Description
1. Commercial Introduction
The absorbable monofilament suture PREMISUT POLIGLECAPRONE 25 (CAPROLACTONE PGCL) Prime is the reference solution for professionals seeking a short-to-medium absorption suture, excellent handling, secure knotting and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with an extra-long precision reverse cutting triangular point and a 13 mm square body (XDS 13 Prime profile), a cosmetic-type configuration designed for plastic, facial and delicate tissue surgery where controlled needle advancement is required without damaging the surrounding tissue. Its monofilament, non-serrated and colourless profile facilitates passage through tissue, reduces bacterial wicking compared with multifilament sutures and is ideal for intradermal closures and subcuticular sutures. Supplied sterile, single-use and in a box of 12 units, it is the ideal choice for purchasing departments, hospitals and clinics seeking to unify their absorbable suture portfolio with a single B2B supplier.
2. Technical Explanation
Polyglecaprone 25 (PGCL, a copolymer of glycolide and ε-caprolactone) is an absorbable synthetic polyester presented as an uncoated, non-serrated monofilament: lacking interstices, it minimises friction and bacterial wicking, passes through tissue smoothly and reduces tissue reaction. Its absorption occurs by hydrolysis over a predictable period of 90 to 120 days, with a tensile strength retention of 60% at the first week and 30% at two weeks, making it suitable for rapidly healing tissues that require firm initial support.
The XDS 13 Prime needle (⅜ circle, extra-long precision reverse cutting triangular point, Reverse Extra Cutting, with a 13 mm square body) presents the cutting edge outward at the moment of passage, allowing it to penetrate firm, non-distensible tissues with a clean cut without tearing. The square body improves grip in the needle holder and reduces needle rotation during suturing, a finish especially valued in aesthetic surgery. The USP 6/0 (metric EP 0.7) gauge offers the fineness required for delicate tissues, and the colourless (clear) colour makes it particularly suitable for subcuticular and intradermal sutures where an invisible aesthetic finish is sought.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the PGCL Prime range.
| Parameter | Specification |
| Thread material | Polyglecaprone 25 (PGCL), synthetic absorbable monofilament, non-serrated |
| Gauge / size | USP 6/0 (metric EP 0.7) |
| Thread length | 45 cm (1 suture · 1 needle per unit) |
| Thread colour | Colourless (highly discreet, ideal for subcuticular) |
| Needle shape | ⅜ circle (3/8 circular) |
| Tip type | Triangular reverse cutting, extra-long precision (Reverse Extra Cutting) |
| Needle body | Square (cosmetic), non-serrated |
| Needle size | 13 mm (XDS 13 Prime profile) |
| Absorption type | By hydrolysis, between 90 and 120 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use product |
| Tissue reactivity | Minimal; excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures, general, plastic and aesthetic surgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 10 boxes |
| Factory reference | P321XDS1360 (SKU Cahnos: AMP321XDS1360) |
Tensile strength retention:
| Period | Tensile retention |
| 1 week | 60 % |
| 2 weeks | 30 % |
4. Equivalences and Cross-References
Polyglecaprone 25 is the most widely used family of short-to-medium absorption monofilament absorbable sutures on the market, especially in the cosmetic and subcuticular segment. After verification in official manufacturer catalogues and regulatory sources, the following comparable reference by category is identified: the polymer base, USP 6/0 gauge, suture length, colourless colour and needle geometry (⅜ circle, reverse cutting precision, 13 mm) match, although the XDS 13 Prime geometry with cosmetic square body is only fully safely interchangeable within the Prime range system itself.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | MONOCRYL® (polyglecaprone 25), colourless monofilament | Y492G | Comparable by category (not interchangeable 1:1) | MONOCRYL 6/0, 45 cm (18″), colourless, P-3 needle of ⅜ circle reverse cutting precision point of 13 mm. Material (polyglecaprone 25), gauge 6/0, length, colour and needle size match; the needle body differs (standard P-3 versus XDS with cosmetic square body); confirm IFU before substituting. |
There is no equivalence table validated by the manufacturer for this specific reference; consult the technical department before use in tenders or direct substitution. Other homologous polyglecaprone 25 lines on the market require case-by-case verification of needle geometry, exact material and colour before any substitution.
5. Selection tips and variants of interest
The XDS needle (extra-long precision reverse cutting with square body) is the cosmetic variant of the PGCL Prime family: its square body facilitates grip in the needle holder and reduces needle rotation, ideal for plastic surgery, facial surgery and delicate tissues. For procedures on smaller areas or paediatric procedures, the same configuration in a smaller size within the same line may be considered: XDS 11 mm (SKU AMP321XDS1160) maintaining gauge 6/0, undyed colour and 45 cm. If a standard reverse cutting needle is preferred, the variant DS 12 mm (SKU AMP321DS1260) is available; if a ½ circle taper-point needle for soft tissues is required, the HR 13 mm (SKU AMP311HR1360) in gauge 6/0, violet and 45 cm. For a more prolonged absorption profile, the polydioxanone (PDO/PDS) monofilament sutures from the same line may be considered. Always verify the radius, needle size, USP gauge and point family required in your surgical protocol, as well as the current minimum order.





Reviews