Description
1. Product Presentation
The absorbable multifilament PGLA Prime suture (Ref. P1L18HRT2630) from the Premisut line is the reference technical solution for professionals who require secure closure, reliable knotting and fully predictable reabsorption. It incorporates a ½ circle cylindrical needle with trocar point (tapercut) of 26 mm, violet grooved thread of 70 cm and USP gauge 3/0 (metric 2). It is supplied in a box of 12 units, with a minimum order of 30 boxes, and is a reference option for tissue approximation, ligatures and ophthalmic surgery. Synthetic absorbable medical device, sterile and single-use, with excellent value for money for B2B supply to operating theatres, ophthalmic clinics and purchasing centres.
2. Technical explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through the tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 3/0.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with cylindrical body and trocar point (tapercut geometry) combines a rounded body with a cutting point, allowing it to penetrate tissues of some resistance with moderate effort and minimise tissue tearing when passing the thread. It is the usual configuration in ophthalmic surgery and in the approximation of moderately dense soft tissues. The product is sterilised by ethylene oxide, is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L18HRT2630
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (Premisut range) |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet grooved |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Tip type | Trocar (tapercut) |
| Needle size | 26 mm (HRT 26) |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HRT2630 |
3.2. Tensile strength retention profile
| Period | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
Within the Cahnos catalogue, its standard quality equivalent with the same HRT 26 needle configuration, gauge 3/0 and 70 cm thread is reference 1L18HRT2630, and the version with a dark high-visibility needle corresponds to reference P1L18HR2630VB (HR 26 mm VisiBlack needle, conical point).
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP gauge 3/0 (metric 2) is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The 26 mm trocar point needle is especially recommended for medium-density tissues and in procedures where less tissue tearing is sought, such as ophthalmic surgery.
Variants of interest in the Cahnos catalogue:
- P1L18HRT2620: PGLA Prime ½ circle cylindrical trocar point HRT 26 mm, USP 2/0, violet, 70 cm (larger gauge).
- P1L18HR2640: PGLA Prime ½ circle cylindrical HR 26 mm, USP 4/0, violet, 70 cm (finer gauge for greater precision).
- P1L18HR2630VB: PGLA Prime ½ circle cylindrical HR 26 mm VisiBlack, USP 3/0, violet, 70 cm (more atraumatic conical point and maximum needle visibility).
- P1L18HS2630: PGLA Prime ½ circle reverse cutting triangular point HS 26 mm, USP 3/0, violet, 70 cm (cutting point for firm tissues).
- AMP112HRT2630: PGA ½ circle cylindrical trocar point HRT 26 mm, USP 3/0, violet, 75 cm (alternative in polyglycolic acid).
- AMP418HRT2630: PDO monofilament ½ circle trocar point HRT 26 mm, USP 3/0, violet, 70 cm (longer force retention, 180–210 days).
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare facility. Keep the original packaging in a dry, cool place, respect the expiry date and handle the thread with gloves to avoid altering its mechanical properties. For special B2B conditions and volume orders, contact our technical-commercial team.