglycolic acid (PGA) family, the performance equivalent with the same HRT36 needle is reference AMP113HRT3620 (USP 2/0, violet, 90 cm), with an absorption profile of 60 to 90 days.

5. Selection tips and variants of interest

The USP 2/0 size (metric 3) is indicated for soft tissues of moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The 36 mm HRT trocar point needle is especially recommended for firm or slightly fibrous tissues, where the passage must be clean and without tearing; if a fully atraumatic conical point is preferred, HR versions of 36 mm are available in the same range. For procedures on very friable tissues or where minimal thread visibility is required, the colourless version of the family (P1L23HRT3601) can be considered. For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA) – copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

Quality

Prime (Premisut range)

Gauge

USP 2/0 (metric 3)

Needle shape

1/2 circle, cylindrical body

Sterilisation

Ethylene oxide

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Reference

P1L13HRT3620

Use

Single-use, not re-sterilisable

Medida de aguja

HRT 36

Usp

2/0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA Polyglactin 910 Prime | 1/2 Circle Cylindrical Body Trocar Tapercut Needle HRT 36 mm | USP 2/0 | Violet 90 cm | Ref. P1L13HRT3620 | Box of 12 units”

Your email address will not be published. Required fields are marked *