Description
1. Commercial Introduction
We provide you with the absorbable monofilament poliglecaprone 25 (PGCL) suture from the PREMISUT Prime range, factory reference P322DS4001 (SKU Cahnos AMP322DS4001), in a professional single-strand presentation: colourless grooved thread of 75 cm in USP size 1, mounted on a ⅜ circle needle with a grooved reverse cutting triangular point of 40 mm (DS40 Prime profile).
It is the ideal B2B supply solution for operating theatres, general and digestive surgery departments, gynaecology and purchasing centres looking for a synthetic absorbable thread with exceptional handling, secure knotting, minimal tissue reaction and full batch traceability. Each unit is delivered sterile, ready for immediate use, in a box of 12 individual sterile sachets.
2. Technical explanation of the material and procedure
Poliglecaprone 25 (PGCL) is a synthetic copolymer of poly(glycolic acid 75 % – co-caprolactone 25 %) in an uncoated monofilament structure. Its single-strand design reduces drag (saw effect) during passage through tissue, minimises capillarity and provides excellent handling smoothness and knot security compared with braided multifilaments.
Absorption occurs by controlled hydrolysis over a period of 90 to 120 days (medium absorption), with an approximate retention of original strength of 60 % at 7 days and 30 % at 14 days post-implantation, which comfortably covers the critical healing phase of most soft tissues. It is indicated for soft tissue approximation and general ligation; it is not recommended when prolonged tissue support is required.
The DS40 needle of 40 mm, with ⅜ circle curvature and a grooved reverse cutting triangular point, concentrates the cutting edge on the outer side of the curvature: it penetrates firm, non-distensible tissues (skin, mucous membranes, subcutaneous tissue) with minimal resistance and better aesthetic results, preventing the cut from widening in the puncture bed. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range, grooved needle) |
| Factory reference | P322DS4001 |
| SKU Cahnos | AMP322DS4001 |
| Thread material | Poliglecaprone 25 (PGCL), copolymer 75 % glycolic acid / 25 % ε-caprolactone |
| Structure | Synthetic monofilament, grooved surface |
| Coating | Uncoated |
| Absorption | By hydrolysis, 90–120 days (medium absorption) |
| Tensile strength | Approx. 60 % at 7 days; approx. 30 % at 14 days post-implantation |
| Gauge / Size | USP 1 (metric EP 4) |
| Approximate thread diameter | 0.40 – 0.499 mm (USP Pharmacopeia, absorbable suture) |
| Thread length | 75 cm (1 strand) |
| Thread colour | Colourless (grooved) |
| Needle shape | 3/8 circle (⅜ circular), body and point |
| Tip type | Triangular reverse cutting (Reverse Cutting), grooved |
| Needle size | DS40 Prime (40 mm) |
| Swaged | With needle, 1 needle / 1 thread of 75 cm per unit |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Soft tissue approximation and general ligatures |
| Contraindication | Do not use when extended tissue approximation is required |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
| Storage | Below 30 °C, away from moisture and direct sunlight |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
3.3. Gauge equivalence according to USP/EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 (this product) | 4 | 0.40 – 0.499 mm |
| 2 | 5 | 0.50 – 0.599 mm |
4. Equivalences and Cross-References
Reference P322DS4001 corresponds to the official nomenclature of the PREMISUT Prime range (DS40 profile: ⅜ circle needle with reverse cutting triangular point of 40 mm, USP size 1, colourless grooved thread of 75 cm, single strand) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or bidding.
Poliglecaprone 25 is one of the most standardised medium-absorption synthetic absorbable monofilaments on the market (commercial types MONOCRYL® / MONOCRYL® Plus Antibacterial from Ethicon / J&J MedTech and MONOSYN® / MONOSYN® Quick from B. Braun, in addition to the DemeCAPRONE lines from DemeTECH, Assut Medical, SMI and the PGCL 25 distribution presentations from KeeboMed and Grossmedica). However, no code from another manufacturer combining the exact configuration of this product —USP size 1, DS40 needle of 40 mm, ⅜ circle curvature, reverse cutting triangular point, colourless 75 cm thread and single needle configuration— has been found in official catalogues or regulatory databases (GUDID/EUDAMED). The codes documented in official sources for homologous families with ⅜ circle and reverse cutting needles correspond to short plastic surgery needles (series from 11 to 24 mm of the MONOCRYL® programme), which fall outside the needle length tolerance and cannot be declared 1:1 interchangeable.
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. The homologous poliglecaprone 25 / caprolactone families that must be reviewed property by property (material, size, curvature, point family, length and number of strands, colour, coating and CE/MDR regulatory classification) before any substitution are: Ethicon / J&J MedTech MONOCRYL® and MONOCRYL® Plus Antibacterial, B. Braun MONOSYN® / MONOSYN® Quick and PGCL distribution lines (KeeboMed, Grossmedica). This needle geometry (DS40, USP 1, 75 cm, single needle) is only fully safely interchangeable within the PREMISUT system itself; always verify in the technical data sheet or IFU of the alternative manufacturer the exact size, curvature and needle measurement, point geometry, length and number of strands, colour and surface treatment before using this information for direct substitution.
5. Selection tips and variants of interest
Tissue to be sutured: USP size 1 (EP 4) offers high tensile strength for subcutaneous tissue, fasciae and soft tissues with medium-high tension; the reverse cutting point penetrates dense tissues without tearing the puncture bed and improves the aesthetic result.
Quality and presentation: this reference is single-strand (1×75 cm) in Prime quality. If you prefer an economical alternative with the same geometry, the standard version AM322DS4001 (322DS4001) is available; if the procedure requires continuous or multi-point sutures without re-threading, the double-thread variant AMP322DS4001.2 (P322DS4001.2, 2×75 cm) reduces the number of sachets opened per procedure.
Alternative sizes on the same DS40 needle: USP 0 in single strand (AMP322DS4010) or in double thread (AMP322DS4010.2), as well as the standard version AM322DS4010. For finer sizes or shorter needles, consult the DS30 family of the same PGCL range.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each procedure, retain the reference P322DS4001 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial brands, contact the technical-commercial team at Cahnos.





Reviews