Description
1. Commercial Introduction
We offer you the absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone) from the PREMISUT Prime range, factory reference P322DS3030.2 (SKU Cahnos AMP322DS3030.2), in a professional double-thread presentation: 2 colourless grooved strands of 75 cm in USP 3/0 gauge, mounted on a ⅜ circle needle with a triangular reverse cutting grooved point of 30 mm (DS30 Prime profile). It is the ideal B2B supply solution for operating theatres, general, digestive, gynaecology and urology surgery services, and purchasing centres looking for a synthetic absorbable thread with exceptional handling, firm knotting, minimal tissue reaction and complete batch traceability. Each unit is delivered sterile, ready for immediate use, in a box of 12 units in individual sachets.
2. Technical explanation of the material and procedure
Poliglecaprone 25 (PGCL) is a synthetic copolymer of poly(glycolic acid 75% – co-caprolactone 25%) in an uncoated monofilament structure. Its single-strand design reduces drag (saw effect) during passage through tissue, minimises capillarity and provides excellent handling smoothness and knot security compared with braided multifilaments. Absorption occurs by controlled hydrolysis over a period of 90 to 120 days (medium absorption), with an approximate retention of original strength of 60% at 7 days and 30% at 14 days post-implantation, comfortably covering the critical healing phase of most soft tissues. It is not recommended when prolonged tissue support is required. The DS30 needle of 30 mm, with ⅜ circle curvature and a grooved triangular reverse cutting point, concentrates the cutting edge on the outer face of the curvature: it penetrates firm, non-distensible tissues (skin, aponeurosis, dense subcutaneous tissue) with minimal resistance and better aesthetic results, preventing the cut from widening in the puncture bed. The double presentation 2×75 cm allows two strands per pack for continuous or multi-point sutures without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P322DS3030.2
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range, grooved needle) |
| Factory reference | P322DS3030.2 |
| Reference Cahnos (SKU) | AMP322DS3030.2 |
| Thread material | Poliglecaprone 25 (PGCL) – copolymer 75 % glycolic acid / 25 % ε-caprolactone |
| Thread structure | Synthetic absorbable monofilament, grooved surface |
| Coating | Uncoated |
| Gauge / size | USP 3/0 (metric EP 2), conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 2 × 75 cm (double strand) |
| Thread colour | Colourless (grooved) |
| Needle shape | 3/8 circle (⅜ circular), body and point |
| Tip type | Triangular reverse cutting (Reverse Cutting), grooved |
| Needle size | DS30 Prime (30 mm) |
| Swaged | 2 needles / 2 threads of 75 cm per unit |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90 – 120 days |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Soft tissue approximation and general ligatures |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
| Storage | Below 30 °C, away from moisture and direct sunlight |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
3.3. Gauge equivalence according to USP / EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
Reference P322DS3030.2 corresponds to the official nomenclature of the PREMISUT Prime range (DS30 profile: ⅜ circle needle with triangular reverse cutting point of 30 mm, USP 3/0 gauge, colourless grooved thread of 75 cm, double presentation 2×75 cm) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Poliglecaprone 25 is one of the most standardised synthetic absorbable monofilaments with medium absorption on the international market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference in the category, along with homologous families such as MONOSYN® (B. Braun, based on glyconate, with different degradation kinetics) and the PGCL lines from DemeTECH (DemeCAPRONE), SMI (Caprofyl®), Healthium (Monoglyde®), Assut Medical, Dolphin Sutures (Petcryl Mono), WEGO and CP Medical. No code from another manufacturer combining the exact configuration of this product —USP 3/0 gauge, DS30 needle of 30 mm, ⅜ circle curvature, triangular reverse cutting point, colourless thread of 75 cm and double armed 2×75 cm— has been found in official catalogues or regulatory databases (GUDID/EUDAMED); the codes documented in official sources for homologous families with 3/8 circle needles and reverse cutting correspond mostly to short plastic surgery needles (series from 11 to 24 mm in the MONOCRYL® programme), outside the needle length tolerance of this product, and therefore cannot be declared interchangeable 1:1. There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. Homologous families of poliglecaprone 25 / caprolactone must be reviewed property by property (material, gauge, curvature, point family, length and number of strands, colour, coating and CE/MDR regulatory classification) before any substitution. This needle geometry (DS30, USP 3/0, double thread 2×75 cm) is only fully safely interchangeable within the PREMISUT system itself; always verify in the technical data sheet or IFU of the alternative manufacturer the exact gauge, curvature and needle size, point geometry, number and length of strands, colour and surface treatment before using this information for direct substitution. The cited brands belong to their respective manufacturers and are mentioned only for comparative reference.
5. Selection tips and variants of interest
Tissue to suture: the USP 3/0 gauge (metric EP 2) with a 30 mm needle is the ideal balance between fineness and strength for approximating soft tissues, subcutaneous tissue, skin closures, fascia and ligatures where strength is required during the first 2–3 weeks of healing. The reverse cutting point penetrates dense tissues without tearing the puncture bed and improves the aesthetic outcome. Double-strand format: the 2×75 cm presentation reduces envelope opening per procedure in continuous sutures or with multiple passes, ideal for high-turnover services; if you prefer a single strand, request the 1×75 cm variant of the same DS30 profile (AMP322DS3030). Alternative gauges and needles in the same PGCL range: USP 2/0 in double strand (AMP322DS3020.2) or single strand (AMP322DS3020), DS26 needle in USP 3/0 double strand (AMP322DS2630.2), standard quality in USP 3/0 (AM322DS3030) and DS40 profile in USP 0 (AM322DS4010). Absorption profile: if the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days). Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P322DS3030.2 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.