Description
1. Introduction
The Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture, reference P1L18HS3630, is the reference technical solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circular needle with reverse cutting triangular point of 36 mm (HS36) offers firm and controlled penetration, while the violet grooved thread of 70 cm guarantees optimal visibility over the surgical field and smooth sliding during suturing.
It is a synthetic absorbable medical device, sterile and single-use, with a very competitive price-quality ratio for the B2B supply of operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, which ensures the continuous supply of your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that favours the passage of the thread through the tissue, smooth handling and firm, secure knot tying, even in fine calibres such as USP 3/0.
Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile makes the suture ideal for tissues that require wound support during the first weeks of healing, maintaining the necessary tensile strength while the tissue recovers its own resistance. The ½ circular needle with reverse cutting triangular point (inverted triangle) of 36 mm penetrates firm and dense tissues with controlled trauma, being especially indicated in tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and without the possibility of re-sterilisation.
3. Technical Specifications
3.1. General characteristics of reference P1L18HS3630
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 3/0 (metric 2) |
| Colour | Violet grooved |
| Needle | ½ circle, triangular reverse cutting body and point |
| Needle size | HS 36 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS3630 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, common in general surgery, gynaecology, urology and specialised surgery:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (470xx series and HS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP118HS3630 (PGA, triangular needle HS36 mm, USP 3/0, violet, 70 cm). In the same PGLA Prime range, the variant with a conical point of 26 mm and VisiBlack needle is P1L18HR2630VB, and the colourless cylindrical version corresponds to reference P1L28HR3630.
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary calibre according to the anatomical area. USP 3/0 (metric 2) calibre is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The 36 mm reverse cutting triangular needle is especially recommended in firm tissues and ophthalmic surgery procedures, where the passage of the needle must be clean and without tearing.
- P1L12HR3630: PGLA Prime ½ circle cylindrical HR36 mm, USP 3/0, violet, 75 cm (conical point for soft tissues).
- P1L13HR3630: PGLA Prime ½ circle cylindrical HR36 mm, USP 3/0, violet, 90 cm (greater thread length).
- P1L18HR3610: PGLA Prime ½ circle cylindrical HR36 mm, USP 0, violet, 70 cm (larger calibre).
- P1L18HR3601: PGLA Prime ½ circle cylindrical HR36 mm, USP 1, violet, 70 cm (greater initial strength).
- AMP118HS3630: PGA ½ circle triangular HS36 mm, USP 3/0, violet, 70 cm (alternative in polyglycolic acid).
- 1L18HS2230: PGLA ½ circle triangular HS22 mm, USP 3/0, violet, 70 cm (shorter needle for delicate tissues).
For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.