Absorbable Multifilament PGLA Polyglactin 910 Prime – Double Needle ½ Circle Cylindrical Body Trocar Point (Tapercut) 2xHRT 40 mm, USP 1 Gauge, Violet Thread 70 cm – Box of 12 units Ref. P1L18HRT4001-2

Original price was: 49,90 €.Current price is: 38,40 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) Prime quality from the Premisut range, presented in a configuration of double ½-circle needle with trocar point (Tapercut) 40 mm. USP 1 gauge (metric 4), violet fluted thread of 70 cm and predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterilised by ethylene oxide, single-use, with minimal tissue reaction, excellent tensile strength and optimal knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units with a minimum order of 30 boxes. Ref. P1L18HRT4001-2.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18HRT4001-2

Description

1. Introduction

The multifilament absorbable suture of Polyglactin 910 (PGLA) from the Prime range by Premisut is the reference choice in the operating theatre for hospitals, ophthalmology clinics, private operating theatres and purchasing centres looking for a high-performance synthetic absorbable thread with an excellent quality-price ratio. This reference features a double needle ½ circle with cylindrical body and trocar point (Tapercut) of 40 mm, USP 1 gauge (metric 4) and violet fluted thread of 70 cm, under code P1L18HRT4001-2.

Each unit is supplied sterile and ready to use, with the guarantee of professional distribution by Cahnos. Especially indicated for tissue approximation, ligatures and ophthalmic surgery, where precision, handling and totally predictable absorption during the first weeks of healing are required.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its multifilament braided structure with fluted finish gives it great flexibility, low memory and a low coefficient of friction, which favours thread sliding through tissue, very smooth handling and firm, secure knot tying, even in larger diameter gauges such as USP 1.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it ideal for tissues that require wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance.

The ½ circle needle with cylindrical body and trocar point (Tapercut profile) combines easy, controlled penetration with a contained cutting effect, making it especially effective in firm, dense tissues, such as the sclera and fibrous tissues, minimising trauma to adjacent structures. The double needle format with two 70 cm threads optimises utilisation per package and is very practical for continuous suture procedures. The violet colour ensures optimal thread visibility in the surgical field. Sterile single-use product, not for re-sterilisation.

3. Technical Specifications

Characteristic Specification
Reference (SKU) P1L18HRT4001-2
Brand / Quality Premisut (PREMISUT) – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 1 (metric 4)
Thread colour Violet grooved
Configuration Double needle, 2 threads of 70 cm per pack
Thread length 70 cm
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Trocar (Tapercut)
Needle size 2xHRT 40 mm
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75% of initial tensile strength
3 weeks 50% of initial tensile strength
4 weeks 30 % of initial tensile strength
Total absorption 56-72 days (by hydrolysis)

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery.

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widespread synthetic absorbable materials on the European market. This reference, by composition (90/10 copolymer), braided structure, ethylene oxide sterilisation and hydrolysis absorption profile in the range of 56 to 72 days, is clinically comparable to the braided multifilament sutures of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
Laboratory Aragó Polyglactin 910 range with ½ circle needles (TC / HR / HRT series)

Within the Cahnos catalogue, its direct equivalent in the same double needle trocar configuration is reference 1L18HRT4001-2 (standard quality, same needle geometry, gauge, colour and thread length). As an alternative in polyglycolic acid (PGA) with the same HRT 40 mm needle, reference AMP118HRT4001-2 is available (absorption 60 to 90 days). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 gauge (metric 4) is indicated for tissues that require high initial resistance: aponeurosis, fascia, muscle planes and high-tension closures. The trocar point (Tapercut) combines penetration and control in firm, dense tissues; for soft and friable tissues, Taperpoint conical points are recommended, and for very delicate structures, reverse cutting points (HS).

Reference Recommended variant
P1L18HRT4001-2 PGLA Prime USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (current product)
1L18HRT4001-2 PGLA standard quality USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (Normal quality)
AMP118HRT4001-2 PGA Prime USP 1, double needle trocar 2xHRT 40 mm, violet, 70 cm (absorption 60-90 days)
P1L18HR4001 PGLA Prime USP 1, HR 40 mm needle with Taperpoint conical point, violet, 70 cm (more atraumatic)
P1L18HS4001 PGLA Prime USP 1, HS 40 mm reverse cutting triangular needle, violet, 70 cm (firm tissues)
P1L13HR4001 PGLA Prime USP 1, HR 40 mm needle, violet, 90 cm (longer thread length)
P1L13RHRP4801 PGLA Prime USP 1, Ultra Plus 48 mm conical needle (HRP48), violet, 90 cm (deep field)

If you need a longer force retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos; for faster absorption, consult the fast-absorbing polyglactin 910 range (PGLAR type). All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. As it is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply contracts or equivalents from other manufacturers, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 1 (metric 4)

Colour

Violet grooved

Configuration

Double needle, 2 threads of 70 cm per pack

Needle body

Cylindrical

Needle size

2xHRT 40 mm

Absorption mechanism

Hydrolysis

Strength retention

75% at 2 weeks, 50% at 3 weeks, 30% at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Quality

Prime (Premisut range)

Medida de aguja

2xHRT 40 prime

Usp

1

Color

Violet

Medida de hilo

70 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)