Description
1. Introduction
The multifilament absorbable suture of Polyglactin 910 (PGLA) from the Prime range by Premisut is the reference choice in the operating theatre for hospitals, ophthalmology clinics, private operating theatres and purchasing centres looking for a high-performance synthetic absorbable thread with an excellent quality-price ratio. This reference features a double needle ½ circle with cylindrical body and trocar point (Tapercut) of 40 mm, USP 1 gauge (metric 4) and violet fluted thread of 70 cm, under code P1L18HRT4001-2.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution by Cahnos. Especially indicated for tissue approximation, ligatures and ophthalmic surgery, where precision, handling and totally predictable absorption during the first weeks of healing are required.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its multifilament braided structure with fluted finish gives it great flexibility, low memory and a low coefficient of friction, which favours thread sliding through tissue, very smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 1.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it ideal for tissues that require wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and trocar point (Tapercut profile) combines easy, controlled penetration with a contained cutting effect, making it especially effective in firm, dense tissues, such as the sclera and fibrous tissues, minimising trauma to adjacent structures. The double needle format with two 70 cm threads optimises utilisation per package and is very practical for continuous suture procedures. The violet colour ensures optimal thread visibility in the surgical field. Sterile single-use product, not for re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L18HRT4001-2 |
| Brand / Quality | Premisut (PREMISUT) – Prime |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 1 (metric 4) |
| Thread colour | Violet grooved |
| Configuration | Double needle, 2 threads of 70 cm per pack |
| Thread length | 70 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Trocar (Tapercut) |
| Needle size | 2xHRT 40 mm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 56-72 days |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal, with excellent tensile strength and knot security |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 30 % of initial tensile strength |
| Total absorption | 56-72 days (by hydrolysis) |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most widespread synthetic absorbable materials on the European market. This reference, by composition (90/10 copolymer), braided structure, ethylene oxide sterilisation and hydrolysis absorption profile in the range of 56 to 72 days, is clinically comparable to the braided multifilament sutures of the main manufacturers:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (TC / HR / HRT series) |
Within the Cahnos catalogue, its direct equivalent in the same double needle trocar configuration is reference 1L18HRT4001-2 (standard quality, same needle geometry, gauge, colour and thread length). As an alternative in polyglycolic acid (PGA) with the same HRT 40 mm needle, reference AMP118HRT4001-2 is available (absorption 60 to 90 days). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 gauge (metric 4) is indicated for tissues that require high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. The trocar point (Tapercut) combines penetration and control in firm, dense tissues; for soft and friable tissues, Taperpoint conical points are recommended, and for very delicate structures, reverse cutting points (HS).
| Reference | Recommended variant |
|---|---|
| P1L18HRT4001-2 | PGLA Prime USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (current product) |
| 1L18HRT4001-2 | PGLA standard quality USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (Normal quality) |
| AMP118HRT4001-2 | PGA Prime USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (absorption 60-90 days) |
| P1L18HR4001 | PGLA Prime USP 1, HR 40 mm needle with Taperpoint conical point, violet, 70 cm (more atraumatic) |
| P1L18HS4001 | PGLA Prime USP 1, HS 40 mm reverse cutting triangular needle, violet, 70 cm (firm tissues) |
| P1L13HR4001 | PGLA Prime USP 1, HR 40 mm needle, violet, 90 cm (longer thread length) |
| P1L13RHRP4801 | PGLA Prime USP 1, Ultra Plus 48 mm conical needle (HRP48), violet, 90 cm (deep field) |
If you need a longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, consult the fast-absorbing polyglactin 910 range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other manufacturers, contact our technical-commercial team.