Description
1. Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime range (PREMISUT), reference P1L18HS2630, is the technical reference solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its 1/2 circle needle with a 26 mm reverse cutting triangular point (HS 26) offers firm and controlled penetration even in dense and non-compliant tissues, while the 70 cm violet grooved thread guarantees optimal visibility on the surgical field and smooth sliding during suturing.
It is a synthetic absorbable, sterile, single-use medical device with an excellent quality-price ratio for the B2B supply of operating theatres, ophthalmic clinics and purchasing centres. Commercial presentation in a box of 12 units and a minimum order of 30 boxes, ensuring the continuous supply of your healthcare centre.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 3/0 (metric 2).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The 1/2 circle needle with triangular body and reverse cutting point (reverse cutting) of 26 mm penetrates firm tissues with controlled trauma, avoiding tears, which is why it is especially indicated in tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L18HS2630
| Characteristic | Specification |
|---|---|
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (triangular body and point, reverse cutting) |
| Needle size | HS 26 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS2630 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
|---|---|
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with 1/2 circle needles (C / TC / HS series) |
Within the Cahnos catalogue, its direct equivalent in structure and needle within the polyglycolic acid family is reference AMP118HS2630 (PGA, HS 26 mm triangular needle, USP 3/0, violet, 70 cm), and the standard range version PREMISUT corresponds to 1L18HS2630. In the same PGLA Prime range, the more atraumatic conical point variant with VisiBlack needle is reference P1L18HR2630VB (cylindrical HR 26 mm, USP 3/0, 70 cm non-grooved violet thread).
5. Selection tips and variants of interest
To choose the most appropriate suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. The USP 3/0 (metric 2) gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The 26 mm triangular reverse cutting needle is especially recommended in firm tissues and in ophthalmic surgery, where the passage of the needle must be clean and without tearing.
Variants of interest in the Cahnos catalogue:
- P1L18HS3630: PGLA Prime 1/2 circle triangular HS 36 mm, USP 3/0, violet, 70 cm (larger needle).
- P1L18HR2630VB: PGLA Prime 1/2 circle cylindrical HR 26 mm VisiBlack, USP 3/0, violet, 70 cm (conical point, more atraumatic).
- 1L18HS2610: PGLA 1/2 circle triangular HS 26 mm, USP 0, violet, 70 cm (standard range, larger gauge).
- AMP118HS2230: PGA 1/2 circle triangular HS 22 mm, USP 3/0, violet, 70 cm (shorter needle for delicate tissues).
- 1L18HS2230: PGLA 1/2 circle triangular HS 22 mm, USP 3/0, violet, 70 cm (shorter needle).
- P1L28HS2630: same configuration in colourless thread (greater aesthetic discretion).
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure the continuous supply of your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.