Absorbable Multifilament PGLA Polyglactin 910 Prime | 1/2 Circle Reverse Cutting Triangular Point Needle HS 26 mm | Gauge USP 1 (Metric 4) | Undyed 70 cm | Ref. P1L28HS2601 – Box of 12 units

25,42 €

Absorbable multifilament Polyglactin 910 (PGLA) suture from the Prime range, with a ½ circle 26 mm reverse cutting triangular point needle (HS26), gauge USP 1 (metric 4) and undyed fluted thread of 70 cm. It features predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Reference P1L28HS2601, presentation in box of 12 units with a minimum order of 30 boxes.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L28HS2601

Description

1. Introduction

The absorbable multifilament Polyglactin 910 (PGLA) suture from the Prime line, reference P1L28HS2601, is the professional reference solution for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and excellent knot security in soft tissue approximation, ligatures and ophthalmic surgery.

Its ½ circle reverse cutting triangular point needle of 26 mm ensures firm and controlled penetration even in dense tissues, while the undyed, fluted thread of 70 cm offers smooth glide during suturing. It is a synthetic absorbable medical device, sterile, single-use and with an excellent value for money.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates thread passage through tissue, smooth handling and firm, secure knot tying in medium gauges such as USP 1.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle reverse cutting triangular point (inverted triangle) needle of 26 mm penetrates firm and non-compliant tissues with controlled trauma, avoiding tears, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L28HS2601

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Quality Prime (range PREMISUT)
Gauge USP 1 (metric 4)
Thread colour Colourless
Needle shape ½ circle
Tip type Reverse cutting triangular (inverted triangular)
Needle size HS 26 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L28HS2601

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic Polysorb (absorbable braided range of polyglactin 910)
Laboratory Aragó Polyglactin 910 range with 1/2 circle needles (C / TC / HS series)

Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP128HS2601 (PGA, triangular needle HS 26 mm, USP 1, undyed, 70 cm), and in the same PGLA Prime range the variant with a more atraumatic conical point corresponds to reference P1L28HR2601 (cylindrical HR 26 mm, USP 1, undyed, 70 cm).

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. Gauge USP 1 (metric 4) is ideal for tissues with moderate to high tension, such as fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The 26 mm reverse cutting triangular needle is especially recommended for firm tissues and in ophthalmic surgery, where the needle passage must be clean and without tearing.

Reference Variant
P1L28HS2601 PGLA Prime USP 1, triangular needle HS 26 mm, undyed, 70 cm (current product)
P1L28HS2610 PGLA Prime USP 0, same needle HS 26 mm, undyed, 70 cm (smaller gauge)
P1L28HS3601 PGLA Prime USP 1, needle HS 36 mm, undyed, 70 cm (longer needle)
P1L18HS3601 PGLA Prime USP 1, needle HS 36 mm, violet, 70 cm (dyed thread for greater visibility)
P1L28HR2601 PGLA Prime USP 1, cylindrical needle HR 26 mm (conical point, more atraumatic)
AMP128HS2601 PGA Prime USP 1, needle HS 26 mm (absorption profile of 60 to 90 days)

If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in a box of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

Quality

Prime (PREMISUT)

USP size

1 (metric 4)

Tip type

Reverse cutting triangular (reverse cutting)

Absorption mechanism

Hydrolysis

Sterilisation

Ethylene oxide (EO)

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Reference

P1L28HS2601

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HS 26

Usp

1

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Polyglactin 910 Prime | 1/2 Circle Reverse Cutting Triangular Point Needle HS 26 mm | Gauge USP 1 (Metric 4) | Undyed 70 cm | Ref. P1L28HS2601 – Box of 12 units”

Your email address will not be published. Required fields are marked *