Description
1. Commercial Introduction
The multifilament absorbable suture of polyglactin 910 (PGLA) from the Prime range, reference P1L18HS2220, is the professional reference solution for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and excellent knot security in soft tissue approximation, ligatures and ophthalmic surgery.
Its ½ circle needle with 22 mm reverse cutting triangular point (HS 22) ensures firm and controlled penetration even in dense tissues, while the 70 cm fluted violet thread offers optimal visibility on the surgical field and smooth sliding during suturing. It is a synthetic absorbable medical device, sterile and single-use, with an excellent value-for-money ratio.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.
Absorption occurs by hydrolysis, i.e., degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point penetrates firm and non-compliant tissues with controlled trauma, avoiding tears, which is why it is especially indicated in tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and not to be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L18HS2220
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (inverted triangular) |
| Needle size | HS 22 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS2220 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically placed in the same family as the reference synthetic absorbable braided sutures on the international market, common in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer or commercial house | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (series C, TC and HS) |
Within the Cahnos catalogue, the references from the same PGLA Prime family with close configurations are P1L18HR2220VB (HR cylindrical needle 22 mm, gauge 2/0, violet, 70 cm), P1L12HR2220 (HR cylindrical needle 22 mm, gauge 2/0, violet, 75 cm) and P1L28HR2220 (HR cylindrical needle 22 mm, gauge 2/0, colourless, 70 cm).
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 gauge (metric 3) is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The reverse cutting triangular point needle is especially recommended in firm and non-compliant tissues, where the needle pass must be clean and without tearing.
Among the variants of interest in the same range, the P1L18HS3620 (HS triangular needle 36 mm, gauge 2/0, violet, 70 cm) stands out when a longer needle is required for deeper access. If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews