We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | Double Needle ½ Circle Cylindrical Body Trocar Point Tapercut 2xHRT 40 mm | USP Size 1 (Metric 4) | Violet Fluted Thread 70 cm | Ref. 1L18HRT4001-2 – Box of 12 units

Original price was: 39,90 €.Current price is: 29,80 €.

Absorbable multifilament suture of polyglactin 910 (PGLA) from the Premisut range, in a double needle ½ circle with trocar point (Tapercut) 40 mm configuration. USP size 1 (metric 4), 70 cm violet braided fluted thread and predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterilised by ethylene oxide, single-use, with minimal tissue reaction, excellent tensile strength and optimal knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units with a minimum order of 30 boxes. Ref. 1L18HRT4001-2.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L18HRT4001-2

Description

1. Commercial Introduction

The absorbable multifilament suture of Polyglactin 910 (PGLA), reference 1L18HRT4001-2 from the Premisut range, is the reference surgical closure solution for hospitals, ophthalmic clinics, private operating theatres and purchasing centres seeking a high-performance synthetic absorbable thread with an excellent quality-price ratio. Its double needle system, ½ circle with cylindrical body and trocar point (Tapercut) of 40 mm, USP 1 gauge (metric 4) and violet grooved thread of 70 cm, guarantees precision, manageability and fully predictable absorption during the first weeks of healing.

Each unit is supplied sterile and ready to use, with the guarantee of professional distribution by Cahnos. It is especially indicated for tissue approximation, ligatures and ophthalmic surgery, where controlled penetration, knot security and minimal tissue reaction are required.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, configured in a braided multifilament structure with a grooved finish. This configuration provides great flexibility, low memory and a contained friction coefficient, which favours thread sliding through tissue, very smooth handling and firm, secure knot tying, even in larger gauges such as USP 1.

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it suitable for tissues requiring wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance.

The ½ circle needle with cylindrical body and trocar point (Tapercut profile) combines easy, controlled penetration with a contained cutting effect, making it especially effective in firm, dense tissues such as the sclera and fibrous tissues, while minimising trauma to adjacent structures. The double needle format with two 70 cm threads optimises use per package and is very practical for continuous suture procedures. The violet colour guarantees optimal thread visibility in the surgical field. Sterile single-use product, not suitable for re-sterilisation.

3. Technical Specifications

3.1. General characteristics of reference 1L18HRT4001-2

Reference (SKU) 1L18HRT4001-2
Brand / Range Premisut (PREMISUT) – Normal quality
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 1 (metric 4)
Thread colour Fluted violet (high visibility)
Configuration Double needle, 2 threads of 70 cm per pack
Thread length 70 cm
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 2xHRT 40 mm
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 30 % of initial tensile strength
Total absorption 56-72 days (by hydrolysis)

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widely used synthetic absorbable materials on the European market. This reference, by composition (90/10 copolymer), braided structure, ethylene oxide sterilisation and hydrolysis absorption profile in the 56 to 72 day range, is clinically comparable to the braided multifilament sutures of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ½ circle needles (TC / HR / HRT series)

Within the Cahnos catalogue, its direct equivalent in the same double trocar needle configuration is reference P1L18HRT4001-2 (Prime quality, same needle geometry, gauge, colour and thread length). As an alternative in polyglycolic acid (PGA) with the same HRT 40 mm needle, references AM118HRT4001-2 (Normal quality) and AMP118HRT4001-2 (Prime quality) are available, with absorption of 60 to 90 days. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 gauge (metric 4) is indicated for tissues requiring high initial resistance: aponeurosis, fascia, muscular planes and high-tension closures. The trocar point (Tapercut) combines penetration and control in firm, dense tissues; for soft, friable tissues, conical Taperpoint points are recommended, and for very delicate structures, reverse cutting points (HS).

Reference Recommended variant
1L18HRT4001-2 PGLA USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (current product)
P1L18HRT4001-2 PGLA Prime USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (superior quality)
AM118HRT4001-2 PGA USP 1, double trocar needle 2xHRT 40 mm, violet, 70 cm (absorption 60-90 days)
1L18HR4001 PGLA USP 1, HR 40 mm conical Taperpoint needle, violet, 70 cm (more atraumatic)
1L18HS4001 PGLA USP 1, HS 40 mm reverse cutting triangular needle, violet, 70 cm (firm tissues)
1L13HR4001 PGLA USP 1, HR 40 mm needle, violet, 90 cm (longer thread length)
1L18HRT1740 PGLA USP 4/0, HRT 17 mm trocar needle, violet, 70 cm (fine gauges and ophthalmic)
P1L13RHRP4801 PGLA Prime USP 1, Ultra Plus 48 mm conical needle (HRP48), violet, 90 cm (deep field)

If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, see the fast-absorbing polyglactin 910 range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare facility. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B volume conditions, hospital supply contracts or equivalents from other manufacturers, contact our technical-commercial team.

Additional information

Reference

1L18HRT4001-2

Brand

Premisut (PREMISUT)

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament with grooved finish

USP size

1 (metric 4)

Metric gauge (EP)

4

Thread colour

Violet grooved

Configuration

Double needle, 2 threads of 70 cm per pack

Needle body

Cylindrical

Needle size

2xHRT 40 mm

Sterilisation

Ethylene oxide (EO), sterile, single-use

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Use

Single-use, do not re-sterilise

Medida de aguja

2xHRT 40

Usp

1

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | Double Needle ½ Circle Cylindrical Body Trocar Point Tapercut 2xHRT 40 mm | USP Size 1 (Metric 4) | Violet Fluted Thread 70 cm | Ref. 1L18HRT4001-2 – Box of 12 units”

Your email address will not be published. Required fields are marked *