Description
1. Commercial Introduction
The absorbable multifilament suture of Poliglactina 910 (PGLA) reference 1L18HS4010 is the reference technical solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in soft tissue approximation, ligatures and ophthalmic surgery. Its 1/2 circle needle with reverse cutting triangular point of 40 mm (HS 40) offers firm and controlled penetration, ideal for firm and dense tissues, while the violet braided thread of 70 cm ensures optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for B2B procurement of operating theatres, ophthalmology clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ensuring continuous supply for your healthcare centre.
2. Technical Explanation
Poliglactina 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, with high initial tensile strength.
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The 1/2 circle needle with triangular body and reverse cutting point (reverse cutting) of 40 mm penetrates firm and consistent tissues with controlled trauma, avoiding tears, being especially indicated for tissue approximation, ligatures and ophthalmic and general surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference 1L18HS4010
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Colour | Violet (also available colourless) |
| Needle shape | ½ circle |
| Tip type | Triangular with reverse cutting (triangular body and point) |
| Needle size | HS 40 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use, not re-sterilisable) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | 1L18HS4010 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75% |
| 3 weeks | 50% |
| 4 weeks | 30% |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament poliglactina 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Absorbable braided polyglactin 910 range |
| Aragó Laboratory (Aragó Sutures) | Polyglactin 910 range with ½ circle needles (HS / TC series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the poliglactina 910 family with Prime quality is reference P1L18HS4010 (same HS 40 mm triangular needle, USP 0, violet, 70 cm), ideal when seeking the top range. In the polyglycolic acid (PGA) family, AM118HS4010 stands out (same HS 40 mm triangular needle, USP 0, violet, 70 cm), recommended when a 60 to 90 day absorption profile is preferred. The version with a conical point in the same size is available as 1L18HR4010.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. Poliglactina 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks. The reverse cutting triangular point needle is indicated when firm tissues need to be penetrated without tearing, while the cylindrical variant (HR) is more atraumatic in delicate tissues.
| Reference | Variant |
|---|---|
| 1L18HS4010 | PGLA USP 0, HS 40 mm triangular needle, violet, 70 cm (current product) |
| 1L18HR4010 | PGLA USP 0, HR 40 mm cylindrical needle with conical point, violet, 70 cm (more atraumatic) |
| P1L13HS4010 | PGLA Prime USP 0, HS 40 mm triangular needle, violet, 90 cm (longer thread length) |
| 1L13HS4002 | PGLA USP 2, same HS 40 mm needle, violet, 90 cm (larger gauge for high tension) |
| 1L12DS4010 | PGLA USP 0, 3/8 triangular needle DS 40 mm, violet, 75 cm (another needle curve) |
| 1L18FR4010 | PGLA USP 0, FR 40 mm 5/8 cylindrical needle, violet, 70 cm (specialised ophthalmic use) |
| AM118HS4010 | PGA USP 0, HS 40 mm triangular needle, violet, 70 cm (absorption of 60 to 90 days) |
If you need longer strength retention or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos, with absorption of 180 to 210 days. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.